Preferred Language
Articles
/
ijp-221
Microwave losses of nanostructure Li-Ni ferrites in X-band and Ku-band
...Show More Authors

The molar ratio(x) of Li-Ni ferrites in the formula Li0.5-0.5xNixFe2.5-
0.5xO4 was varied in range 0.1-1.0 by hydrothermal process. The
XRD, SEM, and TEM tests were conducted to examine the samples
crystalline phase and to characterize the particles shapes and sizes.
The high purity spinel structure was obtained at med and high x
values. SEM and TEM images showed the existence of different
ferrite particles shapes like nanospheres and nanorods. The
maximum particle size is around (20nm). These size encourage
occurrence of super paramagnetic state. The reflection loss and
insertion loss as microwave losses of Li-Ni ferrite-epoxy composite
of 1mm thickness and mixing ratio 39.4 wt was investigated. The
minimum reflection loss in x-band and in Ku band was about -8dB
around 10GHz and lower than -18dB respectively. The insertion loss
exceeded -6dB in the two band for some samples.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Chemical Methodologies
A Novel Design for Gas Sensor of Zinc Oxide Nanostructure Prepared by Hydrothermal Annealing Technique
...Show More Authors

Scopus (12)
Scopus
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Nanostructural study of Ti-Ni binary alloy prepared by mechanical alloying
...Show More Authors

In the present study, a powder mixture of elements Ti and Ni was mechanically alloyed in a high energy ball mill. Microstructure of the nanosized amorphous milled product in different stages of milling has been characterized by X- ray diffraction, scanning electron microscopy and differential thermal analysis. We found that time of mechanical alloying is more significant to convert all crystalline structure to the amorphous phase. Nanocrystalline phase was achieved as a result of the mechanical alloying process. The results also indicates that the phase transformation and the grain size occurs in these alloys are controlled by ball milling time

View Publication Preview PDF
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study of New Re-Ni-Mo/Al2o3 and Conventional Hydrodesulphurization Catalyst
...Show More Authors

New types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparative Study of New Re-Ni-Mo/Al2o3 and Conventional Hydrodesulphurization Catalyst
...Show More Authors

New types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3 catalyst. The results showed that Re-Ni-Mo/ γ-Al2O3 have more activity in desulfurization than Ni-Mo//γ-Al2O3

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 22 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
B(Ml) and (I1 II f<MJ) II li) for one and two bodies of even-even Ba(A=l30-136) isotopes using IBM-1
...Show More Authors

In   the   present    work    the    nuclear    structure   of   even-even

Ba(A=130-136,   Z=56)  isotopes   was  studied   using  (IBM-1).  The reduced matrix  element of magnetic dipole moment  (11  II f(Ml) II/,) and the magnetic dipole transitions probability B(M 1) were calculated

for one and two bodies of even-even Ba(A=lJ0-136, Z=56). A good

agreement had been found of present with available experimental  data.

View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Comparison between Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in the Detection of Osteoporosis in Postmenopausal Women
...Show More Authors

Background: Osteoporosis is denoted by low bone mass and microarchitectural breakdown of bone tissue, directing to increased fracture risk and bone fragility. Fractures may lead to a decreased quality of life and increased medical costs. Thus, osteoporosis is widely considered a significant health concern.

Objective. This study aimed to compare quantitative computed tomography (QCT) and dual-energy X-Ray absorptiometry (DXA) to detect osteoporosis in postmenopausal women.

Subjects and Methods. We measured spinal volumetric bone mineral density (BMD) with QCT and areal spinal and hip BMD with DXA in 164 postmenopausal women. We calculated the osteo

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
A study of the safety and security conditions followed in the X-ray clinics in the Al-Amiriya-Baghdad
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jul 15 2008
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
riol] and its Complexes with Co", Ni 9, Cu º, and Znº.
...Show More Authors

The reaction of 2, 4, 6-trihydroxyactophenonemonohydrate with hydrazine monohydrate was realized under reflux in methanol and a few drops of glacial acetic acid were added to give the (intermediate) 2-(1-hydrazono-ethyl)-benzene-1, 3, 5-triol, which reacted with salicylaldehyde in methanol to give a new type (NO) ligand [HL][(2-1-[(2-hydroxy-benzyliidene)-hydrazono]-ethyl) benzene-1, 3, 5-triol. The ligand was reacted with Mcl.(where M-Co, Ni, Cu, and Zn) under reflux in methanol with (l: 1) ratio to give complexes of the general formula [M (HL)]. All compounds have been characterized by spectroscopic methods I" H NMR, IR. UV-Vis, HPLC, atomic absorption] microanalysis along with conductivity measurement. From the above data the proposed mo

... Show More
Publication Date
Fri Feb 28 2020
Journal Name
Neuroquantology
Using X-Ray Films for Evaluation efficiency of Unsaturated Polyester Reinforced by Lead Oxide as Shielding for Medical X-ray Devices
...Show More Authors

The largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase

... Show More
View Publication
Scopus Crossref