This work aim to prepare Ag/R6G/PMMA nanocomposite thin
films by In-situ plasma polymerization and study the changes in the
optical properties of fluorophore due to the presence of Ag
nanoparticles structures in the vicinity of the R6G laser dye. The
concentrations of R6G dye/MMA used are: 10-4M solutions were
prepared by dissolving the required quantity of the R6G dye in
MMAMonomer. Then Silver nanoparticles with 50 average particles
size were mixed with MMAmonomer with concentration of 0.3, 0.5,
0.7wt% to get R6G silver/MMA in liquid phase. The films were
deposited on glass substrates by dielectric barrier discharge plasma
jet. The Ag/R6G/PMMA nanocomposite thin films were
characterization by UV-Visible absorption spectra by using a double
beam UV-Vis-NIR Spectrophotometer and fluorescence
Spectrophotometer. The thin films surface morphological analysis is
carried out by employing an AFM and SEM. the structure analysis
are achieved by X-ray diffraction. The thickness of the films was
measured by optical interferometric method. AFM analysis shows
that the surface roughness of plasma polymerized pure PMMA thin
films was 2.7 nm and for (10-4 R6G + 0.7wt% Ag)Ag/R6G/PMMA
thin films was 4.16 nm. The SEM images were indicates that Ag
nanoparticles (NPs) disperse in the PMMA matrix with uniform
distribution and formed mostly spherical NPs and slightly
agglomerate. Also the silver nanoparticles with 0.7wt%
concentration enhances the absorption process by 2.3 times and the
fluorescence by 1.7 times. it can be conclude, that the addition of low
concentrations of silver nanoparticles to the PMMA/ R6G matrix was
changing the optical properties of the prepared nanocomposite thin
films.
Abstract
This paper presents an intelligent model reference adaptive control (MRAC) utilizing a self-recurrent wavelet neural network (SRWNN) to control nonlinear systems. The proposed SRWNN is an improved version of a previously reported wavelet neural network (WNN). In particular, this improvement was achieved by adopting two modifications to the original WNN structure. These modifications include, firstly, the utilization of a specific initialization phase to improve the convergence to the optimal weight values, and secondly, the inclusion of self-feedback weights to the wavelons of the wavelet layer. Furthermore, an on-line training procedure was proposed to enhance the control per
... Show MorePhotonic crystal fiber interferometers (PCFIs) are widely used for sensing applications. This work presented solid core-PCFs based on Mach-Zehnder modal interferometer for sensing refractive index. The general structure of sensor was applied by splicing short lengths of PCF in both sides with conventional single mode fiber (SMF-28).To apply modal interferometer theory collapsing technique based on fusion splicing used to excite higher order modes (LP01 and LP11). A high sensitive optical spectrum analyzer (OSA) was used to monitor and record the transmitted wavelength. This work studied a Mach-Zahnder interferometer refractive index sensor based on splicing point tapered SMF-PCF-SMF. Relation between refractive index sensitivity and tape
... Show MorePrediction of the formation of pore and fracture pressure before constructing a drilling wells program are a crucial since it helps to prevent several drilling operations issues including lost circulation, kick, pipe sticking, blowout, and other issues. IP (Interactive Petrophysics) software is used to calculate and measure pore and fracture pressure. Eaton method, Matthews and Kelly, Modified Eaton, and Barker and Wood equations are used to calculate fracture pressure, whereas only Eaton method is used to measure pore pressure. These approaches are based on log data obtained from six wells, three from the north dome; BUCN-52, BUCN-51, BUCN-43 and the other from the south dome; BUCS-49, BUCS-48, BUCS-47. Along with the overburden pressur
... Show MoreMedication safety is an important part of the comprehensive patient safety term. Medication safety is gaining more attention as the World Health Organization set the goal of decreasing medication harm by (50%) for the next 5 years when launching the third global challenge. Studying medication safety in the risk groups such as young ages, children are crucial to learn more about the effect of medicines in this risk group since they are not included in the clinical trials. Adverse drug reaction is defined as any harm resulted from the drug itself during medical process journey, while medication errors are any harm resulted from the treatment process rather than the drug or it is the result of the failure in a step of the treatment process
... Show MoreIn this research, the influence of the orientation and distance factors on the lowest usable frequency (LUF) parameter has been studied theoretically. The calculations of the (LUF) parameter have been made using the (VOACAP) international communication model for the connection links between the capital Baghdad and many other locations that distributed on different distances and directions over the Middle East region. The results shown in this study indicate there is a slight affection of the link direction (orientation) on the LUF parameter, while the influence of the distance factor is more significant on the values of the LUF parameter. The day/night effect appears for the long distance HF links (i.e. more than a 500 Km)
Background: Laparoscopic cholecystectomy has many difficulties which include port Insertion, Dissectionof the Calot’s Triangle , Grasping of the Gallbladder , Wall thickness, Adhesion and extraction of theGallbladder. Aim of the Study: To predict how difficult cholecystectomy will be from assessing the patientpreoperatively which, in turn, help in decreasing the risks on the patients and preventing post-operativecomplications. Patients and Methods: A prospective study conducted in the department of General Surgeryat Al-Ramadi Teaching Hospital for the period of nine months from 15th of May 2018 till the 15th of February2019. It included 60 patients, all of them were undergone laparoscopic cholecystectomy for Gallstone. Patientswit
... Show More<span lang="EN-US">The need for robotics systems has become an urgent necessity in various fields, especially in video surveillance and live broadcasting systems. The main goal of this work is to design and implement a rover robotic monitoring system based on raspberry pi 4 model B to control this overall system and display a live video by using a webcam (USB camera) as well as using you only look once algorithm-version five (YOLOv5) to detect, recognize and display objects in real-time. This deep learning algorithm is highly accurate and fast and is implemented by Python, OpenCV, PyTorch codes and the Context Object Detection Task (COCO) 2020 dataset. This robot can move in all directions and in different places especially in
... Show MoreSmishing is the delivery of phishing content to mobile users via a short message service (SMS). SMS allows cybercriminals to reach out to mobile end users in a new way, attempting to deliver phishing messages, mobile malware, and online scams that appear to be from a trusted brand. This paper proposes a new method for detecting smishing by combining two detection methods. The first method is uniform resource locators (URL) analysis, which employs a novel combination of the Google engine and VirusTotal. The second method involves examining SMS content to extract efficient features and classify messages as ham or smishing based on keywords contained within them using four well-known classifiers: support vector machine (SVM), random
... Show MoreThe research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.
The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.