Preferred Language
Articles
/
ijp-203
Performance of humidity sensor based on photonic crystal fiber interferometer
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are greatly used
for sensing applications. This work presents the fabrication and
characterization of a relative humidity sensor based on Mach-
Zehnder Interferometer (MZI), which operates in reflection mode.
The humidity sensor operation based on the adsorption and
desorption of water vapour at the silica-air interface within the PCF.
The fabrication of this sensor is simple, it only includes splicing and
cleaving the PCF with SMF.PCF (LMA-10) with a certain length
spliced to SMF (Corning-28).
The spectrum of PCFI exhibits good sensitivity to humidity
variations. The PCFI response is observed for a range of humidity
values from (27% RH to 85% RH), the position of the interference
peaks is found to be shifted to longer wavelength with humidity
increasing. In this work, a different length of PCFs are used, and the
maximum humidity sensitivity of (5.86 pm / %RH) is achieved with
(4.5cm) PCF length, and the rise time of (8sec) is achieved. This
humidity sensor has distinguished features as that it does not require
the use of a hygroscopic material, robust, compact size, immunity to
electromagnetic interference, and it has potential applications for
high humidity environments.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Acetic acid concentration estimation using plastic optical fiber sensor based surface Plasmon resonance
...Show More Authors

Optical fiber chemical sensor based surface Plasmon resonance for sensing and measuring the refractive index and concentration for Acetic acid is designed and implemented during this work. Optical grade plastic optical fibers with a diameter of 1000μm were used with a diameter core of 980μm and a cladding of 20μm, where the sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal and the Acetic acid is placed on the sensing probe.

View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Design of Tunable Optical Band Pass Filter based on in-Line PM-Mach Zehnder Interferometer
...Show More Authors

In this paper, tunable optical band-pass filters based on Polarization Maintaining Fiber –Mach Zehnder Interferometer presented. Tunability of the band-pass filter implemented by applying different mechanical forces N on the micro-cavities splicing regions (MCSRs). The micro-cavity formed by using three variable-lengths of single-mode polarization-maintaining fiber with (8, 16, 24) cm lengths, splice between two segments of (SMF-28) with (26, 13) cm lengths, using the fusion splicing technique.  Ellipsoidal shape micro-cavities experimentally achieved parallel to the propagation axis having dimensions between (12-24) μm of width and   (4-12) μm of length. A micro-cavity with width and length as high as 24 μm and 12 μ

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Ssrn Electronic Journal
Highly Sensitive Fiber Brag Grating Based Gas Sensor Integrating Polyaniline Nanofiber for Remote Monitoring
...Show More Authors

View Publication
Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Optical Fiber Technology
Highly sensitive fiber Bragg grating based gas sensor integrating polyaniline nanofiber for remote monitoring
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Tunable Optical filters Using Etched Polarization Maintaining Fiber Hybrid Sagnac Interferometer
...Show More Authors

: In modern optical communication system, noise rejection multiple access interference (MAI) must be rejected in dense access network (DAN). This paper will study the dual optical band pass and notch filters. They will be extracted with tunable FWHM using 10cm (PMF) with different cladding diameters formed with etching 125μm PMF after immersing it with 40% of hydrofluoric acid (HF). This fiber acts as assessing fiber to perform Sagnac interferometer with splicing regions that placed 12cm (SMF) for performing hybrid Sagnac interferometer that consists of Mach-Zehnder instead of Sagnac loop which is illuminated by using laser source with centroid wavelength of 1546.7nm and FWHM of 286 pm or 9 ns in the time domain. . Firs

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Designing and Constructing the Strain Sensor Using Microbend Multimode Fiber
...Show More Authors

The microbend sensor is designed to experience a light loss when force is applied to the sensor. The periodic microbends cause propagating light to couple into higher order modes, the existing higher order modes become unguided modes. Three models of deform cells are fabricated at (3, 5, 8) mm pitchand tested by using MMF and laser source at 850 nm. The maximum output power of (8, 5, 3)mm model is (3, 2.7, 2.55)nW respectively at applied force 5N and the minimum value is (1.9, 1.65, 1.5)nW respectively at 60N.The strain is calculated at different microbend cells ,and the best sensitivity of this sensor for cell 8mm is equal to 0.6nW/N.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Dual Measurements of Pressure and Temperature With Fiber Bragg Grating Sensor
...Show More Authors

Abstract

The fiber Bragg grating (FBG) technology has been rapidly applied in the sensing technology field. In this work, uniform FBG was used as pressure sensor based on measuring related Bragg wavelength shift. The pressure was applied directly by air compressor to the sensor and the pressure was ranged from 1 to 6 bar.

      This sensor also was affected by the external temperature so as a result it could be used as a temperature sensor. This sensor could be used to monitor the pressure of dams. It has been shown from the result that the sensor is very sensitive to the pressure and the sensitivity was (67 pm\bar) and is very sensitive to temperature and the sensitivity was (10p

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Laser
Propanol Vapor Sensor Utilizing Air-Gap as Sensing Part of the Mach-Zehnder Interferometer
...Show More Authors

The purpose of this study is to demonstrate a simple high sensitivity vapor sensor for propanol ((CH3)2CHOH). A free space gap was employed in two arms of a Mach-Zehnder interferometer to serve as the sensing mechanism by adding propanol volume (0.2, 0.4, 0.6, 0.8, and 1) ml and to set the phase reference with a physical spacing of (0.5, 1, 1.5, and 2) mm. The propagation constant of transmitted light in the Mach-Zehnder interferometer’s gap changes due to the small variation in the refractive index inside sensing arm that will further shift the optical phase of the signal. Experimental results indicated that the highest sensitivity of propanol was about 0.0275 nm/ml in different liquid volume while highest phase shift was 0.182×103 i

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Determine, Predict and Map Soil pH Level by Fiber Optic Sensor
...Show More Authors
Abstract<p>Soil pH is one of the main factors to consider before undertaking any agricultural operation. Methods for measuring soil pH vary, but all traditional methods require time, effort, and expertise. This study aimed to determine, predict, and map the spatial distribution of soil pH based on data taken from 50 sites using the Kriging geostatistical tool in ArcGIS as a first step. In the second step, the Support Vector Machines (SVM) machine learning algorithm was used to predict the soil pH based on the CIE-L*a*b values taken from the optical fiber sensor. The standard deviation of the soil pH values was 0.42, which indicates a more reliable measurement and the data distribution is normal.</p> ... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Thu Apr 29 2021
Journal Name
Iraqi Journal Of Science
Capacitance and Resistivity Measurements of Polythiophene /Metallic Nanoparticles-based Humidity Sensors
...Show More Authors

Capacitive–resistive humidity sensors based on polythiophene (P3HT) organic semiconductor as an active material hybrid with three types of metallic nanoparticles (NP) (Ag, Al, and Cu) were synthesized by pulsed laser ablation (PLA). The hybrid P3HT/metallic nanoparticles were deposited on indium-tin-oxide (ITO) substrate at room temperature. The surface morphology of theses samples was studied by using field emission scanning electron micrographs (FE-SEM), which indicated the formation of nanoparticles with grain size of about 50nm. The electrical characteristics of the sensors were examined as a function of the relative humidity levels. The sensors showed an increase in the capacitance with variation in the humidity level.  While

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref