In the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.
A method was developed that offers a rapid, simple and accurate technique for the determination of chlorophenols at trace levels in aqueous samples with very limited volumes of organic solvents. These compounds were acetylated, then preliminarily extracted with n-hexane. The enriched chlorophenols were directly analyzed using gas chromatography with an electron-capture detector. The detection limits were in the range of 0.001–0.005 mg/L, except for 2-chlorophenol, which was always above 0.013 mg/L. Relative standard deviation for the spiked water samples ranged from 2.2 to 6.1%, while relative recoveries were in the range of 67.1 to 101.3%.
Radon concentrations are measured for water samples collected from twenty wells which were drilled in Hashimiya area in addition to twelve samples of surface water using Alpha Gaurd. 140 samples, 7 for each well, were collected represent wet season in continuous pumping and 20 samples, one for each well, were collected represent dry season. Concentration of radon in groundwater is many times of its concentration in surface water. The minimum concentration in groundwater is about (7) Bq/L and (5) Bq/L while the maximum concentration is about (31) Bq/L and (19) Bq/L in wet season and dry season respectively. The range of radon concentrations in river water is between (1.06) Bq/L and (1.21) Bq/L. This study has indicated that there is a flo
... Show MoreIn this research, an analysis for the standard Hueckel edge detection algorithm behaviour by using three dimensional representations for the edge goodness criterion is presents after applying it on a real high texture satellite image, where the edge goodness criterion is analysis statistically. The Hueckel edge detection algorithm showed a forward exponential relationship between the execution time with the used disk radius. Hueckel restrictions that mentioned in his papers are adopted in this research. A discussion for the resultant edge shape and malformation is presented, since this is the first practical study of applying Hueckel edge detection algorithm on a real high texture image containing ramp edges (satellite image).
Twelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U238 and series Th232 in addition to K40 in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K40, series U238, series Th232
The determination of critical micelle concentration of selected non-ionic surfactants (Tween 20,40 and 80) have been investigated using magnetic water(MW)as an aqueous medium.Conductometry technique is used to determine critical micelle concentration.The effect of alcohol addition and temperature variation at the range(293.15 -303.15K) are also pursued. It is concluded that the process of micellization is spontaneous and endothermic because of the observed free energy of micellization (ΔGom) , enthalpy change of micellization (ΔHom), and entropy change of micellization (ΔSom) for the system was also studied.The properties of the non-ionic surfactants were studied, both in absence and presence of
... Show More???? ?? ??? ????? ???? ?????? ?????????? ????? ??????? ???? ?????? ????? ??? ??? ????? ?? ???? ??? ????? ????? ???? ????? ????? ?? 0-3cm, 10cm, 20cm, 30cm, 40cm ???????? ????? ?? ???? ????? ???????? ?? ???? ????? ?????? CR-39??????? ?? ??? ??? ?????????? ???????????? ???????? ???? n.cm-2.s-1 5 x 103?? ?????? ?????????? Am241- Be??? ???? ??????? ????????? ??? ?? ???? ????? ?????????? ??? ?? ????? ??????? ?????? 0.881±0.086??? ?? ??????? ????? ??? ????? ??? ?? ????? ????? ??? ???????? ???0.441±0.036 ??? ?? ???????
In this study, depleted uranium concentrations were calculated in sediments Diyala River samples , where 14 samples of sediment along the Diyala River were collected , starting from the Rustumiya area and ending with the Tuwaitha area after its confluence with the River Tigris , using the solid - state nuclear track detectors technique (SSNTDs). We found that the highest concentration of depleted uranium was in the sample (A-13), and was taken from the Tuwaitha area with the specific activity of the amount (78.1 ± 8.5 Bq/kg ) and the lowest concentration of the depleted uranium was in the sample (A-7), and was taken from the Azwaip area with the
... Show MoreThe aim of this work is to determine the uranium concentration in soil samples
taken from the north, south, east, west and center of the city of Baghdad and
measure its impact on the rate of cell division for non-smokers peoples and living in
those areas and that between the ages 25-30 year.
The uranium concentration in the samples determined by using CR-39 track
detector . As calculated for the ten samples of each site when irradiated by thermal
neutrons from the (Am - Be) source with flux (5x 103 n S-1cm-2), the concentration
values were calculated by a comparison with standard geological samples. The
results indicate that the extent of the concentration of uranium in the soil north and
east of Baghdad was 12
The optical detectors which had been used in medical applications, and especially in radioactive treatments, need to be modified studied for the effects of radiations on them. This study included preparation of the MnS thin films in a way that vacuum thermal evaporation process at room temperature 27°C with thickness (400+-10nm) nm and a sedimentation rate of 0.39nm/sec on glass floors. The thin films prepared as a detector and had to be treated with neutron irradiation to examine the results gained from this process. The results decay X-ray (XRD) showed that all the prepared thin films have a multi-crystalline structure with the dominance of the direction (111), the two samples were irradiated with a neutron irradiation source (241Am-9Be)
... Show MoreIn this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m3, 23.27±13.57 Bq/m3, and 10.67±4.14 Bq/m3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest ave