Preferred Language
Articles
/
ijp-188
Plasma characteristics of Ag:Al alloy produced by fundamental and second harmonic frequencies of Nd:YAG laser
...Show More Authors

In this work, the spectra for plasma glow produced by pulse
Nd:YAG laser (λ=532 and 1064nm) on Ag:Al alloy with same molar
ratio samples in distilled water were analyzed by studying the atomic
lines compared with aluminum and silver strong standard lines. The
effect of laser energies of the range 300 to 800 mJ on spectral lines,
produced by laser ablation, were investigated using optical
spectroscopy. The electron temperature was found to be increased
from 1.698 to 1.899 eV, while the electron density decreased from
2.247×1015 to 5.08×1014 cm-3 with increasing laser energy from 300
to 800 mJ with wavelength of 1064 nm. The values of electron
temperature using second harmonic frequency are greater than of
1064 nm, which increased from 2.405 to 2.444 eV, while the electron
density decreased from 2.210×1015 to 1.516×1015 cm-3 with
increasing laser energy for the same energy range.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 08 2022
Journal Name
V. International Scientific Congress Of Pure, Applied And Technological Sciences
The effect of background vacuum pressure on the length of gas discharge plasma by using Aluminum electrodes
...Show More Authors

Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.

Publication Date
Tue Sep 01 2020
Journal Name
Clinical Plasma Medicine
Breast cancer treatment using cold atmospheric plasma generated by the FE-DBD scheme
...Show More Authors

Background Cold atmospheric plasma (CAP) is widely used in the cancer therapy field. This type of plasma is very close to room temperature. This paper illustrates the effects of CAP on breast cancer tissues both in vivo and in vitro. Methods The mouse mammary adenocarcinoma cell line AN3 was used for the in vivo study, and the MCF7, AMJ13, AMN3, and HBL cell lines were used for the in vitro study. A floating electrode-dielectric barrier discharge (FE-DBD) system was used. The cold plasma produced by the device was tested against breast cancer cells. Results The induced cytotoxicity percentages were 61.7%, 68% and 58.07% for the MCF7, AMN3, and AMJ13 cell lines, respectively, whereas the normal breast tissue HBL cell line exhibited very li

... Show More
View Publication
Scopus (50)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Study the effect by CO2 laser on some optical properties of (Cd) thin film doping by Ni
...Show More Authors

In this research study the effect of irradiation by (CW) CO2 laser on some optical properties of (Cds) doping by Ni thin films of (1)µm thickness has been prepared by heat evaporation method. (X-Ray) diffraction technique showed the prepared films before and after irradiation are ploy crystalline hexagonal structure, optical properties were include recording of absorbance spectra for prepared films in the range of (400-1000) nm wave lengths, the absorption coefficient and the energy gap were calculated before and after irradiation, finally the irradiation affected (CdS) thin films by changing its color from the Transparent yellow to dark rough yellow and decrease the value absorption coefficient also increase the value of energy gap.

View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Argon plasma needle source
...Show More Authors

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Synthesis and characterizations of core-shell SiO2/Au/Ag nano-particles by exploding of wire and pulsed laser plasmas
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Electronically Implementation and Detection of Pulse Laser from Continuous Laser Diode
...Show More Authors

This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of non-thermal plasma by FE-DBD scheme on lipids in blood in vivo study
...Show More Authors

This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.

View Publication
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Aes-atema International Conference Series - Advances And Trends In Engineering Materials And Their Applications
Effect of new tool geometry on weld strength of AA2024 aluminum alloy plates welded by friction stir spot welding process
...Show More Authors

A new tool geometry was used to achieve friction stir spot welding (FSSW) in which the shoulder was designed separately from the rotating pin, and in order to examine weldment strength through the modified tool, a lap joints of AA2024 aluminum alloy plate 1 mm thick were welded successfully by using 6 mm pin diameter and varying process parameters (rotational speeds, tool nose geometry, and depth of tool penetration in the lower welded plate). Experimental tests indicate that the maximum average tensile shear load was 3100 N at the best selected condition. Microstructure examination and micro hardness test along the spot zones were investigated as well as measuring pin penetration load. Visual inspection of the welded spot surface shows a g

... Show More
Scopus
Publication Date
Fri Jun 30 2023
Journal Name
College Of Islamic Sciences
The strategy of applying quality indicators to educational outcomes according to market requirements - a fundamental study
...Show More Authors

 

A research study in which a methodology for quality indicators that can be adopted to evaluate the educational process in educational institutions within a specific strategy helps individuals in charge of educational education to make appropriate decisions based on accurate and properly approved plans to achieve successful outcomes.

These indicators can be used to judge the quality of educational institutions in order to improve, improve and develop them. This study has concluded the necessity of putting quality into actual application in order to benefit from it in evaluating the future action of Iraqi educational institutions.

The external changes brought about by technology and family life have made the

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 27 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Quality and cost characteristics of tourist
...Show More Authors

The tourism services provided in the hotel organizations are a set of material and moral elements that represent tourist attractions that are offered to the guests in order to satisfy their needs and desires are accommodation, food, drink and other facilities to reach the satisfaction and satisfaction of guests.Where these tourist services need a mechanism to ensure their quality by working to identify and calculate the costs of these services properly and accurately with the attempt to referendum and reduce the waste and loss to reduce these costs while providing the finest types of tourism services by calculating the cost of production and the administration seeks to reduce Non-essential activities through hotel activities that add val

... Show More
View Publication Preview PDF
Crossref