The specific activity of 29 soil samples collected from Fuel
Fabrication Facility FFF at AL-Tuwaitha site, 20 km south of
Baghdad were determined using HPGe detector in a low background
configuration, it's relative efficiency of 40%, and resolution of 2keV
for the 1332 keV gamma ray emission of 60Co. The range of activity
concentrations of 226Ra, 232Th and 40K were between (12.56-31.96),
(10.2-18.4) and (47.47-402.1) Bq/kg respectively. In order to assess
any radiological hazard to human health, the absorbed gamma dose
rate D in air at 1m above the ground surface was calculated in the
range (18.87 to 36.46) nGy/h; the outdoor annual effective dose
equivalent AEDE was evaluated to vary from 0.0039 to 0.0076
mSv/y with the mean value 0.0059 mSv/y, this value comparable to
the worldwide effective dose 0.48mSv/y. The Radium Equivalent
Raeq for all samples were evaluated and were lower than the accepted
safety limit value of 370 Bq/kg. The results indicated that the
radiation of hazards from primordial radionudlides in all samples in
this study is not significant.
Background: Hashimoto's thyroiditis has been found to coexist with differentiated thyroid cancer in surgical specimens, but an association between the two conditions has been discounted by the medical literature. So, we performed this research to determine any potential relationship between Hashimoto's thyroiditis and the risk of developing differentiated thyroid cancer in clinical status. we assessed the related clinical factors linking these conditions, especially serum thyroid-stimulating hormone concentration, family history of thyroid disease, gender& young age group. Aim of study: to determine that hashimoto’s thyroiditis increases risk for differentiated thyroid carcinoma. Patients and method: This study is a Cross-sectiona
... Show MoreBackground: Febrile convulsions are the most frequent type of seizures in children under 6 years of age. Significant percentage of these children will later suffer from recurrence of febrile convulsion.Objectives: To identify the main risk factors for recurrent febrile convulsions in children.Methods: we carried out a case control study involving 89 children those who experienced first attack of febrile convulsions and 92 children with recurrent attack of febrile convulsions. The study was conducted in Central Children Teaching Hospital, Baghdad during the period 2006- 2007. Results: Compared to children with first attack of febrile convulsion, children with recurrent seizures were younger at onset (4- 12m) (67% vs. 44%), mainly male (70
... Show MoreThe aim of this research is to demonstrate the impact of credit risk on the banks of the study sample on the granting of loans and credit facilities, and try to reduce the size of credit risk to banks as a result of granting loans and credit facilities, credit risk is the oldest form of risk in financial markets. Every financial institution takes a degree of risk when it gives loans and credit facilities to companies and customers, It is exposed to financial losses when some borrowers fail to repay their loans as agreed, and at the same time credit facilities are the most profitable operations of the bank as it is the most profitable banking operations than other operations, so it represents the research communit
... Show MoreIn order to reduce the environmental pollution associated with the conventional energy sources and to achieve the increased global energy demand, alterative and renewable sustainable energy sources need to be developed. Microbial fuel cells (MFCs) represent a bio-electrochemical innovative technology for pollution control and a simultaneous sustainable energy production from biodegradable, reduced compounds. This study mainly considers the performance of continuous up flow dual-chambers MFC
fueled with actual domestic wastewater and bio-catalyzed with anaerobic aged sludge obtained from an aged septic tank. The performance of MFCs was mainly evaluated in terms of COD reductions and electrical power output. Results revealed that the C
The current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless steel
... Show MoreIn this study, a one-dimensional model represented by Butler-Volmer-Monod (BVM) model was proposed to compute the anode overpotential and current density in a mediator-less MFC system. The system was fueled with various organic loadings of real field petroleum refinery oily sludge to optimize the favorable organic loading for biomass to operate the suggested system. The increase in each organic loading showed higher resistance to electrons transport to the anode represented by ohmic loss. On the contrary, both activation and mass transfer losses exhibited a noticeable decrement upon the increased organic loadings. However, current density was improved throughout all increased loads achieving a maximum current density of 5.2 A/m3
... Show MoreThe current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless st
... Show More