Preferred Language
Articles
/
ijp-164
Determination the concentrations of radon gas and exhalation rate in some phosphate fertilizer using CR-39 track detector
...Show More Authors

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 22 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Assessment of Some Serum Biomarkers of Fibromyalgia Syndrome in Pre and Postmenopausal Women in Relation to Obesity
...Show More Authors

The objective of this study is to evaluate the level of parathyroid hormone, Co enzyme Q and total antioxidant status in serum’s women with fibromyalgia syndrome firstly, then to demonstrate if these biochemical markers affected by age and obesity.

      This study was performed at Rheumatology and Rehabilitation Consultation Unit in Baghdad Teaching Hospital. Venous blood sample were drawn from (59) female with FMS and (30) control (without FMS). The serum was obtained after on standing in order to coagulate then centrifuged. The mean age± SD of FMS group was (42.22±15.34) years and for control was (40.7±18.22) years. Those participants were subdivided into four different groups acc

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Synthesis of several Urea plast Resins using Different Aldehydes Preparation of some Alkyde Resins and Empolyment of the prepared Resins as Additives for AZO Dyes
...Show More Authors

Urea formaldehyde resin was prepared by using basic media by yield 95%. The Remaining of ureaplasts resin were prepared in acetic acid media by high yield. Alkyde resins were prepared by condensation polymerization by react Succinic, Maleic, Phthalic anhydrides with Ethylene glycol or Glycerol. Select samples of the prepared alkyde resins were mixed with Azo dyes in special ratio. The mixtures were used as coatings for wood, and compaised with pure dyes. The Coating that some alkyde resins showed better adhesion from using dyes alone. Preparation of wood coating by mixing ureaplast resins and alkyde resins with Azo dyes in special ratios. The coating showed better adhesion, brighter colors and better resistance to heat from Preceding coat

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Solvent Extraction And Spectrophotomteric Determination Of Cu(Ii) With Dicyclohexyl - 18- Crown-6
...Show More Authors

Liquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Comparative Study of Hepcidin and Some Inflammatory Parameters in Pregnant Women at the Three Trimesters
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Nov 14 2025
Journal Name
Euphrates Journal Of Agricultural Science
PHYSIOLOGICAL INFLUENCEOFNITROGENFERTILIZERS RESOURCESANDANTI-TRANSPIRATININ SOME QUALITY ATTRIBUTES AND THE CONCENTRATION OF NITRATES IN POTATO TUBERS
...Show More Authors

View Publication
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The Influence of Ramadan Fasting on Some Hematological and Biochemical Parameters in Healthy Adult Males
...Show More Authors

Objective(s): Ramadan is the Holy month of the Muslims, where they are required to abstain from food and drinks
from dawn till the beginning of night. This study was conducted in Ramadan to investigate the effect of fasting on
hematological incidences, lipid profile, renal and liver function tests among healthy adult males.
Methodology: The present study was carried out in Ramadan – 1431 of Higira (August-September 2010). The study
sample was 56 healthy adult males. Five samples of blood were taken at five intervals (Before, at day 1, 15, 28 and
after Ramadan). Estimation was done for hematological markers, (hemoglobin, white blood cells count, platelet
count); renal function tests (blood urea, serum uric acid, serum

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 30 2018
Journal Name
Journal Of Materials Science: Materials In Electronics
H2S gas sensitivity of PAni nano fibers synthesized by hydrothermal method
...Show More Authors

In this work, PAni nanofibers (NFs) are successfully synthesized via hydrothermal method. The structural, surface morphological, optical, electrical and H2S gas sensing properties have been investigated for PAni thin films deposited by spin coating technique. The XRD pattern reveals crystalline nature of PAni NFs with crystallite size of 9.2 nm. The SEM image of Polyaniline clearly indicates that the polymer possesses nanofiber like structure. The optical properties show that the optical energy gap follows allowed direct electronic transition calculated using Tauc’s equation. Intense hotoluminescence (PL) peaks at 309, 340 and 605 nm are observed. The electrical properties such as D.C. conductivity and Hall effect have been studied wher

... Show More
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Enhancement of vanadium oxide doped Eu+3 for gas sensor application
...Show More Authors

Thin films of vanadium oxide nanoparticles doped with different concentrations of europium oxide (2, 4, 6, and 8) wt % are deposited on glass and Si substrates with orientation (111) utilizing by pulsed laser deposition technique using Nd:YAG laser that has a wavelength of 1064 nm, average frequency of 6 Hz and pulse duration of 10 ns. The films were annealed in air at 300 °C for two hours, then the structural, morphological and optical properties are characterized using x-ray diffraction (XRD), Field emission scanning electron microscopy (FESEM) and UV-Vis spectroscopy respectively. The X-ray diffraction results of V2O5:Eu2O3 exhibit that the film has apolycrystalline monoclinic V2O5 and triclinic V4O7 phases. The FESEM image shows a h

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Gas sensing performance of Sol-gel grown NiO-doped Cr2O3 nanoparticles
...Show More Authors

The sensors based on Nickel oxide doped chromic oxide (NiO: Cr2O3) nanoparticals were fabricated using thick-film screen printing of sol-gel grown powders. The structural, morphological investigations were carried out using XRD, AFM, and FESEM. Furthermore, the gas responsivity were evaluated towards the NH3 and NO2 gas. The NiO0.10: Cr2O3 nanoparticles exhibited excellent response of 95 % at 100oC and better selectivity towards NH3 with low response and recovery time as compared to pure Cr2O3 and can stand as reliable sensor element for NH3 sensor related applications.

View Publication Preview PDF
Crossref (2)
Crossref