In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature was measured by digital infrared thermometer, the gas flow rate were measured by gas flow meter, the pH, and the conductivity was measured by pH conductivity ultra-meter. The results illustrated that the conductivity and liquid temperature increase with increasing of exposure time. It can be conclude that the liquid properties were changed less than the boundaries that could affect adversely to the cells that located in the plasma jet.
With the spread of the use of liquefied petroleum gas (LPG) in developing countries for use in domestic cooking with the increase in the expansion and distribution of gas pipelines for residential buildings, the 2002 World Summit focused on sustainable development in clean energy for natural gas (NG) and LPG. The research aims to focus on the important aspects of design sustainability from an environmental point of view to reduce gas leakage, accidents, and explosions that occur socially to expand the distribution of LPG and motivate the consumers to use it instead of natural gas and other fuels, and from an economic point of view to take into account the annual cost and aesthetic imp
Autorías: Amwag Mohammed Ali Qasim, Ghassan Adeeb Abdulhasan. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 6, 2021. Artículo de Revista en Dialnet.
Abstract
The aim of the research is to identify the level of awareness and emotional experience among university students and to identify the effect of the educational program based on (Guttmann) model for developing awareness and emotional experience among university students by verifying the validity of the following zero hypotheses: 1) There are no statistically significant differences in the development of awareness and emotional experience among university students at the level of (0.05) between the mean scores of the experimental group in the pre and post-tests. 2) There are no statistically significant differences in the development of awareness and emotional experience among university students at the lev
... Show MoreObjective: preparing exercises for the third intensity zone for strength and speed for the legs, and identifying their effect on some physiological and biochemical indicators for (the level of lactic acid concentration, the concentration of sodium bicarbonate, the concentration level of (potassium K+) and (sodium Na+) in the blood, and the number of breathing times (RF) Research methodology: the experimental research method was adopted by designing the experimental and control groups on a sample of Army Sports Club players amounting to (16) players, deliberately selected (100%) from their community using a comprehensive enumeration method, and then divided into two groups of equal number, After determining the tests for physiologica
... Show MoreObjective: To identify the effect of the cube model on visual-spatial intelligence and learning the skill of spikinging in volleyball for female students, The researchers used the experimental method by designing two equivalent groups with pre- and post-measurements. Research methodology: The main research sample of (30) female students was selected from the research community represented by second-stage students in the College of Physical Education and Sports Sciences - University of Baghdad for the academic year (2024-2025). The sample was divided equally into two control and experimental groups. The researchers conducted the sample homogenization process and the equivalence process between the two groups in the variables of visua
... Show MorePseudomonas aeruginosa is a common and major opportunistic human pathogen, its causes many and dangersinfectious diseases due to death in some timesex: cystic fibrosis , wounds inflammation , burns inflammation , urinary tract infection , other many infections otitis external , Endocarditis , nosocomial infection and also causes other blood infections (Bacteremia). thereforebecomes founding fast and exact identification of P. aeruginosafrom samples culture very important.However, identification of this species may be problematic due to the marked phenotypic variabilitydemonstrated by samples isolates and the presence of other closely related species. To facilitate species identification, we used 16S ribosomal DNA(rRNA) sequence data
... Show MoreA number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The dur
... Show MoreHigh-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the
... Show More