Polymer electrolytes were prepared using the solution cast technology. Under some conditions, the electrolyte content of polymers was analyzed in constant percent of PVA/PVP (50:50), ethylene carbonate (EC), and propylene carbonate (PC) (1:1) with different proportions of potassium iodide (KI) (10, 20, 30, 40, 50 wt%) and iodine (I2) = 10 wt% of salt. Fourier Transmission Infrared (FTIR) studies confirmed the complex formation of polymer blends. Electrical conductivity was calculated with an impedance analyzer in the frequency range 50 Hz–1MHz and in the temperature range 293–343 K. The highest electrical conductivity value of 5.3 × 10-3 (S/cm) was observed for electrolytes with 50 wt% KI concentration at room temperature. The magnitude of electrical conductivity was increased with the increase in the salt concentration and temperature. The blend electrolytes have a high dielectric constant at lower frequencies which may be attributed to the dipoles providing sufficient time to get aligned with the electric field, resulting in higher polarization. The reduction of activation energy (Ea) suggests that faster-conducting electrolyte ions want less energy to move.
The adsorption of Ru and Ce were carried out using manganese dioxide as adsorbent. The Optimization of the adsorption conditions were studied as a function of shaking time, nitric acid, metal ions, concentrations and temperature effects. A rapid initial adsorption on MnO2 is followed by a steady and slow increase of metal uptake. The equilibration time is reached after four hours shaking for Ru and Ce and the adsorption is much better from one molar acidic solution and 90°C.
The efficient removal of dissolved organic compounds (DOC) from wastewater has become a major environmental concern because of its high toxicity even at low concentrations. Therefore, a technique was needed to reduce these pollutants. Ion exchange technology (IE) was used with AmberliteTM IR120 Na, AmberliteTM IR96RF, and AmberliteTM IR402, firstly by using anion and mixed bed system, where the following variables are investigated for the process of adsorption: The height of the bed in column (8,10 and 14 cm), different concentrations of (DOC) content at constant flow rate. The use of an ion exchanger unit (continuous system) with three columns (cation, anion, and mixed bed) was studied.
... Show MoreThree-dimensional seismic reflection study was conducted for the Eastern
Baghdad oil field which is located in the middle part of Iraq within Al-Madaaen
province that belong to Baghdad governarate, South of Diyala River , this field
includes two southern parts (S1 and S2), the study area was about 781.905 km 2 for
the upper Cretaceous age, synthetic seismogram was generated from data of EB-5
and EB-1 wells. Saadi reflector was picked and identified to determine the Hartha
Formation. The seismic sections and time slice maps confirmed that the upper
Cretaceous age was affected by faults and the indicators of faults ended within
Hartha Formation and continue to the deeper formations with increasing intensity.
The
Breast tumors patients generally have more oxidative stress than normal females. This was clear from a highly significant elevation (P<0.05) in malondialdehyde level in RBCs, serum and tissue of all patients groups with breast cancer as compared with control group. In this study we had found that free radicals in malignant breast tumors were higher than benign tumors, therefore the MDA might be used as a marker for prognosis of the disease.
Improving in assembling technology has provided machines of higher evaluation with better resistances and managed behavior. This machinery led to remarkably higher dynamic forces and therefore higher stresses. In this paper, a dynamic investigation of rectangular machine diesel and gas engines foundation at the top surface of one-layer dry sand with various states (i.e., loose, medium and dense) was carried out. The dynamic investigation is performed numerically by utilizing limited component programming, PLAXIS 3D. The soil is accepted as flexible totally plastic material submits to Mohr-Coulomb yield basis. A harmonic load is applied at the foundation with amplitude of 10 kPa at a frequency of (10, 15 and 20) HZ and se
... Show MoreThe study area is located at AL Jabal AL-Akhdar region North Eastern part of Libya. The study includes (23) fresh samples that are taken from Darnah limestone Formation, these samples were distributed on and covered about (210) km2. The porosities and permeabilities of these samples were determined. This study is important because this formation is considered as a good reservoir for hydrocarbon accumulation in other places in Libya.
The porosity was measured by three different methods namely by porosimeter (using core samples), thin sections and binocular microscope. The permeability are also measured by two methods, the first method was by Nitrogen method and the other is by Klinkenberg method. The instrument that used for measuring
Inflammatory bowel disease (IBD) a chronic inflammatory condition of the gastrointestinal tract characterized by alternating episodes of clinical relapse and remission (Wallace, 2014), with Crohn's disease (CD) and ulcerative colitis (UC) being the two primary subtypes (Souza, 2016). The present study was achieved in Baghdad teaching hospital from November 2021 to June 2022 to prove if the diagnostic marker of Crohn’s disease (CD) (IL-6, CRP and Calprotectin( are rises in saliva as in sera and if there are significant difference in the levels of those markers between the Crohn’s disease (CD)group and control group.
The recent study was measured the levels of C-reactive protein (CRP), Interleukin-6 (IL6
... Show MoreThin films of pure tin mono-sulfide SnS and tin mono-sulfide for (1,2,3,4)% fluorine SnS:F with Thicknesses of (0.85 ±0.05) ?m and (0.45±0.05) ?m respectively were prepared by chemical spray pyrolysis technique. the effect of doping of F on structural and optical properties has been studied. X-Ray diffraction analysis showed that the prepared films were polycrystalline with orthorhombic structure. It was found that doping increased the intensity of diffraction peaks. Optical properties of all samples were studied by recording the absorption and transmission spectrum in range of wave lengths (300-900) nm. The optical energy gap for direct forbidden transi
... Show MoreHeat pipes and two‐phase thermosyphon systems are passive heat transfer systems that employ a two‐phase cycle of a working fluid within a completely sealed system. Consequently, heat exchangers based on heat pipes have low thermal resistance and high effective thermal conductivity, which can reach up to the order of (105 W/(m K)). In energy recovery systems where the two streams should be unmixed, such as airconditioning systems of biological laboratories and operating rooms in hospitals, heat pipe heat exchangers (HPHEs) are recommended. In this study, an experimental and theoretical study was carried out on the thermal performance of an air‐to‐air HPHE filled with two refrigerants as working fluids, R22 and R407c. The heat pipe he
... Show More