Preferred Language
Articles
/
ijp-1093
FTIR and Electrical Behavior of Blend Electrolytes Based on (PVA/PVP)
...Show More Authors

Polymer electrolytes were prepared using the solution cast technology. Under some conditions, the electrolyte content of polymers was analyzed in constant percent of PVA/PVP (50:50), ethylene carbonate (EC), and propylene carbonate (PC) (1:1) with different proportions of potassium iodide (KI) (10, 20, 30, 40, 50 wt%) and iodine (I2) = 10 wt% of salt. Fourier Transmission Infrared (FTIR) studies confirmed the complex formation of polymer blends. Electrical conductivity was calculated with an impedance analyzer in the frequency range 50 Hz–1MHz and in the temperature range 293–343 K. The highest electrical conductivity value of 5.3 × 10-3 (S/cm) was observed for electrolytes with 50 wt% KI concentration at room temperature. The magnitude of electrical conductivity was increased with the increase in the salt concentration and temperature. The blend electrolytes have a high dielectric constant at lower frequencies which may be attributed to the dipoles providing sufficient time to get aligned with the electric field, resulting in higher polarization. The reduction of activation energy (Ea) suggests that faster-conducting electrolyte ions want less energy to move.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
PROTOTYPING TO DESIGN AN ANAGLYPH 3D IMAGE BASED ON WATERFALL MODEL
...Show More Authors

In this paper, a discussion of the principles of stereoscopy is presented, and the phases
of 3D image production of which is based on the Waterfall model. Also, the results are based
on one of the 3D technology which is Anaglyph and it's known to be of two colors (red and
cyan).
A 3D anaglyph image and visualization technologies will appear as a threedimensional
by using a classes (red/cyan) as considered part of other technologies used and
implemented for production of 3D videos (movies). And by using model to produce a
software to process anaglyph video, comes very important; for that, our proposed work is
implemented an anaglyph in Waterfall model to produced a 3D image which extracted from a
video.

View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering
National Grid Connected 3-Phase Inverter based on Photovoltaic Solar System
...Show More Authors

In this paper, a national grid-connected photovoltaic (PV) system is proposed. It extracts the maximum power point (MPP) using three-incremental-steps perturb and observe (TISP&O) maximum power point tracking (MPPT) method. It improves the classic P&O by using three incremental duty ratio (ΔD) instead of a single one in the conventional P and O MPPT method. Therefore, the system's performance is improved to a higher speed and less power fluctuation around the MPP. The Boost converter controls the MPPT and then is connected to a three-phase voltage source inverter (VSI). This type of inverter needs a high and constant input voltage. A second-order low pass (LC) filter is connected to the output of VSI to reduce t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Applying A* Path Planning Algorithm Based on Modified C-Space Analysis
...Show More Authors

In this paper, a modified derivation has been introduced to analyze the construction of C-space. The profit from using C-space is to make the process of path planning more safety and easer. After getting the C-space construction and map for two-link planar robot arm, which include all the possible situations of collision between robot parts and obstacle(s), the A* algorithm, which is usually used to find a heuristic path on Cartesian W-space, has been used to find a heuristic path on C-space map. Several modifications are needed to apply the methodology for a manipulator with degrees of freedom more than two. The results of C-space map, which are derived by the modified analysis, prove the accuracy of the overall C-space mapping and cons

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Jul 15 2019
Journal Name
Iet Microwaves, Antennas & Propagation
Hilbert metamaterial printed antenna based on organic substrates for energy harvesting
...Show More Authors

Abstract In this study, an investigation is conducted to realise the possibility of organic materials use in radio frequency (RF) electronics for RF-energy harvesting. Iraqi palm tree remnants mixed with nickel oxide nanoparticles hosted in polyethylene, INP substrates, is proposed for this study. Moreover, a metamaterial (MTM) antenna is printed on the created INP substrate of 0.8 mm thickness using silver nanoparticles conductive ink. The fabricated antenna performances are instigated numerically than validated experimentally in terms of S11 spectra and radiation patterns. It is found that the proposed antenna shows an ultra-wide band matching bandwidth to cover the frequencies from 2.4 to 10 GHz with bore-sight gain variation from 2.2 to

... Show More
View Publication
Scopus (49)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Advanced Computer Science And Applications
Achieving Flatness: Honeywords Generation Method for Passwords based on user behaviours
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Sat Oct 03 2009
Journal Name
Proceeding Of 3rd Scientific Conference Of The College Of Science
Research Address: New Multispectral Image Classification Methods Based on Scatterplot Technique
...Show More Authors

Publication Date
Fri Sep 30 2016
Journal Name
Australian Journal Of Basic And Applied Sciences
Programming Exam Questions Classification Based On Bloom’s Taxonomy Using Grammatical Rule
...Show More Authors

Preview PDF
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Improving Nursing process Performance based on service scheduling dimensions. ( Field research)
...Show More Authors

Abstract :

This present paper sheds the light on dimensions of scheduling the service that includes( the easiness of performing the service, willingness , health factors, psychological sides, family matters ,diminishing the time of waiting that improve  performance of nursing process including ( the willingness of performance, the ability to perform  the performance , opportunity of performance) . There is genuine problem in the Iraqi hospitals  lying into the weakness of nursing staffs , no central decision to define and organize schedules. Thus the researcher has chosen  this problem as to be his  title . The research come a to develop  the nursing service

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Commun.fac.sci.univ.ank.series A2-a3
ULTRAHIGH SENSITIVE REFRACTIVE INDEX SENSOR BASED ON TAPERED MULTICORE OPTICAL FIBER
...Show More Authors

The refractive index sensors based on tapered optical fiber are attractive for many industries due to sensing capability in a variety of application. In this paper, we proposed a refractive index sensor based on multicore fiber (MCF) sandwiched between two standard single mode fibers (SMF). The sensor consisting of three sections, SMF- MCF-SMF is structurally simple and can be easily produced by joining these parts. The MFC contains seven cores and these cores are surrounded by a single cladding. The sensing region is obtained by tapering the MCF section where the evanescent field is generated. The single mode propagating along the SMF is stimulated at the first joint and is coupled to the cladding modes. These modes interfere with the core

... Show More