Preferred Language
Articles
/
ijl-88
Sealing Depth of Q-Switched Nd:YAG 1064nm Laser in the Treatment of Patients with Hypersensitive Teeth: An In Vitro Study
...Show More Authors

The purpose of this work was to study the effects of the Nd:YAG laser on exposed dentinal
tubules of human extracted teeth using a scanning electron microscope (SEM). Eighty 2.5mm-thick
slices were cut at the cementoenamel junction from 20 extracted human teeth with an electric saw. A
diamond bur was used to remove the cementum layer to expose the dentinal tubules. Each slice was
sectioned into four equal quadrants and the specimens were randomly divided into four groups (A to D ).
Groups B to D were lased for 2 mins using an Nd:YAG laser at 6 pulses per second at energy outputs of
80 , 100 and 120 mJ. Group A served as control. Under SEM observation, nonlased specimens showed
numerous exposed dentinal tubules. SEM observation revealed that application of Nd:YAG laser at
energy output of 80 mJ may cause melting of dentin and partial closure of exposed dentinal tubules
without dentin surface cracking. But when the energy output raised to 100 and 120 mJ more sealing of
dentinal tubules occurs. Heat generation occurred in all lased groups but the amount of temperature
increase was within the permissible limits(less than 5.5⁰C). The measured sealing depths were from 3-
5μm for groups B-D and the width of the created groove was 30μm in all lased groups. In conclusion
lasing with nanosecond Nd:YAG with a wavelength of 1064nm at 120mJ with 6Hz for 2 minutes (group
D) shows the efficient laser parameters for complete sealing of exposed dentinal tubules without
temperature increase to the damaging level of the pulp tissue.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
An Investigation Study of Thinning Distribution in Single Point Incremental Forming Using FEM Analysis
...Show More Authors

Single Point Incremental Forming (SPIF) is a forming technique of sheet material based on layered manufacturing principles. The sheet part is locally deformed through horizontal slices. The moving locus of forming tool (called as toolpath) in these slices constructed to the finished part was performed by the CNC technology. The toolpath was created directly from CAD model of final product. The forming tool is a Ball-end forming tool, which was moved along the toolpath while the edges of sheet material were clamped rigidly on fixture.

This paper presented an investigation study of thinning distribution of a conical shapes carried out by incremental forming and the validation of finite element method to evaluate the limits of the p

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Artificial Saliva on The Surface Roughness of Different Esthetic Archwires (An in Vitro Study)
...Show More Authors

Background:The demand for esthetic orthodontic appliances is increasing so that the esthetic orthodontic archwires were introduced. This in vitro study was designed to evaluate the surface roughness offiber-reinforced polymer composite (FRPC) archwires compared to coated nickel-titanium (NiTi) archwires immersed in artificial saliva. Materials and Methods:Three types of esthetic orthodontic archwires were used: FRPC (Dentaurum), Teflon coated NiTi (Dentaurum) and epoxy coated NiTi (Orthotechnology). They were round (0.018 inch) in cross section and cut into pieces of 15 mm in length.Forty pieces from each type were divided into four groups; one group was left at a dry condition and the other three groups were immersed in artificial saliva (

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees19gr
The use of cold atmospheric plasma in pentostam enhancement as Leishmaniasis treatment in vitro
...Show More Authors

This study illustrates in vitro effect of cold atmospheric plasma (CAP) on the treatment of Leishmania. In addition, the study evaluated the effect of drug treatment (pentostam) and the combination treatment of pentostan and CAP at different doses and incubation time 24 h in order to assess the most effective treatment. The duration of the cold plasma doses was 1 min, 2 min and 3 min, while the pentostam doses were 2.5 µg/ml and 5 µg/ml. The combinations therapies included combining the three cold plasma doses with the pentostam doses to test 6 combinations of treated in vitro. The maximum growth inhibition was given by combination treated 46% and 44% for donovani and tropica leishamnia respectively; these results give an indi

... Show More
View Publication
Scopus (13)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Physiological and Immunological Disturbance in Rheumatoid Arthritis Patients
...Show More Authors

            Rheumatoid arthritis (RA) is a systematic autoimmune disorder with chronic inflammation changes of unknown etiology. Various synovial inflammatory and proliferative alterations may contribute to the cartilaginous tissues and invasive bony tissues, leading to destructive joints and malformed bones. This disease is mostly due to infective microorganisms or genetic susceptibility causing immune system disturbances through triggering both T-cells and B-cells. Furthermore, different immune cells may secret cytokines, which are responsible for some RA pathogenesis activity. From ninety individuals, serum sample was collected; thirty of them were normal and sixty cases were patients with RA attended a privet medical clin

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Heliyon
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was tr

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Sep 04 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Factors Influencing Adalimumab Treatment Response in Patients with Rheumatoid Arthritis: The Future of Clinical Expertise
...Show More Authors

Rheumatoid arthritis (RA) is characterized by persistent joint inflammation, which is a defining feature of this chronic inflammatory condition. Considerable advancements have been made in the field of disease-modifying anti-rheumatic medicines (DMARDs), which effectively mitigate inflammation and forestall further joint deterioration. Anti-tumor necrosis factor-alpha (TNF-α) drugs, which are a class of biological DMARDs (bDMARDs), have been efficaciously employed in the treatment of RA in recent times Adalimumab, a TNF inhibitor, has demonstrated significant efficacy in reducing disease symptoms and halting disease progression in patients with RA. However, its use is associated with major side effects and high costs. In addition,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Dec 15 2011
Journal Name
Iraqi Journal Of Laser
Laser Hole Drilling of Stainless Steel 321H and Steel 33 Using 3D CO2 Laser CNC Machine
...Show More Authors

In present work an investigation for precise hole drilling via continuous wave (CW) CO2 laser at 150 W maximum output power and wavelength 10.6 μm was achieved with the assistance of computerized numerical controlled (CNC) machine and assist gases. The drilling process was done for thin sheets (0.1 – 0.3 mm) of two types of metals; stainless steel (sst) 321H, steel 33 (st). Changing light and process parameters such as laser power, exposure time and gas pressure was important for getting the optimum results. The obtained results were supported with computational results using the COMSOL 3.5a software code.

View Publication Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
The influence of He-Ne Laser (632.8 nm) on Candida albicans isolated from complete upper dentures: In vitro study
...Show More Authors

The main objective of this study is to determine whether the use of He-Ne Laser (632.8 nm wavelength and power 0.5 mW) is an eligible and effective tool to kill or reduce the cell viability of Candida albicans isolated from complete upper dentures. Twenty one swabs were taken from the complete upper dentures. Only six swabs showed positive cultures for C. albicans. The isolate was divided into two groups, group I was not irradiated (control), and group II was irradiated by He-Ne Laser for different periods (10, 15, 20, and 30) min. After irradiation, the results showed a significant reduction in the viable cell count and colonies diameters especially at exposure periods 10 and 15 min. Although the low power He-Ne Laser was not eradicating t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication
Crossref