The effect of 532nm Diode Pumped Solid State (DPSS) laser at power density of 5.234 W/cm2 on the growth of Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus was evaluated. These bacteria were isolated from samples taken from burn and infected wound areas of 55 patients admitted to the burn-wound unit in Al-Kindy teaching hospital in Baghdad during the period from October 2012 to March 2013. Each isolate was identified using microscopic, cultural and biochemical methods. A standard bacterial suspension was prepared for each isolate. Serial dilutions were then prepared and a dilution of 10-5 was selected. Irradiation experiments included four groups: (L-P-) bacterial suspension in saline solution, (L-P+) bacterial suspension in the presence of 0.1mg/ml photosensitizer (safranin O), (L+P-) bacterial suspension treated with laser radiation only and finally (L+P+) bacterial suspension treated with laser radiation in the presence of the photosensitizer. After irradiation, Cetrimide agar (P. aeruginosa) and Mannitol salt agar (S.aureus) were used. Seven replicates were used for each experimental group. Different times of exposure were applied for irradiated groups. The results revealed that twenty two isolates out of 70 samples were positive for P. aeruginosa (31%) and fifteen isolates out of 35 samples were positive for S. aureus (42%). The combined effect of DPSS laser and safranine O was significantly effective in reducing the number of Colony Forming Units per milliliter (CFU/ml) of P. aeruginosa and S. aureus compared with control groups. Almost a complete bacterial mortality achieved at 25 and 5 minutes of exposing to laser light in the presence of safranin O for P. aeruginosa and S. aureus respectively, suggesting that singlet oxygen (O2*) and/or reactive oxygen species (ROS) were involved in the killing of the bacteria.
We have investigated the impact of laser pulse wavelength on the quantity of ablated materials. Specifically, this study investigated the structural, optical, and morphological characteristics of tungsten trioxide (WO3) nanoparticles (NPs) that were synthesized using the technique of pulsed-laser ablation of a tungsten plate. A DD drop of water was used as the ablation environment at a fixed fluence at 76.43 J/cm2 and pulse number was 400 pulses of the laser. The first and second harmonic generation ablations were carried out, corresponding to wavelengths of 1064 and 532 nm, respectively. The Q-switched Nd: YAG laser operates at a repetition rate of 1 Hz and has a pulse width of roughly 15 ns. These parameters are applicable to both wavelen
... Show MoreThis research includes a study of dezincification by corrosion from brass alloys in three types of media, which are acidic solution, basic and slat solution in different percentages. The study show the higher dezincification occurs in basic solution which decrease the fatigue properties where the fatigue properties are inversely proportional with dezincification.
This research was to determine the effect of rare earth metal (REM) on the as-cast microstructure of Mg-4Al alloy. The rare earth metal used here is Lanthanum to produce Mg-4Al-1.5La alloy. The microstructure was characterized by optical microscopy. The phases of this alloy were identified by X-ray diffraction. The microstructure of Mg-4Al consists of α-Mg and grain boundaries with precipitated phase particles. With the addition of Lanthanum, three distinct phases were identified in the X-ray diffraction patterns of the as cast Mg-4Al-1.5La: Mg, Al11La3, Al4La. The Mg17Al12 phase was not detected. The addition of Lanthanium increases the hardness and dec
... Show MoreThe effect of laser radiation on human aorta, coronary, and pulmonary arteries, and pulmonary veins has been investigated. Xenon-Chloride (eximer), Nitrogen, and Nd-YAG pulsed lasers of wavelengths 308, 337, and 1060 nm respectively were used. Their effects on fresh postmortem tissues, normal and diseased, was studied. The diameter and depth of ablation of the exposed tissues, in air, were measured as a function of many factors related to the type of laser and nature of the tissue. The effect of properties of the applied lasers, such as average power density and deposited energy density, on the exposed tissue surface were studied. The increase of these two parameters cause an increase in the depth and diameter of ablation. However the di
... Show MoreIn this work, (CdO)1-x (CoO)x thin films were prepared on glass slides by laser-induced plasma using Nd:YAG laser with (λ=1064 nm) and duration (9 ns) at different laser energies (200-500 mJ) with ratio (x=0.5), The influence of laser energy on structural and optical properties has been studied. XRD patterns show the films have a structure of polycrystalline wurtzite. As for AFM tests results for the topography of the surface of the film, where the results showed that the grain size and the average roughness increase with increasing laser energy. The optical properties of all films were also studied and the results showed that the absorption coefficient for within the wavelength range (280-1100 nm), The value of the optical power gap fo
... Show MoreThis study aims to studying of Person and organization’s environment fit in a sample of Private bank’s reflection in its basic dimensions (Person-organization fit ,Person-Job fit, Person-group fit and Person- Person-fit )in the Work Outcomes (job satisfaction, the intention to leave the job, Job Engagement, and organizational citizenship behavior ).
The questionnair’e has been used as a basic instrument to gather data , As well as personal interviews with some of the staff of the research sample of private banks which were represented by (5) and included banks (Bank of Assyria for investment, the North Bank for Finance and Investment , Bank of the Tigris
... Show MoreTool wear is a major problem in machining operations because the resulting material loss gradually changes of the machine tool. There many factors may leads to material loss like; friction, corrosion, and also it’s happened by rubbing during machining processes between the work piece and the tool. Dimensional accuracy of the work piece, and also the surface finish will be reducing by tool wear. It can also increase cutting force. In this study, we focused on the effect of the coating process on crater wear problems. Crater wear is caused by the flow between the chip and the rake face of the tool, whereas flank wear is caused by the contact between the tool and the work piece. In reducing crater wear, aluminum titanium nitride (AlTiN) u
... Show MoreThe current research aims to identify the effect of the study hand-on strategy on the achievement of the chemistry subject at the first grade students in the government day schools. The Umm al-Mu 'mineen school was chosen by appointment the intentional, so that its student is the research sample of the second Rusafa Directorate for the academic year (2021-2022). Then, two divisions were randomly selected for the first average out of 6 divisions to represent the experimental group that is studying according to the strategy of the thinker hand and the other the control group that is studying according to the usual method. The equivalence of the two research groups was verified by a set of variables represented by (chronological age, previous
... Show MoreFootball has progressed from being a ritual and a celebration to become an amateur sport, a professional sport, and now, increasingly, a commercial sport. In the analysis of football business model, the systemic approach should be adopted. If sport is regarded as one of the business sectors, then the application of business system methodology can be fully justified. The interest to create strong football business system calls for the search of the ways of popularizing football business model and boosting the economic potential of its participants. In the research literature tend to ignore the business processes within the sports business. Besides, the systemic approach in football business is usually limited to p
... Show More