Preferred Language
Articles
/
ijl-43
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigmentation, one patient with gazzal eye, one patient with spilus nevus, one patient with becker's nevus. The time of treatment session was from 5-20 minutes according to the size of lesion at 3-4 week interval. The distributions of lesions were on different part of body, face, hand, forearm, and back. Twenty two patients completed the study; four patients defaulted from the study for unknown reasons. Conclusion: The use of Q-Switched lasers offers a low risk, effective therapy with minimal side effects because they offer bloodless, low risk, effective treatment, Q-Switched Nd:YAG lasers have replaced other methods and are now considered standard treatment. The Q-Switched Nd:YAG laser have great advantages in removing hyperpigmentation, its longer wavelength (1064nm) would increase dermal penetration and decrease melanin absorption so that it’s used in skin type (III,IV,V,VI) without the risk of depigmentation or hypopigmentation.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 07 2018
Journal Name
Indian Journal Of Natural Sciences
Evaluation of Drinking Water Quality in Al Wathba Treatment Plant in Baghdad City-Iraq
...Show More Authors

Publication Date
Tue May 28 2019
Journal Name
Al-khwarizmi Engineering Journal
Treatment of Waste Extract Lubricating Oil by Catalytic Cracking Process to Produce Light Fractions
...Show More Authors

The catalytic cracking of three feeds of extract lubricating oil, that produced as a by-product from the process of furfural extraction of lubricating oil base stock in AL-Dura refinery at different operating condition, were carried out at a fixed bed laboratory reactor. The initial boiling point for these feeds was 140 ºC for sample (1), 86 ºC for sample (2) and 80 ºC for sample (3). The catalytic cracking processes were carried out at temperature range 325-400 ºC and initially at atmospheric pressure after 30 minutes over 9.88 % HY-zeolite catalyst load. The comparison between the conversion at different operating conditions of catalytic cracking processes indicates that a high yield was obtained at 375°C, according to gasoline pr

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2024
Journal Name
Separation And Purification Technology
A comprehensive review on the use of Ti3C2Tx MXene in membrane-based water treatment
...Show More Authors

View Publication
Scopus (25)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
The International Tinnitus Journal
Is Topical Nasal Steroid Useful for Treatment of Otitis Media with Effusion in Children?
...Show More Authors

Background: Otitis media with effusion is a common and important pediatric clinical problem; it is the leading cause of hearing impairment in children. Medical treatment remains controversial. Aim: To evaluate the usefulness of using topical nasal steroids in the treatment of otitis media with effusion. Patients and Methods: Between November 2019 and October 2022, a prospective controlled clinical study was carried out in the department of otolaryngology at Al-Jerrahat Teaching Hospital in Medical City, Baghdad, Iraq. This study comprised 40 patients with bilateral otitis media with effusion (23 males, 17 females). Two groups were created for the patients. Patients in group A (20 patients) were treated with mometasone furoate nasal spra

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 24 2022
Journal Name
Healthcare
Incidence of Gingival Black Triangles following Treatment with Fixed Orthodontic Appliance: A Systematic Review
...Show More Authors

This systematic review aimed to investigate the relation between orthodontic treatment (OT) and the incidence of the gingival black triangle (GBT) after completing treatment with a fixed orthodontic appliance, as well as the associated risk factors and the level of alveolar bone. Electronic and hand searches were conducted in three electronic databases for relevant articles published up to March 2022. Retrieved articles went through a two-step screening procedure, and the risk of bias (RoB) was assessed by the Joanna Briggs Institute checklists. The incidence of GBT after OT was set as the primary outcome, while the secondary outcomes were the risk factors associated with GBT and alveolar bone loss following OT. Out of 421 papers, 5

... Show More
View Publication
Scopus (15)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Oncology And Radiotherapy
The role of Modulation Complexity Score (MCS) of the VMAT and IMRT techniques in the treatment planning of left non-small lung cancer
...Show More Authors

Background: Lung cancer is a common disease for patients over the age of 50 years, especially males due to smoking habits. This study aimed to compare the modulation complexity score (MCS) for the advanced treatment planning techniques which the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). Materials and Methods: Thirty patients who had non-small lung cancerous tumors on their left side participated in this study. The range ages were 68 to 98 years, the heights were between 151 and 182cm and they having weights from 46 to 79 kg. For Each patient will create two plans dial using two different techniques, which will be Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy

... Show More
Scopus (1)
Scopus
Publication Date
Tue Jan 01 2019
Journal Name
Desalination And Water Treatment
Effect of synthesis parameters on the formation 4A zeolite crystals: characterization analysis and heavy metals uptake performance study for water treatment
...Show More Authors

View Publication
Scopus (49)
Crossref (42)
Scopus Clarivate Crossref
Publication Date
Thu Apr 08 2021
Journal Name
International Journal Of Dental Hygiene
Oral health awareness, attitude towards dental treatment, fear of infection and economic impact during COVID‐19 pandemic in the Middle East
...Show More Authors
Abstract<sec><title>Objectives

To assess the impact of COVID‐19 on oral hygiene (OH) awareness, attitude towards dental treatment, fear of infection and economic impact in the Middle East.

Methods

This survey was performed by online distribution of questionnaires in three countries in the Middle East (Jordan, Iraq and Egypt). The questionnaire consisted of five sections: the first section was aimed at collecting demographic data and the rest sections used to assess OH awareness, attitude towards dental treatment, degree of fear and economic impact of COVID‐19. The answers were either multiple choice, closed‐end (Yes or N

... Show More
View Publication
Scopus (19)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Acta Facultatis Medicae Naissensis
Operative treatment of femoral neck fractures with cannulated screws with and without platelet rich plasma in young adults: A comparative study
...Show More Authors

Many studies have evaluated the effect of platelet rich plasma (PRP) in the treatment of non-union fractures but few studies have investigated their effect on the union of femoral neck fractures or their functional outcome in young adults. The aim of this study was to evaluate the union time and functional outcome in young adult patients with femoral neck fracture managed by three cannulated screws injected with PRP and those managed by fixation only. This prospective study included 24 patients diagnosed with femoral neck fractures within 24 hours of presentation. Twelve cases in group A were managed by closed reduction and three cannulated screws fixation injected with PRP; twelve patients in group B were managed only by closed reduction a

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref