Preferred Language
Articles
/
ijl-349
PDF Cavity Disinfection Using Er,Cr:YSGG Laser Induced Photoacoustic Streaming Technique: Rand kareem Jassim Hussein Ali Jawad*
...Show More Authors

Abstract:

Aim: The goal of this research was to study the influence of Er,Cr:YSGG laser at short pulse duration (60 µsec) on the number of streptococcus mutans bacteria in vitro.

Material and Methods:  twenty-eight extracted third molars free of caries, cracks, and other irregularities were used. For the testing of the materials, both the agar well technique and a tooth cavity model were employed. The agar wells of plates that had been inoculated with Streptococcus mutans previously were stuffed with the test materials, in order to conduct the tests. The zones of inhibition were assessed using millimeter measurements, after an incubation period of 48 hours .In order to accomplish the tooth cavity model test, cylindrical cavities were invented in the occlusal surface of the teeth, which was kept even. The teeth were stored for 72 hours at 37°C in a broth culture of Streptococcus mutans. Following this, the teeth were divided arbitrarily into four groups of seven teeth (each including 14 cavity preparations). The experimental cavities in the first group (A) were not treated and considered as a control. In group B, a cavity disinfectant based on chlorhexidine was applied to the experimental cavities for 60 seconds. In group C, an erbium, chromium doped yttrium scandium gallium garnet laser was used at a short pulse duration (60 µsec) (0.25 watts, 15 Hz, 1% air, 1% water). In the last group, a chlorhexidine cavity disinfectant was applied for 60 seconds, followed by a laser treatment for 30 seconds with the same parameters as those described previously. The teeth were stored in saline for a period of three days. Standard amounts of dentin chips were retrieved from the cavity walls. ANOVA test was used to analyze repeated measure mean between tested concentration and control. Data expressed as mean ±SE.  LSD tests was used to calculate the significant differences between tested mean.

Result: After the statistical test, the highly significant difference in the diameter of inhibition zone was observed in group D (26 mm) where both chlorhexidine and laser were used followed by group B (18.71 mm) where the chlorhexidine gluconate based cavity disinfectant used alone, the least significant difference observed in group C (10.26mm) where the laser used alone.

Conclusion: According to this in vitro study, a photon-induced photoacoustic streaming technique using an Er,Cr:YSGG pulse laser at short pulse duration effectively agitates a chlorhexidine-based cavity disinfectant, which leads to the inhibition of Sterptococcus Mutans.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recor

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Mechanical Properties of AISI 316L Stainless Steel Produced Via Selective Laser Melting
...Show More Authors

Abstract Additive manufacturing has been recently emerged as an adaptable production process that can fundamentally affect traditional manufacturing in the future. Due to its manufacturing strategy, selective laser melting (SLM) is suitable for complicated configurations. Investigating the potential effects of scanning speed and laser power on the porosity, corrosion resistance and hardness of AISI 316L stainless steel produced by SLM is the goal of this work. When compared to rolled stainless steel, the improvement is noticeable. To examine the microstructure of the samples, the optical microscopy (OM), scanning electron microscopy (SEM), and EDX have been utilized. Hardness and tensile strength were us

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
The Efficacy of Er:YAG Laser on Intrapulpal Temperature Rise of Class V Cavity Preparation
...Show More Authors

The objective of this study is to determine the efficacy of class V Er:YAG laser (2940 nm) cavity preparation and conventional bur cavity preparation regarding Intrapulpal temperature rise during cavity preparation in extracted human premolar teeth. Twenty non carious premolar teeth extracted for orthodontic purposes were used and class V cavity preparation was applied both buccal and lingual sides for each tooth .Samples were equally grouped into two major groups according to cavity depth (1mm and 2mm). Each major group was further subdivided into two subgroupsof ten teeth for each (twenty cavities for each subgroup). TwinlightEr:YAG laser (2940 nm) with 500mJ pulse energy, P.R.R of 10 Hz and 63.69 J/cm2 energy density was used. The ana

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Fiber Laser Effect on Bond Strength of Titanium implant abutment to Resin Cement
...Show More Authors

Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Using Ultraviolet Technique for Well Water Disinfection
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF
Publication Date
Sun May 03 2015
Journal Name
Lasers In Medical Science
Investigations of radicular dentin permeability and ultrastructural changes after irradiation with Er,Cr:YSGG laser and dual wavelength (2780 and 940 nm) laser
...Show More Authors

View Publication
Scopus (31)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Investigation of Superhydrophobic/Hydrophobic Materials Properties Using Electrospinning Technique
...Show More Authors

     The aim of this research is to study the surface alteration characteristics and surface morphology of the superhydrophobic/hydrophobic nanocomposite coatings prepared by an electrospinning method to coat various materials such as glass and metal. This is considered as a low cost method of fabrication for polymer solutions of Polystyrene (PS), Polymethylmethacrylate (PMMA) and Silicone Rubber (RTV). Si were prepared in various wt% of composition for each solutions. Contact angle measurement, surface tension, viscosity, roughness tests were calculated for all specimens. SEM showed the morphology of the surfaces after coated. PS and PMMA showed superhydrophobic properties for metal substrate, while Si showed hydroph

... Show More
View Publication Preview PDF
Scopus (22)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Photomedicine And Laser Surgery
Evaluation of Temperature Elevation During Root Canal Treatment with Dual Wavelength Laser: 2780 nm Er,Cr:YSGG and 940 nm Diode
...Show More Authors

Scopus (33)
Scopus