Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females with age mean of 49.5) blood samples are obtained for the pilot study of clot formation and for studying the thermal effects of laser on blood, then the selected dose is applied on the extracted dental sockets of diabetes patients. Results: A significant difference is observed in the temperature of blood before and after laser application; the mean temperature elevation is less thanthe critical temperature of periodontal destruction. Moreover, firm blood clot is formed over the extraction site; the follow up of patients shows good healing with relatively no complications. Conclusions: Diode laser assists in the coagulation of the dental socket after tooth extraction without thermal damage to the periodontium.
This study deals with thirty non-insulin dependent diabetes mellitus patients suffering from diabetic nephropathy in addition to twenty five healthy control.Some biochemical parameters were determined in the serum of all subjects enrolled in the study.These parameters are serum glucose,serum urea,serum creatinine,total serum protein and serum albumin.The aim of the present study was to estimate these parameters in diabetic nephropathy patients. The results of the present study revealed a significant increase in glucose,urea and creatinine in patients as compared to controls . Also a significant decrease was found in total serum protein, serum albumin and albumin to globulin ratio (A/G) in patients com
... Show MoreBackground: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones develop Objective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study. Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized a
... Show MoreBackground: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones developObjective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study.Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show MoreBackground : In order for a tooth to erupt, two obvious requirements are needed. First, there has to be alveolar bone resorption of the bone overlying the crown of the tooth such that an eruption pathway is formed. Second, resorption of bony crypt and apposition of new one, third, there has to be a biological process that will result in the tooth moving through this eruption pathway.The amniotic sac contains a considerable quantity of stem cells. These amniotic stem cells are multipotent and able to differentiate into various tissues, which may be useful for human application. Receptor activator of nuclear factor kappa B ligand (RANKL) is concentrated on bone biology, more specifically bone metabolism. RANKL plays a vital role in osteoclast
... Show MoreA huge potential from researchers was presented for enhancing the nonlinear optical response for materials that interacts by light. In this work, we study the nonlinear optical response for chemically prepared nano- fluid of silver nanoparticles in de-ionized water with TSC (Tri-sodium citrate) protecting agent. By the means of self-defocusing technique and under CW 473 nm blue laser, the reflected diffraction pattern were observed and recorded by CCD camera. The results demonstrate that, the Ag nano-fluid shows a good third order nonlinear response and the magnitude of the nonlinear refractive index was in the order of 10−7 cm2/W. We determine the maximum change of the nonlinear refractive index and the related phase shift for the mat
... Show Moreβ-thalassaemia consists of 3 chief forms: thalassaemia primary (other called "cooley's Anaemia" or "Mediterranean durability Anaemia"), thalassaemia intermedia or thalassaemia minor also frequent termed "β-thalassaemia carrier", "β-thalassaemia trait" however, "heterozygous β-thalassaemia". separately from the rare magisterial forms, problem along β-thalassaemia essential are homozygotes or made heterozygotes because B0 and B+ genes, problem including thalassaemia intermedia are typically homozygotes and compound heterozygotes then subjected with thalassaemia minor are broadly heterozygotes.
In this study, we t
... Show MoreThe present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two
... Show MoreThis work describes the weathering effects (UV-Irradiation, and Rain) on the thermal conductivity of PS, PMMA, PS/PMMA blend for packaging application. The samples were prepared by cast method at different ratios (10, 30, 50, 70, and 90 %wt). It was seen that the thermal conductivity of PMMA (0.145 W/m.K), and for PS(0.095 W/m.K), which increases by PS ratio increase up to 50% PS/PMMA blend then decreased that was attributed to increase in miscibility of the blend involved. By UV-weathering, it was seen that thermal conductivity for PMMA increased with UV-weathering up to (30hr) then decreased, that was attributed to rigidity and defect formation, respectively. For 30%PS/PMMA, there results showed unsystematic decrease in thermal conduct
... Show MoreThe triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.