Preferred Language
Articles
/
ijl-269
Permeability of Radicular Dentine after Using Different Irrigant Activation Techniques Including Photo Induce Photoacoustic Streaming Technique
...Show More Authors

Background: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs)  on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and instrumented using Protaper Gold Rotary NiTi file system to size 40 taper 0.06. Er,Cr:YSGG pulsed laser (waterlase iplus Biolase, CA, USA) 2780 nm was used at short pulse duration (60 μs, 5 Hz ,air and water off) delivered by MD/iplus Glass Tips (MZ6) 600 μm in diameter, length=6 mm, calibration factor= 1.00. Ultrasonic activator ENDO1 (Guilin Woodpecker Medical Instrument Co., Ltd.china) was used with Ultrasonic activator tip ED98 (25#, 2% taper, 18.5mm) (Guilin Woodpecker Medical Instrument Co., Ltd.china). The samples were arbitrarily divided into three groups (n=6) and used as follows: (A) conventional irrigation with 5 ml of 17 % EDTA, (B) passive ultrasonic irrigation with 5 ml of 17 % EDTA,  (C) Er,Cr:YSGG induced photoacoustic streaming  with 5 ml of 17 % EDTA. After final irrigation with normal saline and drying, the roots were painted with nail varnish externally, and 2% methylene blue dye injected into canal until the canal filled with dye. The tooth was splitted at the fourth millimeters from root apex with a diamond disc representing the apical third. Picture was taken by Professional Digital SLR camera (Nikon D7100, Nikon Corporation, Thailand) with 40X magnification. The dye penetration was measured by using analytical software (measure picture CAD-KAS Kessler Germany). ANOVA test was used to analyse repeated measure mean between tested concentration (5.25% NaOCL, 17% EDTA) and control. Data was expressed as mean±SD. LSD (Least Significant Difference) test was used to calculate the significant differences between tested mean. Results: The mean values of the percentage of dye penetration area in two experimental groups was higher than the control group, as the follow (20.79±1.15control, 34.5453±0.45 ultrasonic group, 85.9804±2.69 Er,Cr.YSGG+17%EDTA at 0.5 W). The Percentage of dye penetration in Er,Cr:YSGG laser induced photoacoustic streaming with 17% EDTA was significantly high (P value 0.001), followed by ultrasonic activated group, while control group result in less Percentage of dye penetration than both study groups.  Conclusion: In this study, we concluded that Er,Cr:YSGG  pulsed laser  (0.5 W,5 Hz , air and water off) at short pulse duration (60 μs) with 17% EDTA using PIPS technique for activation of irrigant in endodontic treatment give better result than ultrasonic activation  in smear layer removal

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 24 2014
Journal Name
International Journal Of Environmental Science And Technology
Removal of copper ions from contaminated groundwater using waste foundry sand as permeable reactive barrier
...Show More Authors

Scopus (17)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Nov 19 2019
Journal Name
Iranian Journal Of Science And Technology, Transactions A: Science
Systematic Study of the Nuclear Structure for Some Exotic Nuclei Using Skyrme–Hartree–Fock Method
...Show More Authors

The ground state charge, neutron, proton and matter densities, the associated nuclear radii and the binding energy per nucleon of 8B, 17Ne, 23Al and 27P halo nuclei have been investigated using the Skyrme–Hartree–Fock (SHF) model with the new SKxs25 parameters. According to the calculated results, it is found that the SHF model with these Skyrme parameters provides a good description on the nuclear structure of above proton-rich halo nuclei. The elastic charge form factors of 8B and 17Ne halo nuclei and those of their stable isotopes 10B and 20Ne are calculated using plane-wave Born approximation with the charge density distributions obtained by SHF model to investigate the effect of the extended charge distributions of proton-rich nucl

... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Ecological Engineering
Biosorption of Heavy Metals from Synthetic Wastewater by Using Macro Algae Collected from Iraqi Marshlands
...Show More Authors

View Publication
Scopus (18)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Investigating the elastic and plastic behavior of I-steel beams by using carbon fiber laminates
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
Preservation of Required Chlorine Concentration in Baghdad Water Supply Networks using On-Site Chlorine Injection
...Show More Authors

The chlorine concentration variation in Baghdad water networks was studied. The
chlorine data were collected from Mayoralty of Baghdad and Ministry of Environment
(MOE) for the networks for both sides of the city Karkh and Rasafa for (2008-2009). The
study of these data indicates that there are no systematic testing program .Classified GIS
maps showed that the areas far from the treatment plants have almost always low
chlorine concentration .This indicates that the problem of the low chlorine concentration
in the far areas is due to cracks of pipe along the conveyance path ,as expected. The area's
most frequently have low concentration are Al-sadir,Al-Kadhimya, and Al-Amiria . It
was found also that the chlorine c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Optimization of Surface Roughness for Al-alloy in Electro-chemical Machining (ECM) using Taguchi Method
...Show More Authors

Electro-chemical Machining is  significant  process to remove metal with using  anodic dissolution. Electro-chemical machining use to removed metal workpiece from (7025) aluminum alloy using Potassium chloride (KCl) solution .The tool used was made from copper. In this present the optimize processes input parameter use are( current, gap and electrolyte concentration) and surface roughness (Ra) as output .The experiments on electro-chemical machining with use current (30, 50, 70)A, gap (1.00, 1.25, 1.50) mm and electrolyte concentration (100, 200, 300) (g/L).  The method (ANOVA) was used to limited the large influence factors affected on surface roughness and found the current was the large influence f

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of The American Medical Directors Association
Comprehensive Literature Review of Factors Influencing Medication Safety in Nursing Homes: Using a Systems Model
...Show More Authors

View Publication
Scopus (51)
Crossref (57)
Scopus Clarivate Crossref
Publication Date
Sun Nov 05 2017
Journal Name
International Journal Of Science And Research
Production of Biodiesel from Waste Cooking Oil using Cao-Egg Shell Waste Derived Heterogeneous Catalyst
...Show More Authors

Biodiesel is an environmentally friendly fuel and a good substitution for the fossil fuel. However, the purity of this fuel is a major concern that challenges researchers. In this study, a calcium oxide based catalyst has been prepared from local waste eggshells by the calcination method and tested in production biodiesel. The eggshells were powdered and calcined at different temperatures (700, 750, 800, 850 and 900 °C) and periods of time (1, 2, 3, 4 and 5 hr.). The effect of calcination temperature and calcination time on the structure and activity of the solid catalyst were examined by X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Brunaure-Emmett-Teller (BET). The optimum catalyst performance was obtained at 900 °C

... Show More
Crossref (11)
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Removal of COD from Petroleum refinery Wastewater by Electro-Coagulation Process Using SS/Al electrodes
...Show More Authors
Abstract<p>In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm<sup>−2</sup>), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re</p> ... Show More
View Publication
Scopus (41)
Crossref (26)
Scopus Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Adsorption of Chromium (Vi) from Aqueous Solutions using Low Cost Adsorbent: Equilibrium and Regeneration Studies
...Show More Authors

The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The
analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, th

... Show More
View Publication Preview PDF
Crossref (7)
Crossref