Preferred Language
Articles
/
ijl-261
Fractional CO2 Laser for Treatment of Female Stress Urinary Incontinence

Background: Urinary incontinence (UI) is a common disorder that affects women of various ages and impacts all aspects of life. This condition negatively influences quality of life. Fractional CO2 laser (10600nm) is the recent method for treatment of stress urinary incontinence in women. Objectives: The purpose of the study was to evaluate the efficacy and safety of fractional CO2 laser (10600nm) in the treatment of female stress urinary incontinence. Materials & Methods: This study was done from July 2020 to February 2021conducted at the laser institute for postgraduate studies university of Baghdad, patients collected from a private clinic and the Department of Obstetrics and Gynecology of Al-Kadhimiya private hospital, Baghdad, Iraq. Twenty women clinically diagnosed with SUI preferring non-surgical treatment were recruited to the study, their mean ages 43.6 + 13.9 years. Response to treatment was assessed at baseline  and at one month follow up after the third session using  a pelvic Floor Questionnaire (PFQ-UI).The laser parameters used were CO2 laser wavelength 10600 nm, power 35 watt, duration 1.0 ms, distance 1.0 mm, scan mode normal, scan times 4 and scan Rows 4,Interval  0.5s. Results: Most of the twenty women included in the study 80 % reported satisfaction and 20% not satisfied with treatment after 3 sessions of CO2 laser four weeks apart. Conclusion: Fractional CO2 laser treatment is an easy to use, minimally invasive and effective option for treatment of SUI.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 04 2022
Journal Name
Journal Of Educational And Psychological Researches
Fear of Intimacy and its Relationship with Post-Traumatic Stress Disorder among Yazidis Women

The current research aims to identify the fear of intimacy and post-traumatic stress disorder among Yazidi women and the correlation between them. To achieve the objectives of the research, the researcher adopted the Descutner, 1991 & (Thelen) scale, which consisted of (35) items. The researcher also adopted the post-traumatic stress disorder scale for (Davidson, 1995) translated by (Abdul Aziz Thabet), which consists of (17) items. These two scales were administered to a sample of (200) individuals. Then, the researcher analyzes the data using the Statistical Package for Social Sciences (SPSS). The results showed that the research sample of Yazidi women has a fear of intimacy. The research sample of Yazidi women is characterized by

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Conditions by 810 nm Diode Laser

When laser light incident on biological tissue, it is either reflected from the
surface of the tissue (e.g. the skin) or scattered inside the tissue or absorbed .The laser light will be
absorbed by water, hemoglobin and melanin. Absorption is also highly dependent on wave-length of
laser radiation. The absorbed light is converted into kinetic energy leading to laser effect that when
appropriately applied can produce reaction ranging from incision, vaporization to coagulation. Aim of
the study: To evaluate the efficiency of diode Laser 810 ± 20nm in treatment of oral lesions. Methods:
6 patients (2 females and 4 males) with different oral lesions were treated in the hospital of specialized
surgeries by the use of dio

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Spider Veins Using 810 nm Diode Laser

Spider veins are a common aesthetic problem mainly in females , the conventional method of treatment is by microsclerotherapy (injections) but laser therapy has become increasingly efficacious and a convenient method for treatment. The present study was performed to investigate the effectiveness and safety of pulsed diode laser (810nm) by doing thermal photocoagulation. Ten patients with lower limbs spider veins were included in this prospective study. They were treated with a repetitive pulsed diode laser in non contact technique using the following laser parameters (wave length 810nm,power 1 W ,pulse duration 0.1 s., pulse interval 0.5 s, spot diameter 4mm ,power density 7.9 W/cm2). Laser therapy was performed on day zero and day fourt

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Study the effect by CO2 laser on some optical properties of (Cd) thin film doping by Ni

In this research study the effect of irradiation by (CW) CO2 laser on some optical properties of (Cds) doping by Ni thin films of (1)µm thickness has been prepared by heat evaporation method. (X-Ray) diffraction technique showed the prepared films before and after irradiation are ploy crystalline hexagonal structure, optical properties were include recording of absorbance spectra for prepared films in the range of (400-1000) nm wave lengths, the absorption coefficient and the energy gap were calculated before and after irradiation, finally the irradiation affected (CdS) thin films by changing its color from the Transparent yellow to dark rough yellow and decrease the value absorption coefficient also increase the value of energy gap.

Crossref
View Publication Preview PDF
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Preparation of thin films of SiCN from gas-phase reaction induced by TEA-CO2 laser and study of their optical properties

In this paper, silicon carbonitried thin films were prepared by the method of photolysis of the silane (SiH4) and ethylene (C2H4) gases, with and without ammonia gas (NH3), which is represented by the ratio between the (PNH3) and (PSiH4 + PC2H4 + PNH3), (which assign by the letter X), X has the values (0, 0.13, 0.33). This method carried out by using TEA-CO2 laser, on glass substrate at (375 oC), deposition rate (0.416-0.833) nm/pulse thin film thickness of (500-1000) nm. The optical properties of the films were studied by using Absorbance and Transmittance spectrums in wavelength range of (400-1100) nm, the results showed that the electronic transitions is indirect and the energy gap for the SiCN films increase with increasing of nitrog

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Australian Dental Journal
Scopus (1)
Scopus
Publication Date
Thu Jan 20 2022
Journal Name
Journal Of Clinical Medicine
Comparison of the Safety and Efficacy of Laser Versus Pneumatic Intracorporeal Lithotripsy for Treatment of Bladder Stones in Children

This study aimed to compare the safety and efficacy of laser lithotripsy and pneumatic lithotripsy, the two most commonly used transurethral lithotripsy methods for treating bladder stones in children in Iraq. Between January 2013 and December 2016, 64 children with bladder stones were included in this prospective randomized study, after ethical committee approval and written consent from the children’s parents or caregivers were obtained. Patients were assigned randomly by computer software to two groups treated with either pneumatic cystolithotripsy or laser lithotripsy. A 9 Fr. semirigid ureteroscope was used to pass the lithotripter through and fragment the stone. A catheter of 8–12 Fr. was then introduced and kept in place

... Show More
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
effect of doping with nitrogen on the optical constant of the sic films prepared by TEA-Co2 Laser

In this research prepare membranes pure silicon carbide (SiC) as well as gas Alloy (ammonia) and using a laser was leaked membrane of glass flooring. To Drasesh optical properties of membranes prepared depending on the technique (Swanepoel) and Adhrt results obtained in general increased permeability pure silicon membranes

View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
Optical Design of Laser Zoom Beam Expander at near & far Ranges for Tracked Atmospheric Target

In this research, beam expander, BEX, is explained and designed for illuminating the
remote flying target. The BEX is optically designed to be suited for Nd:YAG laser of given
specifications. The BEX is modified to be zoom one to meet the conditions of preventing the
receiving unit; i.e the photodetector, from getting saturated at near and far laser tracking.
Decollimation could be achieved by automatic motor, which controls zoom lens of the BEX
according to the required expansion ratio of beam expander

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Colloid And Interface Science
Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage

Hypothesis CO2 geological storage (CGS) involves different mechanisms which can store millions of tonnes of CO2 per year in depleted hydrocarbon reservoirs and deep saline aquifers. But their storage capacity is influenced by the presence of different carboxylic compounds in the reservoir. These molecules strongly affect the water wetness of the rock, which has a dramatic impact on storage capacities and containment security. However, precise understanding of how these carboxylic acids influence the rock’s CO2-wettability is lacking. Experiments We thus systematically analysed these relationships as a function of pressure, temperature, storage depth and organic acid concentrations. A particular focus was on identifying organic acid conce

... Show More
Scopus (101)
Crossref (99)
Scopus Clarivate Crossref