Preferred Language
Articles
/
ijl-159
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by laser light according to the scattering (attenuation) of the laser beam during passing through the emulsion. The same droplet which where examined by the laser beam, where tested also under microphotography system. The result showed that the laser detection technique gives drop diameter smaller than that obtained by photographing.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 27 2018
Journal Name
Iraqi Journal Of Laser
Investigation of Densified SiO2 Sol-Gel Thin Films Using Conventional and DPSS Laser Techniques
...Show More Authors

The prepared nanostructure SiO2 thin films were densified by two techniques (conventional and Diode Pumped Solid State Laser (DPSS) (532 nm). X-ray diffraction (XRD), Field Emission Scanning electron microscopy (FESEM), and Atomic Force Microscope (AFM) technique were used to analyze the samples. XRD results showed that the structure of SiO2 thin films was amorphous for both Oven and Laser densification. FESEM and AFM images revealed that the shape of nano silica is spherical and the particle size is in nano range. The small particle size of SiO2 thin film densified by DPSS Laser was (26 nm) , while the smallest particle size of SiO2 thin film densified by Oven was (111 nm).

View Publication Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Physics: Conference Series
Determination of the Fertility of Southern Iraqi Soil Using Laser - Induced Breakdown Spectroscopy System
...Show More Authors

In this work, seven soil samples were brought brought to study and analyses the element concentrations from different southern regions of Iraq using laser-induced breakdown spectroscopy (LIBS) technique. It has been documented as an atomic emission spectroscopy (AES) technique. Laser-induced plasma utilized to analyze elements in materials (gases, liquids, and solids). In order to analyze elements in materials (gases, liquids, and solid). The Nd: YAG laser excitation source at 1064 nm with pulse width 9 ns is used to generate power density of 5.5 x 1012 MW/mm2, with optical spectrum in the range 320-740 nm. From this investigation, the soil sample analysis of the southern cities of Iraqi, it is concluded that the rich soil element of P, Si,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Laser Detection and Tracking System Using an Array of Photodiodes with Fuzzy Logic controller
...Show More Authors

In this work laser detection and tracking system (LDTS) is designed and implemented using a fuzzy logic controller (FLC). A 5 mW He-Ne laser system and an array of nine PN photodiodes are used in the detection system. The FLC is simulated using MATLAB package and the result is stored in a lock up table to use it in the real time operation of the system. The results give a good system response in the target detection and tracking in the real time operation.

View Publication Preview PDF
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Design of a Kinematic Neural Controller for Mobile Robots based on Enhanced Hybrid Firefly-Artificial Bee Colony Algorithm
...Show More Authors

The paper present design of a control structure that enables integration of a Kinematic neural controller for trajectory tracking of a nonholonomic differential two wheeled mobile robot, then  proposes a Kinematic neural controller to direct a National Instrument mobile robot (NI Mobile Robot). The controller is to make the actual velocity of the wheeled mobile robot close the required velocity by guarantees that the trajectory tracking mean squire error converges at minimum tracking error. The proposed tracking control system consists of two layers; The first layer is a multi-layer perceptron neural network system that controls the mobile robot to track the required path , The second layer is an optimization layer ,which is impleme

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 12 2019
Journal Name
Journal Of Economics And Administrative Sciences
Compare between simex and Quassi-likelihood methods in estimation of regression function in the presence of measurement error
...Show More Authors

       In recent years, the attention of researchers has increased of semi-parametric regression models, because it is possible to integrate the parametric and non-parametric regression models in one and then form a regression model has the potential to deal with the cruse of dimensionality in non-parametric models that occurs through the increasing of explanatory variables. Involved in the analysis and then decreasing the accuracy of the estimation. As well as the privilege of this type of model with flexibility in the application field compared to the parametric models which comply with certain conditions such as knowledge of the distribution of errors or the parametric models may

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Analysis of X-ray diffraction lines profile of Tio2 nanoparticles to determine the energy per unit volume and stress by using Halder-Wagner method
...Show More Authors

In this study, the Halder-Wagner method was used for an analysisX-ray lines of Tio2 nanoparticles. Where the software was used to calculate the FWHM and integral breath (β) to calculate the area under the curve for each of the lines of diffraction. After that, the general equation of the halder- Wagner method is applied to calculate the volume (D), strain (ε), stress (σ), and energy per unit(u). Volume (β). Where the value of the crystal volume was equal to (0.16149870 nm) and the strain was equal to (1.044126), stress (181.678 N / m2), and energy per unit volume (94.8474 J m-3).The results obtained from these methods were then compared with those obtained from each of the new paradigm of the HalderWagner method, the Shearer developm

... Show More
View Publication
Scopus Crossref
Publication Date
Mon May 30 2022
Journal Name
Pakistan Journal Of Medical And Health Sciences
Nurses' Knowledge Toward Continuous Positive Airway Pressure Machine at Respiratory Isolation Unit
...Show More Authors

Background: For patients with coronavirus disease(COVID-19), continuous positive airway pressure (CPAP) has been considered as a useful treatment. The goal of CPAP therapy is to enhance oxygenation, relieve breathing muscle strain, and maybe avoid intubation. If applied in a medical ward with a multidisciplinary approach, CPAP has the potential to reduce the burden on intensive care units. Methods: Cross-sectional design was conducted in the ALSHEFAA center for crises in Baghdad. Questionnaire filled by 80 nurses who work in Respiratory Isolation Unit who had chosen by non-probability (purposive) selection collected the data. Then the researcher used an observational checklist to evaluate nurses’ practice. The data was analyzed us

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Economics And Administrative Sciences
The ethical dimension of administrative accountants And its impact on the improvement and growth of staff potential in the economic unit
...Show More Authors

تعد المحاسبة بشكل عام علماً لكنها ليست من العلوم الصرفة وإنما من العلوم الإجتماعية مما يتطلب للتعامل مع المواضيع المحاسبية الأخذ بنظر الاعتبار الأشخاص المعنيين بالموضوع سواء كانوا المعدين للمخرجات المحاسبية أي المحاسبين، أو الاطراف ذوي المصالح المعنيين والمستفيدين من هذه المخرجات أي المستخدمين، ويعد المحاسب جزءاً من العملية الاجرائية نفسها وبهذا يكون دوره مزدوجاً يجمع بين كونه القائم بالبحث والقي

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
The effect of Laser Shock Peening on Fatigue Life Using Pure Water and Hydrofluoric Acid As a Confining Layer of Al – Alloy 7075-T6
...Show More Authors

Laser shock peening (LSP) is deemed as a deep-rooted technology for stimulating compressive residual stresses below the surface of metallic elements. As a result, fatigue lifespan is improved, and the substance properties become further resistant to wear and corrosion. The LSP provides more unfailing surface treatment and a potential decrease in microstructural damage. Laser shock peening is a well-organized method measured up to the mechanical shoot peening. This kind of surface handling can be fulfilled via an intense laser pulse focused on a substantial surface in extremely shorter intervals. In this work, Hydrofluoric Acid (HF) and pure water as a coating layer were utilized as a new technique to improve the properti

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 12 2017
Journal Name
Iraqi Journal Of Laser
A Comparative Evaluation of Post-Operative Pain and Function after Gingival Depigmentation Using 940 Nm Diode Laser And Conventional Bur Method: 6 Months Study
...Show More Authors

The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in

... Show More
View Publication Preview PDF