Preferred Language
Articles
/
ijl-155
Low Power He:Ne Laser Radiation in Killing Photosensitized Helicobacter pylori in Vitro
...Show More Authors

Four photosensitizers were used to test inhibitory effect of Helicobacter pylori bacteria using
low power helium: neon red laser radiation. Biopsies were collected from 176 patients and H. pylori were
isolated, identified and bacterial suspension was prepared. Samples of this suspension were mixed with
various low concentrations of the test sensitizer. The mixture samples were exposed to different laser
radiation doses. The samples were then inoculated and the inhibition zones were studied and compared
with their analogues of control samples. The most effective sensitizer with optimum concentration and
irradiation dose was determined. Statistical analysis of results was performed. The sensitizers' toluidine
blue and the methylene blue with concentration of 100 mg/ml were able to produce the same effect of
complete killing when irradiation energy density 13 J/cm2. However, thionin and crystal violet sensitizers
when used with the same concentration and exposed to the same laser dose, showed minor inhibitory
effect. Irradiation of bacterial samples with absence of sensitizer or sensitized samples at the
concentrations employed with out laser radiation has no effect on H. pylori viability in all of the
experiments.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Viii. International Scientific Congress Of Pure, Applied And Technological Sciences (minar Congress)
DETERMINING AN APPROPRIATE INITIAL VALUE OF ECCENTRICITY FOR LOW EARTH SATELLITES USING EULER METHOD
...Show More Authors

The major goal of this research was to use the Euler method to determine the best starting value for eccentricity. Various heights were chosen for satellites that were affected by atmospheric drag. It was explained how to turn the position and velocity components into orbital elements. Also, Euler integration method was explained. The results indicated that the drag is deviated the satellite trajectory from a keplerian orbit. As a result, the Keplerian orbital elements alter throughout time. Additionally, the current analysis showed that Euler method could only be used for low Earth orbits between (100 and 500) km and very small eccentricity (e = 0.001).

View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Internet Protocol Technology
A low cost paging scheme for clustered PMIPv6 protocol by head-MAG entity utilisation
...Show More Authors

View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Environmental Technology & Innovation
Environmental remediation of synthetic leachate produced from sanitary landfills using low-cost composite sorbent
...Show More Authors

Scopus (36)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Sun Feb 17 2019
Journal Name
Iraqi Journal Of Physics
A study of the solvent effect on the low temperature spectra of benzoanthracene molecules
...Show More Authors

been taken at room temperature down to liquid nitrogen temperature (77K). Polar and nonpolar solvents have been used to study the solvent effect on the absorption and fluorescence spectra of solute molecules. Some of the spectroscopic parameters have been determined as functions of solvent polarity and temperature. The results indicate that the band width FWHM increases with increasing the solvent polarity and temperature, while the peak emission cross section decreases with increasing of solvent polarity and decreases with increasing the temperatures. Clear vibrational structure spectra of benzoanthracene molecules have been observed in Nonane and Hexane solvents at 77K.

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 25 2021
Journal Name
Caai Transactions On Intelligence Technology
Shoulder girdle recognition using electrophysiological and low frequency anatomical contraction signals for prosthesis control
...Show More Authors

View Publication Preview PDF
Scopus (14)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
A Hybrid Coefficient Decimation- Interpolation Based Reconfigurable Low Complexity Filter Bank for Cognitive Radio
...Show More Authors

Non uniform channelization is a crucial task in cognitive radio receivers for obtaining separate channels from the digitized wideband input signal at different intervals of time. The two main requirements in the channelizer are reconfigurability and low complexity. In this paper, a reconfigurable architecture based on a combination of Improved Coefficient Decimation Method (ICDM) and Coefficient Interpolation Method (CIM) is proposed. The proposed Hybrid Coefficient Decimation-Interpolation Method (HCDIM) based filter bank (FB) is able to realize the same number of channels realized using (ICDM) but with a maximum decimation factor divided by the interpolation factor (L), which leads to less deterioration in stop band at

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Constructional Steel Research
Demountable steel-concrete composite beam with full-interaction and low degree of shear connection
...Show More Authors

It is suitable to use precast steel-concrete composite beams to quickly assemble a bridge or a building, particularly in isolated regions where cast-in-situ concrete is not a practical option. If steel-concrete composite beams are designed to allow demountability, they can also be extremely useful in the aftermath of natural disasters, such as earthquakes or flooding, to replace damaged infrastructure. Furthermore, rapid replacement of slabs is extremely beneficial in case of severe deterioration due to long-term stressors such as fatigue or corrosion. The only way to rapidly assemble and disassemble a steel-concrete composite structure is to use demountable shear connectors to connect/disconnect the steel beams to/from the concrete slab. I

... Show More
View Publication
Scopus (43)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Mon Oct 03 2022
Journal Name
Physica Scripta
Radiation shielding properties of Cd-Bi-Pb-Zn-borate glasses: influence of Bi<sub>2</sub>O<sub>3</sub> activation
...Show More Authors
Abstract<p>We report the detail characterizations and <italic>γ</italic>-radiation protecting characteristics of some new types of cadmium (Cd)-bismuth (Bi)-lead (Pb)-zinc (Zn)-borate glasses of the form (70-x)B<sub>2</sub>O<sub>3</sub>-10ZnO-10PbO-10CdO-xBi<sub>2</sub>O<sub>3</sub> (with x = 0 to 20 mol%) synthesized via melt-quenching process. The influence of various Bi<sub>2</sub>O<sub>3</sub> contents on the <italic>γ</italic>-radiation shielding traits of the obtained glass samples was evaluated by exposing them at different <italic>γ</italic>-ray energies (0.356, 0.662, 1.173, and 1.33 MeV) whic</p> ... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref