Preferred Language
Articles
/
ijl-132
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Low-Rate High-Quality Parametric Audio Coder based on Sinusoidal plus Noise Representations
...Show More Authors

This paper presents a parametric audio compression scheme intended for scalable audio coding applications, and is particularly well suited for operation at low rates, in the vicinity of 5 to 32 Kbps. The model consists of two complementary components: Sines plus Noise (SN). The principal component of the system is an. overlap-add analysis-by-synthesis sinusoidal model based on conjugate matching pursuits. Perceptual information about human hearing is explicitly included into the model by psychoacoustically weighting the pursuit metric. Once analyzed, SN parameters are efficiently quantized and coded. Our informal listening tests demonstrated that our coder gave competitive performance to the-state-of-the- art HelixTM Producer Plus 9 from

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 29 2023
Journal Name
Pakistan Journal Of Ophthalmology
Corneal Parameters Measurement in Healthy Subjects Using Scheimpflug and Anterior Segment Optical Coherence Tomography
...Show More Authors

Purpose:  To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design:  Descriptive observational. Place and Duration of Study:  Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods:  A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results:  Mean age was 28.54 ± 6.6 years, me

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 31 2023
Journal Name
College Of Islamic Sciences
The status of prophecy in the Islamic faith in light of the glorious Kharida system
...Show More Authors

Knowing the Messengers, peace and blessings be upon them, and explaining their obligatory, impossible, and permissible qualities is a legal necessity. It is a rooting of the faith, a means of understanding the Sharia, and a preventer from falling into the scourge of denial and bad manners against them. Therefore, sound belief in their presence is a major reason for the validity of the faith in the aspect of divinity and unseen hearing. Studying the status of prophethood is an urgent necessity in a time in which knowledge is scarce and attachment to the Messenger, may God Almighty’s prayers and peace be upon him, his family, and his companions, is weak, and suspicions and ideas hostile to the faith abound until we begin to hear - unfort

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Effect of Silver Nanoparticles on Fluorescence Intensity of Fluoreseina Dye Mixed in One Solution
...Show More Authors

Metal enhanced fluorescence (MEF) is an unequaled phenomenon of metal nanoparticle surface plasmons, when light interacts with the metal nanostructures (silver nanoparticles) which result electromagnetic fields to promote the sensitivity of fluorescence. This work endeavor to study the influence of silver nanoparticles on fluorescence intensity of Fluoreseina dye by employment mixture solution with different mixing ratio. Silver nanoparticles had been manufactured by the chemical reduction method so that Ag NP layer coating had been done by hot rotation liquid method. The optical properties of the prepared samples (mixture solution of Fluoreseina dye solutions and colloidal solution with 5 minutes prepared of Ag NPs) tested by using UV-V

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Sumer 3
Treatment of shallow and deep white spot lesions with three different mouthwashes evaluated by laser fluorescence (an in vitro study)
...Show More Authors

This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Electronically Implementation and Detection of Pulse Laser from Continuous Laser Diode
...Show More Authors

This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Laser Micro- And Nano-scale Processing
Physical principles of laser–material interaction regimes for laser machining processes
...Show More Authors

Lasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Heliyon
The influence of pulse duration and exposure time of Er,Cr:YSGG laser on lithium disilicate laminate debonding, an in vitro study
...Show More Authors

View Publication
Scopus (9)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Manufacturing Zener diode using ZnO-CuO-ZnO/Si structures deposited laser induced plasma technique
...Show More Authors

        In this paper Zener diode was manufactured using ZnO-CuO-ZnO/Si heterojunction structure that used laser induced plasma technique to prepare the nanofilms. Six samples were prepared with a different number of laser pulses, started with 200 to 600 pulses on ZnO tablet with fixed the number of laser pulses on CuO tablet at 300 pulses. The pulse energy of laser deposited was 900mJ using ZnO tablet and 600mJ using CuO tablet. All prepared films shown good behavior as Zener diode when using porous silicon as substrate.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 24 2024
Journal Name
Journal Of Optics
Performance analysis of optical communication networks utilizing optical fibers and OFDM technology
...Show More Authors

This document provides an examination of research, on combining orthogonal frequency division multiplexing (OFDM) and optical fibers in communication networks. With the increasing need for data speeds and efficient use of bandwidth experts have been exploring the connection between OFDM, valued for its ability to handle multipath interference and optimize spectral usage and optical fiber technology which provides superior data transmission capabilities with low signal loss and strong protection, against electromagnetic disturbances. The review summarizes discoveries from studies examining the pros and cons of using OFDM, in optical communication networks. It discusses obstacles like fiber nonlinearity, chromatic dispersion and the effects o

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref