Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no bleeding postoperatively. There was mild edema appear in first 2 days after the surgery, and then it
subsided gradually. There was no infection in all the patients treated. One day following the operation
the intra oral examination showed dark-brown necrotic tissue, friable with red inflamed line around the
edges. After five days, the observation revealed that the sloughs tissue was completely changed to white
color and was easily removed by gauze. Wound healing was excellent after only one week. All the
samples were diagnosed histopathologically as pyogenic granuloma.
Background: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to J
In the present work, the feasibility of formation near-ideal ohmic behavior of In/n-Si contact efficiently by 300 s duration Nd:YAG pulsed laser processing has been recognized. Several laser pulses energy densities have been used, and the optimal energy density that gives best results is obtained. Topography of the irradiated region was extensively discussed and supported with micrographic illustrations to determine the surface condition that can play the important role in the ohmic contact quality. I-V characteristics in the forward and reverse bias and barrier height measurements have been studied for different irradiated samples to determine the laser energy density that gives best ohmic behavior. Comparing the current results with
... Show MorePlasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri
... Show MoreThe aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x
This study investigates the results of electrocoagulation (EC) using aluminum (Al) electrodes as anode and stainless steel (grade 316) as a cathode for removing silica, calcium, and magnesium ions from simulated cooling tower blowdown waters. The simulated water contains (50 mg/l silica, 508 mg/l calcium, and 292 mg/l magnesium). The influence of different experimental parameters, such as current density (0.5, 1, and 2 mA/cm2), initial pH(5,7, and 10), the temperature of the simulated solution(250C and 35 0C), and electrolysis time was studied. The highest removal efficiency of 80.183%, 99.21%, and 98.06% for calcium, silica, and magnesium ions, respectively, were obtained at a current de
... Show MoreBackground: Clubfoot, or talipes equinovarus, is a congenital deformity that consist of; supination and adduction of the forefoot and midfoot; equinus of hindfoot and varus. It was found that more than 100,000 babies are born each year with congenital clubfoot
Objectives: The purpose of this study was to investigate the complications of ponseti method for treatment of children with idiopathic club foot.
Subjects and Methods: 50 children with 74 clubfeet were managed by Ponseti method from May 2019 to July 2020 in Al-Wasity teaching hospital with primary correction of the deformity followed sometimes by elongation of Achilles tendon then the pati
... Show MorePermanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carb
... Show MoreAlopecia (Baldness) is very usual trouble in current time. It is accompanied by an intensive weakening of the scalp's hair and follows a specific pattern. Hereditary predisposition plays a very important role in alopecia despite not completely understood. Alopecia can be typed to various categories according to etiology, may be due to hereditary factors, autoimmune disease, and drugs or chemicals. There are many options of strategies of treatment according to the type and causes of alopecia. Chemical or synthetic medications apply for the management of hair loss are accompanied by a wide range of undesirable effects. Naturally occurring drugs also play important role in alopecia management with minimal side effects.
لابد لكل باحث في أي موضوع يرغب في عن القارة الافريقية والمناطق المسلمة منها بشكل خاص ان يتلمس طرق حريتها وتحريرها وانعتاقها علية التحري والبحث عن العقدة الدينية التي عتنقها اهلها والتي جعلت منهم تواقين الى الحرية واثر هذة العقدة على ذلك الانسان في التحرير من كل اشكال العبودية
Followers and their followers (may Allah be pleased with them all) followed the approach of the guidance and the Sunnah of the Messenger of Allah Muhammad (peace be upon him) in the collection and codification of the hadith of the Prophet Muhammad in various Arab and Islamic areas. Subsequent judge Faqih Abu Bakr al-Ansari had a distinct effect during that time immortalized in the pages of our Islamic history in preserving the Sunnah of our great Prophet Muhammad (PBUH) and documenting the constants of Sharia and Islamic jurisprudence and its importance in the activity of intellectual and scientific movement in the Arab Islamic State.