Preferred Language
Articles
/
ijl-124
Immuno-hematological and biochemical changes in diabetic retinopathy patient`s blood after treatment by Nd-YAG laser
...Show More Authors

Diabetic retinopathy is one of most important complications of diabetes mellitus that can be treated by Nd:YAG laser. Laser is used in ophthalmic practice for photocoagulation and photodisruption. The purpose of this study is to evaluate changes in immunological ,hematological and biochemical values after treatment of diabetic retinopathy by laser. Blood samples from 10 patients suffering from diabetic retinopathy were taken before and after laser treatment to coagulate retina to prevent leakage and hemorraghe to avoid deterioration of vision.In group one (4 patients = 40%), blood tests were done one day after treatment. In group two (6 patients =60%) tests were done 7 days after treatment with laser. The study showed no clear changes in the values of biochemical tests(except glucouse is already high) and hemtologyical tests (except PT, PTT, clotting time and bleeding time for those patients taking l00mg acetylsalicylic acid or warfarin) after irradiation with laser, probably because that main organs that affecting these tests or the elements that involve in these tests have not been irradiated directly. The main changes were in mmunoglobulin values which increased as noticed in both groups, because all light- induced biological effects depend on the parameters of irradiation, the results suggest that the laser irradiation may play two principal roles in immunological changes. First, is stimulation of cellular proliferation, and stimulation of cellular differentiation that is responsible for different types of immunoglobulin.The other suggestion is that laser is acting as a triggering factor which induces systematic effects through the circulation when laser interacts with living cells so it has systemic effects through circulating blood.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Design of L-Band Multiwavelength Laser for TDM/WDM PON Application
...Show More Authors

This paper presents on the design of L-Band Multiwavelength laser for Hybrid Time Division Multiplexing/ Wavelength Division Multiplexing (TDM/WDM) Passive Optical Network (PON) application. In this design, an L-band Mulltiwavelength Laser is designed as the downstream signals for TDM/WDM PON. The downstream signals ranging from 1569.865 nm to 1581.973 nm with 100GHz spacing. The multiwavelength laser is designed using OptiSystem software and it is integrated into a TDM/WDM PON that is also designed using OptiSystem simulation software. By adapting multiwavelength fiber laser into a TDM/WDM network, a simple and low-cost downstream signal is proposed. From the simulation design, it is found that the proposed design is suitable to be used

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jun 10 2010
Journal Name
Iraqi Journal Of Laser
Improvement of Nonlinear Optical Properties for Mixture Laser Dyes Doped PMMA
...Show More Authors

The spectral characteristics and the nonlinear optical properties of the mixed donor (C-480) acceptor (Rh-6G) have been determined. The spectral characteristics are studied by recording their absorption and fluorescence spectra. The nonlinear optical properties were measured by z-scan technique, using Q-switched Nd: YAG laser with 1064 nm wavelength. The results showed that the optimum concentration of acceptor is responsible for increasing the absorption and the emission bandwidth of donor to full range and to 242 nm respectively by the energy transfer process, also the efficiency of the process was increased by increasing the donor and acceptor concentration. The obtained nonlinear properties results of the mixture C-480/ Rh-6G showed

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Preparation ultra fine particles from Ceramic refractory material using CO2 Laser
...Show More Authors

S a mples of compact magnesia and alumina were evaporated
using CO2-laser .The
Processed powders were characterized by electron microscopy
and both scanning and transmission electron microscope. The results
indicated that the particle size for both powders have reduced largely
to 0.003 nm and 0.07 nm for MgO and Al2O3, with increasing in
shape sphericity.

View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Optics & Laser Technology
Finite element thermal analysis for PMMA/st.st.304 laser direct joining
...Show More Authors

This work is concerned with building a three-dimensional (3D) ab-initio models that is capable of predicting the thermal distribution of laser direct joining processes between Polymethylmethacrylate (PMMA) and stainless steel 304(st.st.304). ANSYS® simulation based on finite element analysis (FEA) was implemented for materials joining in two modes; laser transmission joining (LTJ) and conduction joining (CJ). ANSYS® simulator was used to explore the thermal environment of the joints during joining (heating time) and after joining (cooling time). For both modes, the investigation is carried out when the laser spot is at the middle of the joint width, at 15 mm from the commencement point (joint edge) at traveling time of 3.75 s. Process par

... Show More
View Publication
Scopus (46)
Crossref (43)
Scopus Clarivate Crossref
Publication Date
Wed Aug 06 2025
Journal Name
Journal Of Physical Education
Standard Criteria for Some Special Abilities as Indicator for Selecting Iraqi Club's Weightlifters Aged 14 – 16 years Old
...Show More Authors

View Publication
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Effect of Polyherbs-Mixture Composed of Nigella sativa, Trigonella foenum - graceum, Cyperus rotundus and Teucrium polium on the Levels of Malondialdehyde and Glutathione for Diabetic Patients Type II
...Show More Authors

This study included estimation of glutathione (GSH) and Malondialdehyde (MDA) levels in the serum of diabetic patients type II who are treated with a polyherbs mixture (Nigella sativa, Trigonella foenum-graeum, Cyperus rotundus and Teucrium polium) for three months of treatments. Seventy samples of diabetic patients Type II male and females with age about (35-60) years were taken including 44 samples for group one (24 male, 20 female) who used herbs accompanied with chemical treatment (drugs) and 26 samples for the second group (13male and 13 female) who used herbs only. These groups were compared with 60 samples obtained from healthy persons (29 male, 31 female) at the same age of patients as a control group. Effect of age and treatment fo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Preparation, characterization and study of biological activity and laser effect on the new Cu(II) complexes containing mixed benziloxime and furfuraldehydeazine ligands
...Show More Authors

Abstract: New copper(II) complexes with mixed ligand benziloxime (BOxH) and furfural-dehydeazine (FA) using classical (with and without solvent) and microwave heating methods have been prepared. The resulting complexes have been characterized using physico-chemical techniques. The study suggested that the ligands formed neutral complexes had general formulas [Cu(FA)(BOXH)(Ac)2] and [Cu(FA)(BOX)(OH)] in neutral (or acidic) and basic medium, respectively. Accordingly, hexa-coordinated mono-nuclear complexes have been investigated by this study and having distorted octahedral geometry. The effect of laser have been studied on solid ligands and solid complexes, no effect have been observed on most compounds through the results of melting poin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 19 2017
Journal Name
Iraqi Journal Of Laser
Effects of Diode Laser 940 nm with and without 5 % Sodium Fluoride White Varnish with Tri-calcium Phosphate on Dentin Permeability (In vitro study)
...Show More Authors

It is found that hypersensitive teeth have a larger number and wider patent tubules than those of non-sensitive teeth. Objective: The aim of this study is to compare between the effects of diode laser at different power densities, with and without sodium fluoride on the sealing of exposed dentinal tubules and dentin permeability. Materials and methods: 118 teeth were used. Samples were divided into three major groups. The first consisted of 100 teeth used for permeability test. The second consisted of 16 teeth for measuring external surface temperature elevation while irradiation. The third, in turn, consisted of one pair of teeth observed under SEM for dentine surface morphology analysis. Results: For dentin permeability measurement, th

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 27 2018
Journal Name
Pharmaceutics
Ocular Drug Delivery Barriers—Role of Nanocarriers in the Treatment of Anterior Segment Ocular Diseases
...Show More Authors

Ocular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barr

... Show More
View Publication
Scopus (328)
Crossref (317)
Scopus Clarivate Crossref