Diabetic retinopathy is one of most important complications of diabetes mellitus that can be treated by Nd:YAG laser. Laser is used in ophthalmic practice for photocoagulation and photodisruption. The purpose of this study is to evaluate changes in immunological ,hematological and biochemical values after treatment of diabetic retinopathy by laser. Blood samples from 10 patients suffering from diabetic retinopathy were taken before and after laser treatment to coagulate retina to prevent leakage and hemorraghe to avoid deterioration of vision.In group one (4 patients = 40%), blood tests were done one day after treatment. In group two (6 patients =60%) tests were done 7 days after treatment with laser. The study showed no clear changes in the values of biochemical tests(except glucouse is already high) and hemtologyical tests (except PT, PTT, clotting time and bleeding time for those patients taking l00mg acetylsalicylic acid or warfarin) after irradiation with laser, probably because that main organs that affecting these tests or the elements that involve in these tests have not been irradiated directly. The main changes were in mmunoglobulin values which increased as noticed in both groups, because all light- induced biological effects depend on the parameters of irradiation, the results suggest that the laser irradiation may play two principal roles in immunological changes. First, is stimulation of cellular proliferation, and stimulation of cellular differentiation that is responsible for different types of immunoglobulin.The other suggestion is that laser is acting as a triggering factor which induces systematic effects through the circulation when laser interacts with living cells so it has systemic effects through circulating blood.
Background: Hyperthyroidism occurs due to over production of thyroid hormones, one types of hyperthyroidism was Graves, disease. Hyperthyroidism is characterized by high level of serum thyroxin, triiodothyronine and low level of thyroid stimulated hormones. Material and Methods: fifty two hyperthyroid patients, thirty patients under treatment with carbimazole and other twenty two patients under treatment with radioactive iodine, and sixty healthy control group. The average salivary flow rate was calculated as ml/5mint.The concentration of calcium, potassium, and total protein were determined in the salivary supernatant sample. This is done through different biochemical tests. Determination of salivary IgA is done by ELIZA. Results: The most
... Show MoreDiabetes mellitus is a set of metabolic diseases, the most prevalent of which is chronic hyperglycemia. The culprits include insulin synthesis, insulin action, or both. Osteoporosis is a progressive systemic skeletal disorder defined by decreased bone mass and micro architectural degeneration of bone tissue, resulting in increased bone fragility and fracture risk, according to the World Health Organization (WHO). The degree of Nervosa damage determines how much a diabetic patient's body has been compromised. The current study's goal is an estimation: Age, BMI, FBS, HbA1C, D3, ALP, Ca, P, and Osteocalcin in Iraqi T2DM Women's patients with and without Osteoporosis. Three vitamins are required for Osteocalcin biosynthesis: vitamin K for Gla f
... Show MoreChronic kidney disease (CKD) is described as an abnormalities of renal function, existing for a long period of time. By reason of the early grades of Chronic kidney disease can be experiences no symptoms, its premature identification is strenuous. initial stage CRD can cause various complications, such as anemia, matabolyic disorders of bone mineral. The study was done to assess the effect the chronic renal disease stage on the Osteoprotegerin, 1,25 dihydroxyvitamin D, Obestatin levels and some biochemical parameters in patients not undertaken dialysis therapy. In this case-control study fifty-five patients with Kidney failure and fourty healthy people were examined. Circulating concentrations of Osteoprotegerin, 1,25 dihydroxyvitamin D
... Show MoreThis research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic
Abstract
The basic orientation of the research is an attempting to apply the cost determining method according in the contract sector projects for Al- Iraq ceneral company, that this subject has a big value according to its modernity and its influence on the future and the eaning of the company.
The research aims to find out the effect of the method for determining cost based on the activity in determining the cost of the construction sector projects.The research was conducted in Iraq General Company for the implementation of irrigation projects. Bani search on three assumptions, the first is (that the application of the method for determining the cost on the basis of
... Show MorePolycrystalline Cadmium Oxide (CdO) thin films were prepared using pulsed laser deposition onto glass substrates at room temperature with different thicknesses of (300, 350 and 400)nm, these films were irradiated with cesium-137(Cs-137) radiation. The thickness and irradiation effects on structural and optical properties were studied. It is observed by XRD results that films are polycrystalline before and after irradiation, with cubic structure and show preferential growth along (111) and (200) directions. The crystallite sizes increases with increasing of thickness, and decreases with gamma radiation, which are found to be within the range (23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for thickness 350nm and 4
... Show MoreAt a temperature of 300 K, a prepared thin film of Ag doped with different ratios of CdO (0.1, 0.3, 0.5) % were observed using pulse laser deposition (PLD). The laser, an Nd:YAG in ?=1064 nm, used a pulse, constant energy of 600 mJ ,with a repetition rate of 6 Hz and 400 pulses. The effect of CdO on the structural and optical properties of these films was studied. The structural tests showed that these films are of a polycrystalline structure with a preferred orientation in the (002) direction for Ag. The grain size is positively correlated with the concentration of CdO. The optical properties of the Ag :CdO thin film we observed included transmittance, absorption coefficient, and the energy gap in the wavelength range of 300-1100
... Show MorePolycrystalline Cadmium Oxide (CdO) thin films were prepared
using pulsed laser deposition onto glass substrates at room
temperature with different thicknesses of (300, 350 and 400)nm,
these films were irradiated with cesium-137(Cs-137) radiation. The
thickness and irradiation effects on structural and optical properties
were studied. It is observed by XRD results that films are
polycrystalline before and after irradiation, with cubic structure and
show preferential growth along (111) and (200) directions. The
crystallite sizes increases with increasing of thickness, and decreases
with gamma radiation, which are found to be within the range
(23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for
Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity
... Show More