Preferred Language
Articles
/
ijcpe-92
Extraction of Phenol from Aqueous Solutions Using Bulk ionic Liquid Membranes
...Show More Authors

Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl‐1‐methylimidazoliumhexafluorophosphate[Bmim][PF6],    

   1‐hexyl‐1‐methylimidazoliumhexafluorophosphate[Hmim][PF6], 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide[Bmpyr][NTf2], and 1-octyl-3-methyl imidazolium tetra fluoroborate[Omim][BF4].

   The distribution coefficients for phenol in these ionic liquids were measured at different pH values and found to be much larger than those in conventional solvents. Through the values of the distribution coefficients and the experiments that were conducted on bulk liquid membrane applying various types of prepared ionic liquids, 1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide was selected as the best ionic liquid which gave the highest extraction and stripping efficiencies.

   The effect of several parameters, namely, feed phase pH(2-12), feed concentration(100-1000 ppm), NaOH concentration(0-0.5M), temperature (20-50oC), feed to membrane volume ratio (200-400ml/80ml ionic liquid) and stirring speeds(75-125 rpm) on the performance of the choosen ionic liquid membrane were also studied.    

   The preliminary study showed that high phenol extraction and stripping efficiencies of 97% and 95% respectively were achieved by ionic liquid membrane with a minimum membrane loss which offers a better choice to organic membrane solvents.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
ThermodynamicProperties of Nicotinicacid in Dilute HCl and inaqueous NaCl solutions at (293.15, 298.15, 303.15 and 308.15)K
...Show More Authors

Apparent molar volume, V?, and viscosity B-coefficient of nicotinc acid in water and in aqueous NaCl solutions have been determined from density and viscosity measurements at (293.15, 298.15, 303.15 and 308.15) K. The experimental density data were evaluated by Masson equation, and the derived, apparent molar volume at infinite dilution, Vo?, and the slope Sv, were interpreted in term of solute-solvent and solute- solute interactions. Transfer apparent molar volumes at infinite dilution of nicotinic acid from water to NaCl solutions at various temperatures have been calculated.The viscosity data have been analyzed using Jones-Dole equation, and the derived parameters, Jones-Dolecoefficient, B,and Falkenhagen coefficient,A, have been also in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Engineering And Technology Journal
Study of the Diffusion Coefficient and Hardness for a Composite Material when Immersed in Different Solutions Polymer
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Using Real-Time PCR to Investigate Some of Antibiotic Resistance Genes from Streptococcus agalactiae Isolates from ewe Mastitis cases in Nineveh province
...Show More Authors

In this study, from a total of 856 mastitis cases in lactating ewes, only 34 Streptococcus agalactiae isolates showed various types of resistance to three types of antibiotics (Penicillin, Erythromycin and Tetracycline). St. agalactiae isolates were identified according to the standard methods, including a new suggested technique called specific Chromogenic agar. It was found that antibiotic bacterial resistance was clearly identified by using MIC-microplate assay (dilution method). Also, by real-time PCR technique, it was determined that there were three antibiotics genes resistance ( pbp2b, tetO and mefA ). The high percentage of isolate carried of a single gene which was the Tetracycline (20.59%) followed by percentage Penicillin was

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparative Study of Pressure Losses and Hole Cleaning Efficiency of Water and Polymer solutions in Horizontal Wells
...Show More Authors

The main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 07 2003
Journal Name
University Of Baghdad
A STUDY ON SOLVENT EXTRACTION OF HOLMIUM (III) WITH SUDAN BLACK B REAGENT (M.Sc. Thesis)
...Show More Authors

Preview PDF
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Improvement of Domestic Wastewater Treated Effluent from Sequencing Batch Reactor Using Slow Sand Filtration
...Show More Authors

The effluent quality improvement being discharged from wastewater treatment plants is essential to maintain an environment and healthy water resources. This study was carried out to evaluate the possibility of intermittent slow sand filtration as a promising tertiary treatment method for the sequencing batch reactor (SBR) effluent. Laboratory scale slow sand filter (SSF) of 1.5 UC and 0.1 m/h filtration rate, was used to study the process performance. It was found that SSF IS very efficient in oxidizing organic matter with COD removal efficiency up to 95%, also it is capable of removing considerable amounts of phosphate with 76% and turbidity with 87% removal efficiencies. Slow sand filter efficiently reduced the mass of suspended

... Show More
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Blood Vessels Detection of Diabetic Retinopathy from Retinal Fundus Image using Image Processing Techniques
...Show More Authors

 

Early detection of eye diseases can forestall visual deficiency and vision loss. There are several types of human eye diseases, for example, diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. Diabetic retinopathy (DR) which is brought about by diabetes causes the retinal vessels harmed and blood leakage in the retina. Retinal blood vessels have a huge job in the detection and treatment of different retinal diseases. Thus, retinal vasculature extraction is significant to help experts for the finding and treatment of systematic diseases. Accordingly, early detection and consequent treatment are fundamental for influenced patients to protect their vision. The aim of this paper is to detect blood vessels from

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Nov 14 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Biosorption of Lead, Cadmium and Nickle from Industrial Wast water by Using Dried Macroalgae
...Show More Authors

Biosorpion of lead (Pb), Cadmium (Cd) and Nickl(Ni) by dried biomass of Chara sp. for sample of BMP was used as alternative approach of conventional method. The range of removal percentages was between 92-97%, 70-98.7% and 46.6-96.6% for Pb, Cd and Ni respectively at 3h.Treatment time, with 300-500 mg dried weight from Chara sp. powder at pH 4, with 60 rpm at shaker. FTIR analysis showed the active groups which are responsible for sequestration of heavy metals represented by carboxyl, hydroxyl alkyl, amine and amide. The Biosorption equilibrium experiment for elements showed that the highest sorption percentage for three elements was, Pb 96.6% after 30 minute, for Cd was 100% after 15 minute and 40% to Ni after 75 minute, while the biosorp

... Show More
View Publication Preview PDF
Crossref