Nanocrystalline micro-mesoporous ZSM/MCM-41 composite was synthesized using alkaline treatment method and two step of crystallization in poly tetraflouroethylene (PTFE) lined autoclave. The synthesized zeolites was characterized by X-Ray diffraction (XRD), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), Atomic force microscopy (AFM), Fourier transport infrared (FTIR), and N2 adsorption-desorption (BET). It was approved that the best results for alkaline leaching can be got with 1.5M NaOH solution. High surface (BET) area of 630 m2/g with pore volume of 0.55 cm3/g has been got. AFM reports showed a nano-level size for average particle size of 50nm.
Simplifying formulas that are used for calculations and design are the aim of researchers. For present work, the approach to distinguish the flow under sluice gate was conducted in a laboratory. The extensive experimental program was done to collect fifty-four data points for both free and submerged flow conditions. The data included different discharges, gate openings, flow depths at upstream as well as the flow depths represent a tail water and at a contracted section for downstream. The collected data are analyzed according to a problematic that may encounter in the field, to present a more straightforward (but with acceptable accurate) practical features equations and charts. Based on the proposed formulas, five meth
... Show MoreEntropy generation was studied for new type of heat exchanger (shell and double concentric tubes heat exchanger). Parameters of hot oil flow rate, temperature of inlet hot oil and pressure drop were investigated with the concept of entropy generation. The results showed that the value of entropy generation increased with increasing the flow rate of hot oil and when cold water flow rate was doubled from 20 to 40 l/min, these values were larger. On the other hand, entropy generation increased with increasing the hot oil inlet temperature at a certain flow rate of hot oil. Furthermore, at a certain hot oil inlet temperature, the entropy generation increased with the pressure drop at different hot oil inlet flow rates. Final
... Show Moreشهد العالم مع بداية القرن الحادي والعشرين تدشين مرحلة جديدة من التطور شملت مختلف الميادين لاسيما في مجال التطورات العلمية والثورة المعلوماتية.. كما إن مسار الديمقراطية في بعض دول العالم يصبح سالكا خاصة في تركيا, فمنذ اواسط الثمانينيات من القرن الماضي فتح المجال السياسي امام قوى كانت مسحوقة ومهمشة, ويكاد ان لا يكون لها وجود في الحياة السياسية للنزول الى ساحة العمل السياسي اسوة ببقية القوى ا
... Show MoreThe wall of the esophagus in Mabuya aurata septemaeniata as in high vertebrates consists of four layers, mucosa, submucosa,muscularis and serosa. Mucosa forms many unorganized short and long folds penetrate inside the esophageal cavity. Mucosa contains two sub layers, first one is lining epithelium which includes two types of cells, simple ciliated columnar epithelial cells and goblet cells, second one is lamina properia. Mucosa does not have muscularis mucosa. There is no esophageal glands within esophagus. Many special stains were used as (Periodic Acid Schiff (PAS)) to detect Carbohydrates in goblet cells. Alcian blue were used to detect the amount of goblet cells within lining epithelium. Alcian blue + PAS together confirm that the
... Show Morethe sera levels of luteninizing hormone were investgaited prior tq surgery in 10 postmenopaisal women with benign and 10 postmenopausal women with maliganant healthy
Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride (TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 μg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in its commercial formulations.
