The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained. Langmuir and Freundlich isotherms were presumed to fit the batch kinetics data for the sorption of Cd(II) onto ZVAI and/or ZVI and found that Langmuir (I) was the most representative model type with coefficient of determination R2 greater than 0.9115. Kinetics data for the sorption of Cd(II) onto ZVAI/ZVI mixture and due to the good agreement between the fitted and the experimental results; the data was found to obey the pseudo second order model. The scanning electron microscopy (SEM) for the ZVI and ZVAI was conducted before and after the sorbent-liquid reaction and revealed distinct morphological changes in the sorbent surface due to the contaminant saturation and pore channel blockages that ceased the sorption process.
Simvastatin (SIM), is an inactive lactone, anti-hyperlipidemic drug. The drug belongs to the class II group according to the biopharmaceutical classification system (BCS) with low bioavailability due to its low solubility. Adsorption technique is an effective technique for improving the solubility and dissolution rate of poorly soluble drugs by using the mesoporous silica. The present study aims to enhance the solubility and dissolution rate of SIM using such technique. Soluplus® and poloxamer 407 were used as surfactants besides magnesium aluminum silicate (MAS) as adsorbent. All the MAS loading SIM formulations were prepared by the solvent evaporation method in different drug: adsorbent: surfactant weight ratios, then evaluated f
... Show MoreThree types of medical commercial creams Silvazine, Cinolon Tar and Hydroquinon Domina were incorporated in this study. The medical creams were taken directly and placed uniformly on the glass slide. Each type of pharmaceutical was weighed at 1 mg and dispersed on an area of 1x1 cm. This process ensures same thickness for all samples. The creams were analyzed by using double-beam UV/visible spectrophotometer Metertech SP8001. The absorption spectrum for each of samples was measured against wavelength range of 300–700 nm.
In the present study, the removal of zinc from synthetic waste water using emulsion liquid membrane extraction technique was investigated. Synthetic surfactant solution is used as the emulsifying agent. Diphenylthiocarbazon (ditizone) was used as the extracting agent dissolved in carbon tetrachloride as the organic solvent and sulfuric acid is used as the stripping agent. The parameters that influence the extraction percentage of Zn+2 were studied. These are the ratio of volume of organic solvent to volume of aqueous feed (0.5-4), ratio of volume of surfactant solution to volume of aqueous feed (0.2-1.6), pH of the aqueous feed solution (5-10), mixing intensity (100-1000) rpm, concentration of extracting agent (20-400) ppm, surfactant co
... Show MoreKidney damage in workers within environments of highly expected exposure to toxin, including heavy metals, could be a primary marker to expect hazards in population exposed to low levels of many environmental pollutants. The present study was designed to evaluate the possible effect of environmental exposure to cadmium and zinc on renal function among painters in Sulaimani city. Cross sectional study was performed on 37 male painting workers in Sulaimani city. Each worker was interviewed using structured questionnaire. Twenty five non-exposed healthy subjects were included as control group. Venous blood samples (10 ml) were obtained by vein puncture from both subjects and utilized for estimation of serum urea, creatinine levels, serum le
... Show MoreThis study is conducted to determine the activity of plant Vica faba and two isolated from arbuscular mycorrhizae fungi (A,B) in bioremediation of soil pollution by Nickel and Lead elements in north and south of Baghdad city. The results showed that the average of soil pollution by Nickel and Lead elements in north of Baghdad was less than the average of soil pollution in the south of Baghdad which recorded 29.0,9.0PPm and 42.0, 25.0PPm respectively. The results show that the isolate A from the polluted soil is more active from isolate B which isolate from unpolluted soil for bioremediation. Vica faba recorded more in accumulate the Lead element in shoot system which was 19.65PPm and in root system was 27.2PPm and for Nickel element 24.65
... Show MoreCharacterizing dementia is a global challenge in supporting personalized health care. The electroencephalogram (EEG) is a promising tool to support the diagnosis and evaluation of abnormalities in the human brain. The EEG sensors record the brain activity directly with excellent time resolution. In this study, EEG sensor with 19 electrodes were used to test the background activities of the brains of five vascular dementia (VaD), 15 stroke-related patients with mild cognitive impairment (MCI), and 15 healthy subjects during a working memory (WM) task. The objective of this study is twofold. First, it aims to enhance the recorded EEG signals using a novel technique that combines automatic independent component analysis (AICA) and wave
... Show MoreThe absorption spectrum for three types of metal ions in different concentrations has been studying experimentally and theoretically. The examination model is by Gaius model in order to find the best fitting curve and the equation controlled with this behavior. The three metal ions are (Copper chloride Cu+2, Iron chloride Fe+3, and Cobalt chloride Co+2) with different concentrations (10-4, 10-5, 10-6, 10-7) gm/m3. The spectroscopic study included UV-visible and fluorescence spectrum for all different concentrations sample. The results refer to several peaks that appear from the absorption spectrum in the high concentration of all metal ions solution.
... Show More