In petroleum industry, the early knowledge of “pore pressure gradient” is the basis in well design and the extraction of these information is more direct when the pore pressure gradient is equal to normal gradient; however, this matter will be more complex if it deviate from that limit which is called “abnormal pore pressure”, if this variable does not put in consideration, then many drilling problems will occur might lead to entire hole loss. To estimate the pore pressure gradient there are several methods, in this study; Eaton method’s is selected to extract the underground pressure program using drilling data (normalized rate of penetration) and logs data (sonic and density log). The results shows that an abnormal high pressure is observed in Lower Fars formation started from Mb5 member as a transition zone and increase gradually until reach the Mb4 member and continuous to Mb3 and Mb2 then begin to decrease from Mb1 which is consider a transition zone between high pore pressure zone and sub-pressure zone represented by Jeribe-Euphrate and Upper Kirkuk formations and back to normal pore pressure at Middle-Lower Kirkuk formation. The dc-exponent method has been selected in estimating pore pressure gradient and considers the best one compared with logs data methods.
We present the notion of bipolar fuzzy k-ideals with thresholds (
Femtosecond laser pulse propagation in monomode optical fibers is demonstrated and investigated numerically (by simulations) and experimentally in this paper. A passively mode locked Nd:glass laser giving a pulse duration of about 200 fsec at 1053 nm wavelength and 120 mW average optical power with 100 MHz repetition rate is used in the experimental work. Numerical simulations are done by solving the nonlinear Schrödinger equation with the aid of Matlab program. The results show that self phase modulation (SPM) leads to compression of the spectral width from 5 nm to 2.1 nm after propagation of different optical powers (34, 43, 86 and 120 mW) in fibers of different length (5, 15, 35 m). The varying optical powers produced a varying
... Show MorePurpose: To validate a UV-visible spectrophotometric technique for evaluating niclosamide (NIC) concentration in different media across various values of pH. Methods: NIC was investigated using a UV-visible spectrophotometer in acidic buffer solution (ABS) of pH 1.2, deionized water (DW), and phosphate buffer solution (PBS), pH 7.4. The characterization of NIC was done with differential scanning calorimeter (DSC), powder X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The UV analysis was validated for accuracy, precision, linearity, and robustness. Results: The DSC spectra showed a single endothermic peak at 228.43 °C (corresponding to the melting point of NIC), while XRD and FTIR analysis confirmed the identit
... Show MoreIn this work, a simulated study was carried out for designing a novel spiral rectangular patch of microstrip antenna that is used in ultra-wideband applications by using a high frequency structure simulator software (HFSS). A substrate with dielectric constant of 4.4 and height 2.10 mm (commercial substrate height available is about 0.8-1.575 mm) has been used for the design of the proposed antenna. The design basis for enhancing bandwidth in the frequency range 6.63 - 10.93 GHz is based on increasing the edge areas that positively affect the antenna's efficiency. This design makes the designed antenna cost less by reducing the area of the patch. It has been noticed that the bandwidth of the antenna under this study is increasing to 4.30
... Show MoreSimple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets
A major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For
Genus Salix is among family Salicaceae, distributing in the northern hemisphere. It is represented in Egypt by two species (Salix mucronata and Salix tetrasperma). The classification of Salix at the generic and infra-generic levels is still outstanding. We have agreed to list the Egyptian species of this genus. We collected them during field trips to most Egyptian habitats; fresh and herbarium specimens were subjected to taxonomic revision based on morphological characters; scanning electron microscope (SEM) for pollen grains; isozyme analysis using esterase and peroxidase enzymes and genetic diversity using random amplified polymorphic DNA (RAPD). We recorded that both sexes of S.
Software-defined networking (SDN) presents novel security and privacy risks, including distributed denial-of-service (DDoS) attacks. In response to these threats, machine learning (ML) and deep learning (DL) have emerged as effective approaches for quickly identifying and mitigating anomalies. To this end, this research employs various classification methods, including support vector machines (SVMs), K-nearest neighbors (KNNs), decision trees (DTs), multiple layer perceptron (MLP), and convolutional neural networks (CNNs), and compares their performance. CNN exhibits the highest train accuracy at 97.808%, yet the lowest prediction accuracy at 90.08%. In contrast, SVM demonstrates the highest prediction accuracy of 95.5%. As such, an
... Show More