Preferred Language
Articles
/
ijcpe-478
Corrosion Inhibition of Carbon Steel under Two Phase Flow (Water-Petroleum) Simulated by Turbulently Agitated System
...Show More Authors

The corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding  to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of inhibitors: sodium nitrite of concentrations 20, 40, and 60 ppm and sodium hexapolyphosphate of concentrations 485, 970, and 1940 ppm in a solution containing 8 % vol. aqueous phase (water) mixed with kerosene (continuous phase) at 40 °C for the whole range of Re. It was found that increasing Re increases the corrosion rate and the presence of water enhances the corrosion rate by increasing the solution electrical conductivity. For two phase solution containing 8% vol. and 16% vol. of water the corrosion rate was higher than single phase (100 % vol. water). The main parameters that play the major role in determining the corrosion rate in two phase were concentration of oxygen, solution electrical conductivity,  and the interfacial area between the two  phases (dispersed and continuous). Sodium nitrite and sodium  hexapolyphosphate were found to be efficient inhibitors in two phase solutionfor  the investigated range of Re.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
Select the optimal project by using two methods of analytic hierarchy and goal programming
...Show More Authors

      The aim of this research is to solve a real problem in the Department of Economy and Investment in the Martyrs establishment, which is the selection of the optimal project through specific criteria by experts in the same department using a combined mathematical model for the two methods of analytic hierarchy process and goal programming, where a mathematical model for goal programming was built that takes into consideration the priorities of the goal criteria by the decision-maker to reach the best solution that meets all the objectives, whose importance was determined by the hierarchical analysis process. The most important result of this research is the selection of the second pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reduction of Sulfur Compounds from Petroleum Fraction Using Oxidation-Adsorption Technique
...Show More Authors

Oxidation of sulfur compounds in fuel followed by an adsorption process were studied using two modes of operation, batch mode and continuous mode (fixed bed). In batch experiment oxidation process of kerosene with sulfur content 2360 ppm was achieved to study the effect of amount of hydrogen peroxide(2.5, 4, 6 and 10) ml at different temperature(40, 60 and 70)°C. Also the effect of amount acetic acid was studied  at the optimal conditions of the oxidation step(4ml H2O2 and 60 °C).Besides, the role of acetic acid different temperatures(40, 60, 70) °C and 4ml H2O2, effect of reaction time(5, 30, 60, 120, 300) minutes at temperatures(40,60) °C, 4ml H2O2 and 1 mlHAC)&

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Petroleum Derivatives in Iraq The phenomenon of Renewable or Passing crisis
...Show More Authors

     Iraq economy suffered, nor , still many difficulties and problems , including oil derivatives crisis that emerged in 2004 and was the most prominent features of the inability of local production to meet the needs of the increasing growth of consumption, the crisis has cast a shadow on the growth of national in general, and citizen living in particular. Therefore, the real test of crisis and challenge to the capacity of government agencies to manage the crisis and control and reduce its harmful effects, which disappear in a region or sector, even begin to appear in another, given the multiplicity and complexity of third-party solution for remedying the negative consequences of deliberate.

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Evaluation of Heavy Metals Content in Simulated Solid Waste Food Compost
...Show More Authors

Composting is one of the solid waste management (SWM) methods where the organic component decomposed biologically under controlled conditions. In this study, a 0.166 m3 bioreactor tank was designed to compose 59.2Kg of simulated common municipal solid food waste having a bulk density, organic matter, organic carbon, pH, nitrogen content, C/N and nitrification index (NH4-N/ NO3-N) of 536.62 kg/m3, 62.34%, 34.76%, 6.53, 1.86%, 23 and 0.34 respectively. The bioreactor operated aerobically for 30 days, and anaerobically for 70 days, until the end of the composting process. Results proved that the composting process could reduce the mass of the waste by 69%.  Nitrogen content,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (15)
Scopus Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Removal of Cadmium Ions from Simulated Wastewater Using Rice Husk Biosorbent
...Show More Authors

Biosorption of cadmium ions from simulated wastewater using rice husk was studied with initial concentration of 25 mg/l. Equilibrium isotherm was studied using Langmuir, Freundlich, BET and Timken models. The results show that the Freundlich isotherm is the best fit model to describe this process with high determination coefficient equals to 0.983. There was a good compliance between the experimental and theoretical results. Highest removal efficiency 97% was obtained at 2.5g of adsorbent, pH 6 and contact time 100 min.

View Publication Preview PDF
Crossref
Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication
Publication Date
Fri Oct 06 2023
Journal Name
Journal Of Electrochemical Science And Engineering
Zinc (II) removal from simulated wastewater by electro-membrane extraction approach: Adopting an electrolysis cell with a flat sheet supported liquid membrane
...Show More Authors

The aim of this study is to utilize the electromembrane extraction (EME) system as a manner for effective removal of zinc from aqueous solutions. A novel and distinctive electrochemical cell design was adopted consisting of two glass chambers, a supported liquid membrane (SLM) housing a polypropylene flat membrane infused with 1-octanol and a carrier. Two electrodes were used, a graphite as anode and a stainless steel as cathode. A comprehensive examination of several influential factors including the choice of carrier, the applied voltage magnitude, the initial pH of the donor solution, and the initial concentration of zinc was performed, all in a concerted effort to ascertain their respective impacts on the efficiency of zinc elim

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Energy Generation from Static Water Head Developed By Forward Osmosis
...Show More Authors

In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Desalination And Water Treatment
Reducing endotoxin from dialysis water by using different disinfection processes
...Show More Authors

View Publication
Scopus (7)
Crossref (5)