Collapse of the vapor bubble condensing in an immiscible is investigated for n-pentane and n-hexane vapors condensing in cold water and n-pentane in two different compositions of glycerin- water mixture. The rise velocity and the drag coefficient of the two-phase bubble are measured.
Hydrate dissociation equilibrium conditions for carbon dioxide + methane with water, nitrogen + methane with water and carbon dioxide + nitrogen with water were measured using cryogenic sapphire cell. Measurements were performed in the temperature range of 275.75 K–293.95 K and for pressures ranging from 5 MPa to 25 MPa. The resulting data indicate that as the carbon dioxide concentration is increased in the gas mixture, the gas hydrate equilibrium temperature increases. In contrast, by increasing the nitrogen concentration in the gas mixtures containing methane or carbon dioxide decreased the gas hydrate equilibrium temperatures. Furthermore, the cage occupancies for the carbon dioxide + methane system were evaluated using the Van der Wa
... Show Morenumber of neonatal mortality rate (NMR). This study was conducted to clarify the relationship between conflict and neonatal mortality in Baghdad, Iraq.
Objective: Throw a light on the impact of conflicts on neonatal mortality in Iraq.
Methods: This cross-sectional study was carried out in two hospitals in Baghdad that were chosen randomly. All deceased newborns in neonatal intensive care units from January 2012 to December 2016 in the mentioned hospitals were included in this study.
Results: The admissions were increased during the period of the study by 1.3 times. There was a decrease in admission by 0.9 in 2016 than 2015. There was an increase in NMR during the period of the study by 1.4 times, from 60/1000 in 2012 to 85/1000
Background: Strain imaging assessing regional myocardial deformation and can be used to quantify regional myocardial function and differentiate between ischemic and non ischemic myocardium.
Objectives: to assess sensitivity and specificity of strain imaging in detection of coronary artery disease in comparison with coronary angiography.
Patients and Methods: ninety six patients were referred to Ibn albitar center for cardiac surgery, Baghdad, Iraq with symptoms of coronary artery disease for a period between June 2014 and April 2015, all of whom were evaluated by two dimensional echocardiography and all were found to have good left ventricular systolic function with no regiona
In this work, calculation of pressure losses in circulating system for two drilling muds is evaluated in Noor oil field. Two types of drilling muds that were used for drilling section 12 1/4" and 8 3/4" which are Salt saturated mud and Ferro Chrome Lignosulfonate-Chrome Lignite mud. These calculations are based on field data that were gathered from the drilling site of well Noor-15, which are included, rheological data, flow data and specification of drill string. Based on the obtained results, the best rheological model that fit their data is the Herschel-Bulkley model according to correlation coefficient value for their two drilling mud. Also, the difference between the calculated pressure lo
... Show MoreThe purpose of this research paper is to present the second-order homogeneous complex differential equation , where , which is defined on the certain complex domain depends on solution behavior. In order to demonstrate the relationship between the solution of the second-order of the complex differential equation and its coefficient of function, by studying the solution in certain cases: a meromorphic function, a coefficient of function, and if the solution is considered to be a transformation with another complex solution. In addition, the solution has been provided as a power series with some applications.
This study aimed to detect the present levels and distribution of air pollutants such as SPM, Pb, Cr, Cd , and Ni , in two urban sites within Al- Rusafa side in Baghdad city (Al-Waziriya as industrial site and Al-Andalus square as commercial site). Measurements were carried out from November 2013 until June 2014. SPM, Pb, Cr, Cd , and Ni were measured using Air intake device(Sniffer) . The average minimum concentrations of SPM, Pb, Cr, Cd , and Ni were 588 μg/m3, 2.8 μg/m3, 15.6 μg/m3, 0.1 μg/m3, and 6.3 μg/m3. While the average maximum concentrations were 723 μg/m3 , 3.4 μg/m3 , 21.7 μg/m3 , 0.125 μg/m3 , and 6.8 μg/m3 , respectively. The results indicate that commercial site was more polluted with SPM , Pb , and Ni compared t
... Show MoreA biological experirne.rit was CQhducted ·ll1 the (Ibn- AlÂ
Haitham). University of Baghdad for growing seasens on of
2004/2005 (by using gypsum soil taken from Al- Doar area I Salah Al Dean provinc) to stucl·- the effect three levels of phosphorus (0, 400,
SOO)rng ! pot and four levels of zinc (0, 10,.. J 5, 2.0) tngf I pot on some
features of two varieties -Qf wheat, (triticum aestivurn var. rateh)and
(Triticum aestiv1lm Var. Ipa 99)..
R't
... Show MoreThe flow emission rate of hard photons from lowest order the QCD processes for quark-anti quark annihilation processes in plasma media at high temperatures (175, 200, 225, 250 and 275 MeV) have been study. In these framework photons, the flow photons emission is calculate according to quark-antiquark annihilation using the quantum chromodynamic theory and solves the ultrarelativistic equation with MATLAP program. Due to the results, we show increases flow photons rate with increases strength coupling and increases with increases temperature of media, it indicate that logarithmically divergent thermal effect on photons product. The critical temperature (Tc=155 to 195 MeV) effect on the quarks confined in hadronic matter phase, it is importan
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show More