Experimental and theoretical investigations are presented on flocculation process in pulsator clarifier. Experimental system was designed to study the factors that affecting the performance of pulsator clarifier. These factors were water level in vacuum chamber which range from 60 to 150 cm , rising time of water in vacuum chamber which having times of 20,30 & 40 seconds , and sludge blanket height which having heights of 20,30 & 40 cm .The turbidity and pH of raw water used were 200 NTU and 8.13 respectively. According to the jar test, the alum dose required for this turbidity was 20 mg/l .The performance parameters of pulsator clarifier such as , turbidity ,total solid TS , shear rate , volume concentration of sludge blanket and the flocculation criteria were studied. It was observed that by decreasing the water level in vacuum tube and by increasing the rising time and sludge blanket height , low turbidity of output water attained. Moreover, flocculation criteria value GCt was within the optimum range values (100-500) .A theoretical models was applied for total solids TS of output water .The difference between experimental and theoretical data was ranged between (11-24)% of mean deviation at water level range of (125-150)cm and sludge blanket height 20 cm.
ABSTRACT The antibacterial and antbiofilm activities of water extract of Calendula officinalis flowers against some of enteropathogenic bacteria was studied, also phytochemical screening and determination of antioxidant activity of the extract has been investigated. The results showed that the water extract of C. officinalis exhibited a good antibacterial activity against all pathogenic bacterial isolates (Salmonella, Shigella dysenteriae, Shigella flexneri, Shigella sonnei and E. coli) especially at concentration 100 µg/ml in contrast with the control cefotan antibiotic. S. sonnei was more sensitive to extract than other bacteria with highest inhibition zone (23 mm). The preliminary phytochemical tests results indicated the presence
... Show MoreAbstract Objectives: Malocclusion was and remains one of the most common problems which affects the psyche and social status of the individual, so the estimation of the malocclusion severity and needs a percentage of orthodontic treatment of Iraqi patients is the aim of this study. Method: A randomly selected 150 pairs of study models (48 male and 102 female) were involved in this study for patients attending an orthodontic clinic at College of Dentistry/ University of Baghdad seeking for treatment. The DAI scores were collected according to WHO guidelines directly from the study model with a digital caliper, score was calculated using the regression equation of 10 occlusal traits. The dental casts were classified into four groups to determ
... Show MoreThin films of the blended solution of (NiPc/C60) on glass substrates were prepared by spin-coated method for three different ratios (100/1, 100/10 and 100/100). The effects of annealing temperature and C60 concentration on the optical properties of the samples were studied using the UV-Vis absorption spectroscopy and FTIR spectra. The optical absorption spectrum consists of two main bands, Q and B band, with maxima at about (602-632) nm and (700-730) nm for Q1 and Q2 respectively, and (340-375) nm for B band. The optical energy gap were determined from optical absorption spectra, The variation of optical energy gap with annealing temperature was nonsystematic and this may be due to the improvement in crystal structure for thin films. Whi
... Show MoreAnaerobic digestion (AD) is the most common process for dealing with primary and secondary wastewater sludge. In the present work, four pre-treatment methods (ultrasonic, chemical, thermal, and thermo-chemical) are investigated in Al-Rustumya Wastewater Treatment plant in order to find their effect on biogas production and volatile solid removal efficiency during anaerobic digestion.
Two frequencies of ultrasonic wave were used 30 KHz and 50 KHz during the pre-treatment. Sodium hydroxide was added in different amounts to give three pH values of 9, 10 and 11 in chemical pre-treating processes. The sludge was heated at 60oC and 80oC through thermal pre-treatment experiment. Also, the sludge was treated thermo-chemically at 80 oC and pH
A specific, sensitive and new simple method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation of ion pair compound between methyldopa and potassium hexacyanoferrate in acidic medium to obtain a yellow precipitate complex using long distance chasing photometer (NAG-ADF-300-2). The linear range for calibration graph was 0.05-35 mmol/L for cell A and 0.05-25 mmol/L for cell B, and LOD 1.4292 µg /200 µL for both cells with correlation coefficient (r) 0.9981 for cell A and 0.9994 for cell B, RSD% was lower than 0.5 % for n=8 for. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbi
... Show MoreThis study is aimed to use the aerobic packed bed in biotreatment of the wastewater which is discharge from AL-KARAMA teaching hospital in Baghdad. The performance of packed-bed treatment method was examined for elimination of the organic compounds from wastewater under aerobic conditions. In this research different parameters were studied. They were: inoculums concentration, circulation rate of wastewater through the bed, packing type and the temperature. Results showed that the system efficiently removed about 82% of the chemical oxygen demand (COD) and 80% of the Biological oxygen demand (BOD). Percent reduction in turbidity was about 92% and reduction in nitrate concentration was about 87%. It was found that best performance of the pack
... Show MoreIn this paper, the experiments were carried out in laboratory flotation cell treating solid fines. The effect of variables such as collector oil dosage, pine oil dosage and solid content of the feed slurry have been investigated on the flotation characteristics of low rank coal. Attempts have also been made to develop some empirical Eq. to predict the yield and ash content of concentrate with the operating variables, solids concentration, collector oil dosage, and pine oil dosage, to estimate the recovery at any operating conditions. The calculated results obtained from regression equation by correlating the variables with the yield and ash content of concentrate have been compared to study whether calculated values match closely with th
... Show MoreEffect of Chlorococcum humicola alcoholic algae extract was studied on the growth of, Pseudomonas aeruginosa, and Klebsiella pneumonia, which were isolated from contaminated water. The extract of Ch. humicola showed a high efficiency in reducing the numbers of the two types of bacteria. . The removal rate of K. pneumonia were 0.0, 48.4 and 57.0, The removal rate of P. aeruginosa were 63.1, 79.8 and 82.9% after24,48, 72 h respectively. The results improved that the K. pneumonia is more sensitive than P. aeruginosa for algae extract concentrations used in study ,and the beast effective time is 24h for the two bacterial species The aim of the study was to eliminate microorganisms using the Alcoholic algae extract. Especially P. aeruginosa and
... Show MoreIn recent years, the search for economic and environmentally friendly alternatives has become a global necessity to achieve sustainability and preserve raw materials. From this concept, natural bitumen (NB) derived from sulphur springs is now one of the most promising alternative energy resources for many applications, especially in asphalt pavement construction. Its low price and abundance characterise NB since sulphur springs produce thousands of tonnes of NB annually and are used in very limited fields. Two main objectives were adopted for this work. The first objective is to examine the virgin NB properties from five sulphur springs and compare them with petroleum asphalt. The second objective is to enhance NB properties by appl
... Show MoreThe approach of the research is to simulate residual chlorine decay through potable water distribution networks of Gukookcity. EPANET software was used for estimating and predicting chlorine concentration at different water network points . Data requiredas program inputs (pipe properties) were taken from the Baghdad Municipality, factors that affect residual chlorine concentrationincluding (pH ,Temperature, pressure ,flow rate) were measured .Twenty five samples were tested from November 2016 to July 2017.The residual chlorine values varied between ( 0.2-2mg/L) , and pH values varied between (7.6 -8.2) and the pressure was very weak inthis region. Statistical analyses were used to evaluated errors. The calculated concentrations by the calib
... Show More