Kinetics study on the phenol oxidation by catalytic wet air oxidation (CWAO) using CuO.NiO/Al2O3 as heterogeneous catalyst is presented. 4 g/l phenol solution of pH 7.3 was oxidized in a trickle bed reactor with gas flow rate of 80% stochiometric excess (S.E).. In order to verify the proposed kinetics, a series of CWAO experimental tests were done at two temperatures (140 and 160° C), oxygen partial pressures (9 and 12 bar), and weight hourly space velocity (WHSV) (1, 1.5, 2, 2.5, and 3 h-1). According to Power Law, the reaction orders are found to be approximately 1 and 0.5 with respect to phenol concentration and oxygen solubility, respectively. These values favorably compare with those cited in the literature for intrinsic kinetics, which indicates minimal mass transfer limitations in the trickle bed reacting system used in this study.
This study aims to characterize traumatic spinal cord injury (TSCI) neurophysiologically using an intramuscular fine-wire electromyography (EMG) electrode pair. EMG data were collected from an agonist-antagonist pair of tail muscles of Macaca fasicularis, pre- and post-lesion, and for a treatment and control group. The EMG signals were decomposed into multi-resolution subsets using wavelet transforms (WT), then the relative power (RP) was calculated for each individual reconstructed EMG sub-band. Linear mixed models were developed to test three hypotheses: (i) asymmetrical volitional activity of left and right side tail muscles (ii) the effect of the experimental TSCI on the frequency content of the EMG signal, (iii) and the effect
... Show MoreBackground: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoT
... Show MoreThis paper studies the oscillation properties and asymptotic behavior of all solutions of the 2×2 system of second-order half-linear neutral differential equations. Four results are obtained in this research. The first and second results are auxiliary results while the third and fourth results are main results. All possible cases of non-oscillating bounded solutions for this system are estimated and analyzed. It is noted that the parameters that affect the volatility of the solutions are Qi,Ri on the one hand and r1 and r2 on the other hand. For this purpose, and through investigation, it is shown that there are only fourteen possible cases of non-oscillating bounded solutions for this system, so all these cases must be treated, in the fir
... Show MoreAbstract:In this paper, some probability characteristics functions (moments, variances,convariance, and spectral density functions) are found depending upon the smallestvariance of the solution of some stochastic Fredholm integral equation contains as aknown function, the sine wave function
Introduction The Hybrid Gamma Camera (HGC) is being developed to enhance the localisation of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. Purpose To assess the capability of the HGC, a lymph-node-contrast (LNC) phantom was constructed for an evaluative study simulating medical scenarios of varying radioactivity concentration and SLN size. Materials and methods The phantom was constructed using two methyl methacrylate PMMA plates (8 mm thick). The SLNs were simulated by drilling circular wells of diameters ranging between 10 mm and 2.5 mm (16 wells in total) in one plate. These simulated SLNs were placed underneath scattering material with thicknesses ranging between 5 mm
... Show MoreArt is a language in which the artist expresses himself, his society, and the events he lives in, so new artistic trends emerged, so the artist no longer practices his art as required by any previous artistic rules. And the thoughts wandering inside him, which led him to the abstract method in which the artist tries to employ the elements of the artwork in a plastic construction through which he achieves the relationships of the abstract form through the rhythms of lines, colors, spaces, shapes and textures without these plastic elements having any connection with the visual reality.
The research aims to find a new vision inspired by the school of geometric abstraction to enrich the field of Saudi plastic painting. And to take advan
Objective: to evaluate the increase in weight after biological agents and the association of weight gain with the body mass index among a sample of patients attending Baghdad Teaching Hospital Methods: A prospective study is carried out in Baghdad teaching hospital biological units and outpatient clinic of rheumatology for a period of one year starting On April 2015 and ending on March 2016. 120 patients were included in the study 40 psoriatic arthritis .40 ankylosing spondylitis and 40 rheumatoid arthritis Results : The study findings indicate that significance differences are seen regarding weight gain and b
In this paper, we investigate the basic characteristics of "magnetron sputtering plasma" using the target V2O5. The "magnetron sputtering plasma" is produced using "radio frequency (RF)" power supply and Argon gas. The intensity of the light emission from atoms and radicals in the plasma measured by using "optical emission spectrophotometer", and the appeared peaks in all patterns match the standard lines from NIST database and employed are to estimate the plasma parameters, of computes electron temperature and the electrons density. The characteristics of V2O5 sputtering plasma at multiple discharge provisos are studied at the "radio frequency" (RF) power ranging from 75 - 150 Wat
... Show More