The unsteady state laminar mixed convection and radiation through inclined
cylindrical annulus is investigated numerically. The two heat transfer mechanisms of
convection and radiation are treated independently and simultaneously. The outer
cylinder was kept at a constant temperature while the inner cylinder was heated with
constant heat flux. The study involved numerical solution of the governing equations
which are continuity, momentum and energy equations using finite difference method
(FDM), where the body fitted coordinate system (BFC) was used to generate the grid
mesh for computational plane. A computer program (Fortran 90) was built to calculate
the bulk Nusselt number (Nub) after reaching steady state condition for fluid Prandtl
number fixed at (Pr =0.7) (for air) with radius ratio ( =1.5, 2.6, 5.0), Rayleigh number
(0≤Ra≤103),Reynolds number (50≤Re≤2000), dimensionless heat generation (0≤Q≤10),
Conduction-Radiation parameter (0≤N≤10), optical thickness (0 ≤ t
≤ 10) and different
annulus inclination with horizontal plane (0°≤δ≤90°). For the range of parameters
considered, results show that radiation enhance heat transfer. It is also indicated in the
results that Nu increase with the increasing of inclination angle δ, Ra, Re, and Q. The
correlation equations are concluded to describe the radiation effect.
Comparison of the result with the previous work shows a good agreement.
Titanium alloy surface properties have an essential role in the interaction of dental implants with bone, and alteration of the surface of the implant could improve osseointegration. This study was designed to investigate the effect of different heat treatment temperatures on titanium alloy surface properties for dental implants. The effect of different temperatures of heat treatment (750°C, 850°C, 950°C and 1050°C) were investigated on the surface topography, surface chemistry, titanium oxide layer thickness, blood contact angle, & blood drop diameter of titanium alloy. The disks were prepared from titanium alloy (Ti-6Al-4V) and the samples were divided into five groups depending on the different temperatures of heat treatment. The hea
... Show More
The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c
... Show MoreThe efficiency of internal combustion engines (ICE) is usually about thirty percent of the total energy of the fuel. The residual energy is lost in the exhaust gas, the lubrication, and the cooling water in the radiators. Recently much of the researcher’s efforts have focused on taking advantage of wasted energy of the exhaust gas. Using a thermoelectric generator (TEG) is one of the promising ways. However, TEG depends entirely on the temperature difference, which may be offered by the exhaust muffler. An experimental test has been conducted to study the thermal performance of a different muffler internal design. The researchers resort to the use of lost energy in an ICE using TEG, which is one of the ways to take adv
... Show MoreIn this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.
An experimental study was carried out to estimate the performance of cooling system, where som
... Show MoreThe process of transporting waste from urban areas to sanitary landfill sites requires large amounts of money due to the length and distance. To address this problem, temporary transfer stations were established by the Municipality of Baghdad to reduce the cost of transportation, and for the purpose of preserving the environment in a sustainable manner, standards were set for the establishment of these stations. The two stations of Al-Karrada Municipality and Al-Shula Municipality were chosen as a case study to measure the extent of adopting and applying the standards for establishing substations locally, regionally and internationally, and the most important results were reached Which is that the transforming (regular) stations of the t
... Show MoreEmulsion Liquid Membrane (ELM) is an emerging technology that removes contaminants from water and industrial wastewater. This study investigated the stability and extraction efficiency of ELM for the removal of Chlorpyrifos Pesticide (CP) from wastewater. The stability was studied in terms of emulsion breakage. The proposed ELM included n-hexane as a diluent, span-80 as a surfactant, and hydrochloric acid (HCl) as a stripping agent. Parameters such as mixing speed, aqueous feed solution pH, internal-to-organic membrane volume ratio, and external-to-emulsion volume ratio were investigated. A minimum emulsion breakage of 0.66% coupled with a maximum chlorpyrifos extraction and stripping efficiency were achieved at 96.1% and 95.7% at b
... Show MoreThe present study was conducted to investigate the effect of adding various levels of Optifeed®, VêO® premium and Oleobiotec® to the diets as appetite stimulants in the production Performance of broiler males under heat stress conditions. The experiment was done for 42 days for the period from 30 August 2018 to 11 of October 2018 at the Poultry Research Station of the Livestock Research Department / Agricultural Research Department / Ministry of Agriculture (Baghdad - Abu Ghraib). In this study, 270 - one-day broiler males (Ross 308) were reared with the mean body weight of 37 g/chick, distributed randomly on 18 pens with dimensions of 2 x 3 m (length x width). The experimental treatments involved six treatments with three repli
... Show MoreBy reading the book (Endless Forms Most Beautiful: The New Science of Evo Devo) by Sean B. Carroll, new horizons opened up about the nature of the formation of the living organism. Although he presented the idea that the artist was influenced by the material assets of nature in his holographic art formations, the new science of Evo-Devo (Evolutionary Developmental Science) provided models worth standing on when comparing the similarity of the formation of living organisms on the one hand, and the formation of works of art with holographic organic bodies on the other. But the excitement lies in the fact that the formation of living natural organisms is often driven by subtle intelligent mechanisms that are different from the mechanisms us
... Show MoreSorption is a key factor in removal of organic and inorganic contaminants from their aqueous solutions. In this study, we investigated the removal of Xylenol Orange tetrasodium salt (XOTS) from its aqueous solution by Bauxite (BXT) and cationic surfactant hexadecyltrimethyl ammonium bromide modified Bauxite (BXT-HDTMA) in batch experiments. The BXT and BXT-HDTMA were characterized using FTIR, and SEM techniques. Adsorption studies were performed at various parameters i.e. temperature, contact time, adsorbent weight, and pH. The modified BXT showed better maximum removal efficiency (98.6% at pH = 9.03) compared to natural Bauxite (75% at pH 2.27), suggesting that BXT-HDTMA is an excellent adsorbent for the removal of XOTS from water. The equ
... Show More