Preferred Language
Articles
/
ijcpe-313
Reverse Osmosis Polyamide Membrane for the Removal of Blue and Yellow Dye from Waste Water
...Show More Authors

The present work aims to study the removal of dyes from wastewater by reverse osmosis process. Two dyes were used direct blue 6, and direct yellow. Experiments were performed with feed concentration (75 – 450 ppm), operation temperature (30 – 50 oC) and time (0.2 – 2.0 hr). The membrane used is thin film composite membrane (TFC). It was found that modal permeate concentration decreases with increasing feed concentration and time operating, while permeate concentration increases with increasing feed temperature. Also it was found that product rate increase with increasing temperature, but it decrease with increasing feed concentration and time. The concentration of reject solution showed an increase with increasing feed concentration of dyes and feed temperature, while decreases with increasing time operating of reverse osmosis unit. The maximum rejection for direct blue 6 and direct yellow are 98.89% and 98.30% respectively. The maximum recovery percentage for direct blue 6 and direct yellow are 17.84% and 18.20% respectively. The maximum concentration factor of direct blue 6 is 1.227 and for direct yellow is 1.272.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Chemical Data Collections
Removal of an anionic Eosin dye from aqueous solution using modified activated carbon prepared from date palm fronds
...Show More Authors

View Publication
Scopus (29)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Fri Apr 28 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Using Crushed Glass with Sand as a Single and Dual Filter Media for Removal of Turbidity from Drinking Water
...Show More Authors

View Publication
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Effect of Chromium (VI) on the Oxidation of Methylene Blue Dye by Fe3O4/ Chitosan Composite
...Show More Authors

     Heavy metal ion removal from industrial wastewater treatment systems is still difficult because it contains organic contaminants. In this study, functional composite hydrogels with photo Fenton reaction activity were used to decompose organic contaminants. Fe3O4 Nanoparticle, chitosan (CS), and other materials make up the hydrogel. There are different factors that affected Photo-Fenton activity including (pH, H2O2 conc., temp., and exposure period). Atomic force microscopy was used to examine the morphology of the composite and its average diameter (AFM). After 60 minutes of exposure to UV radiation, CS/ Fe3O4 hydrogel composite had degraded methylene blue (M.B.)

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Iranian Journal Of Chemistry And Chemical Engineering
The Thermal Pre-processing Technique of the Bio-waste for Contaminated Water Treatment: Histological and Experimental Study
...Show More Authors

The current study suggested a thermal treatment as a necessary proactive step in improving the adsorption capacity of bio-waste for contaminants removal in wastewater. This approach was based on the experimental and histological investigation of biowaste pods shell. This investigation showed that these shells compose of parenchyma cells that store secondary metabolites compounds produced from cells were exhibited in present study. The results also reported that these compounds are extracted directly from the cells as soon as they are exposed to an aqueous solution, hampering their use as an adsorbent material. The increase in the weight of bio-waste adsorbent at unit liquid volume increases the production of secondary metabolites compounds

... Show More
View Publication
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Statistical Analysis of the Removal of Acid Fuchsin Dye Using Zeolite 5A
...Show More Authors

Investigation of the adsorption of acid fuchsin dye (AFD) on Zeolite 5A is carried out using batch scale experiments according to statistical design. Adsorption isotherms, kinetics and thermodynamics were demonstrated.  Results showed that the maximum removal efficiency was using zeolite at a temperature of 93.68751 mg/g. Experimental data was found to fit the Langmuir isotherm and pseudo second order kinetics with maximum  removal of about 95%.  Thermodynamic analysis showed an endothermic adsorption. Optimization was made for the most affecting operating variables and a model equation for the predicted efficiency was suggested.

View Publication Preview PDF
Publication Date
Fri Aug 15 2025
Journal Name
Baghdad Science Journal
Hydrothermal synthesis of high surface area mesoporous silica as an efficient adsorbent for removal of crystal violet dye from aqueous solution
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Jul 12 2024
Journal Name
Biomass Conversion And Biorefinery
Chitosan-triphosphate/food grade algae/montmorillonite clay for adsorptive removal of methyl violet 2B dye removal: Behnken design optimization
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue May 27 2025
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Preparation, kinetics, and thermodynamic investigation of Janus green dye removal from aqueous solutions using MnO2 nanoparticles as an adsorbent
...Show More Authors

In this study, manganese dioxide (MnO₂) nanoparticles (NPs) were synthesized via the hydrothermal method and utilized for the adsorption of Janus green dye (JG) from aqueous solutions. The effects of MnO₂ NPs on kinetics and diffusion were also analyzed. The synthesized NPs were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive X-ray analysis (EDX), and Fourier-transform infrared spectroscopy (FT-IR), with XRD confirming the nanoparticle size of 6.23 nm. The adsorption kinetics were investigated using three models: pseudo-first-order (PFO), pseudo-second-order (PSO), and the intraparticle diffusion model. The PSO model provided the best fit (R² = 0.999), indicating that the adsorpti

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Heliyon
Removal of amoxicillin from contaminated water using modified bentonite as a reactive material
...Show More Authors

This study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi

... Show More
View Publication
Scopus (24)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Removal of Dissolved Trivalent Chromium Ions from Contaminated Wastewater using Locally Available Raw Scrap Iron-Aluminum Waste
...Show More Authors

The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.

The best isotherm model for the batch single Cr(III) uptake by ZVI

... Show More
View Publication Preview PDF
Crossref (12)
Crossref