Preferred Language
Articles
/
ijcpe-258
Extraction of Essential Oils from Citrus By-Products Using Microwave Steam Distillation
...Show More Authors

The main objectives of this research is to extract essential oil from: orange ( citrus sinensis), lemon( citrus limon) and mandarin( citrus reticulata) peels by two methods: steam distillation (SD) and microwave assisted steam distillation (MASD), study the effect of extraction conditions (weight of the sample, extraction time, and microwave power, citrus peel type) on oil yield and compare the results of the two methods, the resulting essential oil was analyzed by Gas Chromatography (GC).

   Essential oils are highly concentrated substances used for their flavor and therapeutic or odoriferous properties, in a wide selection of products such as foods, medicines and cosmetics. Extraction of essential oil is one of the most time and effort consuming process. Microwave-assisted extraction is a green technique for the extraction of natural products. (MASD) was better than (SD) in terms of rapidity, energy saving and yield. (MASD) gave higher yield than (SD) with shorter extraction time, yield of orange oil extracted by (MASD) was (1.150%) in (35min.) compared to (1.095%) in (45min.) by (SD) process, same results obtained for lemon and mandarin.

   The optimal microwave power was (135W) gave oil yield: (1.150%, 1.115%, 0.940%) for orange, lemon and mandarin respectively, (MASD) increased extraction temperature in short time and to a higher level compared to (SD). The optimal weight was (398.56gm) gave yield in (SD): (1.095%) and MASD (1.091%) for orange oil, same results obtained for lemon and mandarin. The best citrus peel type which gave the highest yield was orange followed by lemon then mandarin in both processes.

Limonene is the most abundant component in citrus essential oil, (GC) analysis showed that (SD) was more convenient to give high amount of limonene because of the graduate temperature rise, while in microwave extraction exposure to low microwave

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Active Alumina Extraction from Iraqi Bauxite for Catalyst's Support
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Steady State Simulation of Atmospheric Crude Distillation Tower
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Some Results on Weak Essential Submodules
...Show More Authors

Throughout this paper R represents commutative ring with identity and M is a unitary left R-module. The purpose of this paper is to investigate some new results (up to our knowledge) on the concept of weak essential submodules which introduced by Muna A. Ahmed, where a submodule N of an R-module M is called weak essential, if N ? P ? (0) for each nonzero semiprime submodule P of M. In this paper we rewrite this definition in another formula. Some new definitions are introduced and various properties of weak essential submodules are considered.

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Some Results on Weak Essential Submodules
...Show More Authors

Throughout this paper R represents commutative ring with identity and M is a unitary left R-module. The purpose of this paper is to investigate some new results (up to our knowledge) on the concept of weak essential submodules which introduced by Muna A. Ahmed, where a submodule N of an R-module M is called weak essential, if N ? P ? (0) for each nonzero semiprime submodule P of M. In this paper we rewrite this definition in another formula. Some new definitions are introduced and various properties of weak essential submodules are considered.

View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Effect of Using Microwave Radiation and H-Donors on Improving Heavy Oil
...Show More Authors

The present research has investigated the effect of microwave energy on improving the flow properties of heavy crude oil. The fragmentation of crude oil molecules was carried out with and without using 1 and 10 wt. % concentration of various types of H-donors like tetralin, cyclohexane, and naphtha.  Microwave power of 320, 385, and 540 W and radiation time 1-9 min, and temperature were studied. The kinematic viscosity and asphaltene content were measured for evaluation the improving of heavy crude oil.    Results show that viscosity of crude oil decreased with increase H-donor concentration, a maximum percentage of viscosity reduction was10.63 % for tetralin at 6 min radiation time, while 8.67%, and 7.34% for cyclohexane a

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Apr 14 2015
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
The Effect of Using Ginger (Zingiber officinale) to Prevente Salmonella typhi. in Some Food Products.: The Effect of Using Ginger (Zingiber officinale) to Prevente Salmonella typhi. in Some Food Products.
...Show More Authors

This study was conducted in order to statement the effect of ginger (Zingiber officinale) extracts in reducing the presence of the bacterium Salmonella typhimurium in some foods products.
Qualitative disclosures effective chemical compounds (alkaloids, flavonoids, phenols, tannins, terpenes) showed that the extracts of ginger an effective compounds as follows: oil extract and fresh juice> aqueous extract warm> aqueous extract cold. And studied the impact extract of fresh ginger juice, hot water ,cold water and oil rates extracts (1,2,3)% in bacteria test has shown that all s of extracts clear impact inhibition has oily extract of ginger recorded the highest value to inhibition zone reaching 35 mm when the concentration of 3%, f

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Iron from Aqueous Chloride Media in Presence of Aluminum
...Show More Authors

The extraction of iron from aqueous chloride media in presence of aluminum was studied at different kinds of extractants(cyclohexanone, tributyl phosphate, diethyl ketone), different values of normality (pH of the feed solution), agitation time, agitation speed, operating temperature, phase ratio (O/A), iron concentration in the feed, and extractant concentration]. The stripping of iron from organic solutions was also studied at different values of normality (pH of the strip solution) and phase ratio (A/O). Atomic absorption spectrophotometer was used to measure the concentration of iron and aluminum in the aqueous phase throughout the experiments.The best values of extraction coefficient and stripping coefficient are obtained under the

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
2018 15th European Radar Conference (eurad)
Delamination Detection in Glass-Fibre Reinforced Polymer (GFRP) Using Microwave Time Domain Reflectometry
...Show More Authors

View Publication
Scopus (21)
Crossref (16)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Early Childhood Special Education (int-jecse)
(𝝁∗- Essential Lifting Modules)
...Show More Authors

Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Using Texture Analysis Image Processing Technique to Study the Effect of Microwave Plasma on the Living Tissue
...Show More Authors

The present study is a hybrid method of studying the effect of plasma on the living tissue by using the image processing technique. This research explains the effect of microwave plasma on the DNA cell using the comet score application, texture analysis image processing and the effect of microwave plasma on the liver using texture analysis image processing. The study was applied on the mice cells. The exposure to the plasma is done by dividing the mice for four groups, each group includes four mice (control group, 20, 50, 90 second exposure to microwave plasma). The exposure to microwave plasma was done with voltage 175v and gas flow on 2 with room temperature; the statistical features are obtained from the comet score images and the textur

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (6)
Scopus Clarivate Crossref