Preferred Language
Articles
/
ijcpe-194
Treatment of Simulated Oily Wastewater by Ultrafiltration and Nanofiltration Processes
...Show More Authors

A study in the treatment and reuse of oily wastewater generated from the process of fuel oil treatment of gas turbine power plant was performed. The feasibility of using hollow fiber ultrafiltration (UF) membrane and nanofiltration (NF) membrane type polyamide thin-film composite in a pilot plant was investigated. Three different variables: pressure (0.5, 1, 1.5 and 2 bars), oil content (10, 20, 30 and 40 ppm), and temperature (15, 20, 30 and 40 ᵒC) were employed in the UF process while TDS was kept constant at 150 ppm. Four different variables: pressure (2, 3, 4 and 5 bar), oil content (2.5, 5, 7.5 and 10 ppm), total dissolved solids (TDS) (100, 200,300 and 400 ppm), and temperature (15, 20, 30 and 40 ᵒC) were manipulated with the help of statistical method of Taguchi in the RO process. Analysis of variable (ANOVA) and optimum condition was investigated. The study shows that pressure has the greatest impact on the flux of UF process, while temperature and pressure have similar contribution on flux of NF process. The temperature seems to have the greatest effect on TDS rejection. It was noticed that more than 96% oil removal can be achieved with flux of 624 L/m2.hr by UF process and that the fouling mechanism of UF process follows the cake/gel layer filtration model. It was observed that 100% removal of oil content can be achieved along with 79% for the TDS rejection and flux of 65 L/m2.hr by NF process. The result shows fouling in NF process follows the cake filtration model. It was concluded that the observed values are within ±5% of that the predicted which reflects a strong representative model. The treated wastewater has the characteristics that it can be reused in the process to reduce the operating cost.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 15 2005
Journal Name
Mustansiria Dental Journal
Skeletal and dental changes induced. by frankel (FR-2) apphance
...Show More Authors

Frankel appliance is one of the functional appliances used to treat Class IIskeletal cases. The aim of this stud was to evaluate the skeletal and dental changes.induced by Frankel (FR-2) appliance. Pre and post treatment cephalometric and dentalcast records of eight treated cases were analyzed. The results showed little skeletaland marked dental corrections .Maxillary incisor retraction and mandibular incisor proclination weresignificant. The increase in mandibular lane an le was ve small .The maxillary inter molar distance and mandibular inter canine and inter molardistances were increased significantly during treatment

View Publication
Crossref
Publication Date
Wed Oct 07 2026
Journal Name
Revista Iberoamericana De Psicología Del Ejercicio Y El Deporte, Issn 1886-8576, Vol. 17, Nº. 5, 2022, Págs. 269-271
The effect of a suggested rehabilitation curriculum in the treatment of partial rupture of the gluteal muscles and strengthening the working muscles of the pelvic joint in football players
...Show More Authors

Autorías: Imad Kadhim Khlaif, Israa Gameel Hussein, Talib Faissal Shnawa. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 5, 2022. Artículo de Revista en Dialnet.

View Publication Preview PDF
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Porous silicon prepared by photo electrochemical etching assisted by laser
...Show More Authors

Porous silicon (PS) layers are prepared by anodization for
different etching current densities. The samples are then
characterized the nanocrystalline porous silicon layer by X-Ray
Diffraction (XRD), Atomic Force Microscopy (AFM), Fourier
Transform Infrared (FTIR). PS layers were formed on n-type Si
wafer. Anodized electrically with a 20, 30, 40, 50 and 60 mA/cm2
current density for fixed 10 min etching times. XRD confirms the
formation of porous silicon, the crystal size is reduced toward
nanometric scale of the face centered cubic structure, and peak
becomes a broader with increasing the current density. The AFM
investigation shows the sponge like structure of PS at the lower
current density porous begi

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed May 01 2019
Journal Name
Iraqi Journal Of Science
Investigation of nanostructured and gas sensing of tin dioxide films prepared by oxidation of Sn
...Show More Authors

Publication Date
Tue Jan 01 2008
Journal Name
J Bagh College Of Dentistry
Assessment of consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite
...Show More Authors

Background: Glass ionomers have good biocompatibility and the ability to adhere to both enamel and dentin. However, they have certain demerits, mainly low tensile and compressive strengths. Therefore, this study was done to assess consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite. Materials and Methods: In this study hydroxyapatite materials were added to glass ionomer cement at different ratios, 10%, 15%, 20%, 25% and 30% (by weight). The standard consistency test described in America dental association (ADA) specification No. 8 was used, so that all new base materials could be conveniently mixed and the results would be of comparable value and the compressive strength test described by

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2025
Journal Name
Farmacia
PHARMACOGENOMIC INSIGHTS INTO PSORIASIS TREATMENT: IMPACT OF TNF-α GENE POLYMORPHISMS ON ETANERCEPT RESPONSE AND SERUM TNF-α IN IRAQI PATIENTS WITH MODERATE TO SEVERE PSORIASIS
...Show More Authors

Psoriasis is a chronic inflammatory condition that requires effective treatment. Genetic variability, particularly in the Tumour Necrosis Factor-alpha (TNF-α) gene, may influence patients’ response to biological therapies such as etanercept. This study evaluated the association of four TNF-α gene polymorphisms (rs361525 G/A, rs673 G/A, rs1800629 G/A, and rs1800750 G/A) with serum TNF-α levels and response to etanercept in Iraqi patients with psoriasis. A retrospective study was conducted on 80 patients with moderate-to-severe psoriasis who received etanercept for at least six months. Patients were categorised as responders (≥ 75% PASI reduction) or non-responders (≤ 50% PASI reduction). Genotyping was performed using PCR and

... Show More
View Publication
Scopus (1)
Scopus
Publication Date
Sun Nov 09 2025
Journal Name
Journal Of Nephropharmacology
Association between anti-erythropoietin antibody levels and treatment response in hemodialysis patients with end-stage renal disease: A cross-sectional study from Iraq
...Show More Authors

Introduction: The therapeutic efficacy of erythropoietin (EPO) may be diminished by the formation of anti-erythropoietin antibodies (AEAs), potentially resulting in therapy failure. Objectives: This retrospective study included 84 hemodialysis patients with end-stage renal disease (ESRD) treated with recombinant EPO and aimed to evaluate the association between serum AEA and treatment response. Patients and Methods: This cross-sectional study included eighty-four Iraqi patients with ESRD who had been on recombinant human EPO for more than 6 months and had hemoglobin levels below 11 g/dL. Serum AEA levels were measured in all patients to evaluate their association with treatment response and to investigate correlations with demograph

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
مجلة ميسان للدراسات الأكاديمية
Bond Strength Of 3D Printed Acrylic Resin With Silicone Soft Liner After Ethyl Acetate Surface Treatment:, A Review Of Literature
...Show More Authors

View Publication
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Sealing Depth of Q-Switched Nd:YAG 1064nm Laser in the Treatment of Patients with Hypersensitive Teeth: An In Vitro Study
...Show More Authors

The purpose of this work was to study the effects of the Nd:YAG laser on exposed dentinal
tubules of human extracted teeth using a scanning electron microscope (SEM). Eighty 2.5mm-thick
slices were cut at the cementoenamel junction from 20 extracted human teeth with an electric saw. A
diamond bur was used to remove the cementum layer to expose the dentinal tubules. Each slice was
sectioned into four equal quadrants and the specimens were randomly divided into four groups (A to D ).
Groups B to D were lased for 2 mins using an Nd:YAG laser at 6 pulses per second at energy outputs of
80 , 100 and 120 mJ. Group A served as control. Under SEM observation, nonlased specimens showed
numerous exposed dentinal tubules. SEM o

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 02 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
0.1 Second versus 0.2 Second pulse duration of Frequency Doubled Nd: YAG Laser in treatment of Clinically Significant Diabetic Maculopathy.
...Show More Authors

Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifte

... Show More