Trajectory tracking and vibration suppression are essential objectives in a flexible joint manipulator control. The flexible joint manipulator is an under-actuated system, in which the number of control actions is less than the degree of freedom to be controlled. It is very challenging to control the underactuated nonlinear system with two degree of freedom. This paper presents a hierarchical sliding mode control (HSMC) for a rotary flexible joint manipulator (RFJM). Firstly, the rotary flexible joint manipulator is modeled by two subsystems. Secondly, the sliding surfaces for both subsystems are constructed. Finally, the control action is designed based on the Lyapunov function. Computer simulation results demonstrate the effectiveness of the proposed control. The comparative study shows the proposed method has superior performance than the conventional sliding mode control by achieving the controlled objectives such as a satisfactory tracking performance and an acceptable vibration reduction for the single link flexible joint robot manipulator.
This study is conducted to determine the effect of pathogenicity of the fungus Lecanicillium lecanii in some aspects of life of the insect saw toothed beetle Oryzaephilus surinamensis L. (Coleoptera: Silvanidae) under laboratory conditions with three concentrations of spores and mildew commentator (1 × 103, 1 × 105, 1 × 107) spore / ml , on eggs and larvae second phase of the insect .The study also includs the effect of the fungus concentrations of germination on rice (jasmine) by using direct spray treatment. The results show great fungus efficiency in the control of some aspects of life of the insect, where varied efficiency depends on the concentration of spores, The highest percentage loss of eggs is 63.33% at a concentration
... Show MoreOne of the most important problems of Iraqi construction projects is the cost variances, so it is important to identify the problems and shortcomings that cause poor cost control. Through the utilization of questionnaires, the study evaluated how project costs were managed and reported. The questionnaire was distributed to 180 professionals working in the Iraqi construction sector, with a response rate of 91%. The results showed that a high percentage of projects are implemented with a difference between real and estimated costs, and the process of documenting cost data needs to be more secure. On the other hand, there is a weakness in providing the necessary work structure information to monitor costs and a lack of proc
... Show MoreThis paper is focused on orthogonal function approximation technique FAT-based adaptive backstepping control of a geared DC motor coupled with a rotational mechanical component. It is assumed that all parameters of the actuator are unknown including the torque-current constant (i.e., unknown input coefficient) and hence a control system with three motor control modes is proposed: 1) motor torque control mode, 2) motor current control mode, and 3) motor voltage control mode. The proposed control algorithm is a powerful tool to control a dynamic system with an unknown input coefficient. Each uncertain parameter/term is represented by a linear combination of weighting and orthogonal basis function vectors. Chebyshev polynomial is used
... Show MoreBACKGROUND: SARS-CoV-2 (COVID-19) is considered a highly infectious and life threatening disease. OBJECTIVE: The present paper aims to evaluate various aspects of preventive measures and clinical management of the scheduled visits for orthodontic patients to the dental clinics during the outbreak of COVID-19, and to assess how orthodontists dealt with this challenge. METHODS: Orthodontists in private and public clinics were invited to fill a questionnaire that addressed infection control protocols and concerns about clinical management of patients in the clinics during the pandemic. Frequncies and percentages of the responses were obtained and compared using Chi-square tests. RESULTS: About 77% of those working in private clinics, a
... Show MoreMultilocus haplotype analysis of candidate variants with genome wide association studies (GWAS) data may provide evidence of association with disease, even when the individual loci themselves do not. Unfortunately, when a large number of candidate variants are investigated, identifying risk haplotypes can be very difficult. To meet the challenge, a number of approaches have been put forward in recent years. However, most of them are not directly linked to the disease-penetrances of haplotypes and thus may not be efficient. To fill this gap, we propose a mixture model-based approach for detecting risk haplotypes. Under the mixture model, haplotypes are clustered directly according to their estimated d
Objective: To assess of Science Teachers' Awareness towards Communicable Diseases Control in Baghdad City
Primary Schools
Methodology: A descriptive study was conducted, included (100) primary school, (50) in Al-Rassafa sector, and
(50) in Al-Karkh sector, from March 5th 2012 to March 15th 2013, to assess of science teachers' awareness
towards communicable diseases control. A cluster sample of (100) Science teachers (males and females) were
selected, as one teacher from each school. A questionnaire format was used for data collection. The validity of
questionnaire was estimated through a penal of experts related to the field of study, and its reliability was
estimated through a pilot study conducted in (20) schools (
sensor sampling rate (SSR) may be an effective and crucial field in networked control systems. Changing sensor sampling period after designing the networked control system is a critical matter for the stability of the system. In this article, a wireless networked control system with multi-rate sensor sampling is proposed to control the temperature of a multi-zone greenhouse. Here, a behavior based Mamdany fuzzy system is used in three approaches, first is to design the fuzzy temperature controller, second is to design a fuzzy gain selector and third is to design a fuzzy error handler. The main approach of the control system design is to control the input gain of the fuzzy temperature controller depending on the cur
... Show More