Preferred Language
Articles
/
iReuP48BVTCNdQwCMmZx
DETERMINATION OF ADVANCED OXIDATIVE PROTEIN PRODUCTS LEVELS AND ITS CORRELATION WITH INFLAMMATION IN DIABETIC FOOT PATIENTS
...Show More Authors

protein oxidation through oxidative stress, which represents the overall status of the protein in the cell/tissue. Due to their increased levels of AOPPs were reported during T2DM. The aim of this study was to assess AOPP level in T2DM subjects with foot ulcer (DFU) and explore its correlation with infection. Type 2 diabetic patients (n=108) and healthy subjects (n=25) were enrolled in this study. The T2DM group was subdivided to diabetic patients without complications (n=25) and eighty-three (83) of them have diabetic foot. They were sub- grouped into two groups according to presence Osteomyelitis and abscess, and in reliance on medical analysis of WBC count and CRP. Group of diabetic without superficial or deep ulcer and no osteomyelitis or abscess G(0,1,2) (n =45), which consist patients with grades (0,1,2), and group of diabetic with deep ulcer abscess and osteomyelitis G(3,4,5)(n = 38) that consist patients with grade (3,4,5). Twenty- five (25) non-diabetic apparently healthy subjects serve as control (group C) were enrolled. The Biochemical analysis was done for all participants such as serum glucose, hemoglobin A1C, insulin, lipid profile, WBC, and C-reactive protein (CRP). Serum AOPP concentration was determined using an enzyme-linked immunosorbent assay kit. The oxidative status was assessed by measuring catalase activity, glutathione (GSH), malondialdehyde (MDA) and total thiol levels. AOPP, MDA, WBC, and CRP, were significantly higher in G (0,1,2) and G (3,4,5) groups in comparison to control group, while GSH and total thiol levels were significantly lower as compared with control group. The outcomes of this study reveal the incidence of oxidative stress among DFU patients with higher Wagner grades and the presence of relation between inflammation state in DFU subjects and oxidative stress.

Scopus
Publication Date
Thu Feb 28 2019
Journal Name
The Open Rheumatology Journal
The Value of Soluble Transferrin Receptor and Soluble Transferrin Receptor-ferritin Index in Discriminating Iron Deficiency Anaemia from Anaemia of Chronic Disease in Patients With Rheumatoid Arthritis
...Show More Authors
Background:

Anaemia is a common extra-articular manifestation of rheumatoid arthritis (RA) where anaemia of chronic disease (ACD) and iron deficiency anaemia (IDA) are the two most frequent types. The distinction between these two types of anaemia has always been challenging requiring sophisticated techniques. Serum transferrin receptor (sTfR) a truncated soluble form of the transferrin receptor is one of the parameters that is influenced by the Iron content and supply to the erythrons and is not affected by inflammatory status and therefore the use of the sTfR/log ferritin (sTfR-F) index can be a reliable indicator of functional iron deficiency.

Aim of the s
... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Mon Feb 03 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Estimation of some salivary variables and oral health status of patients with chronic myeloid leukemia aged 45-55 years
...Show More Authors

Background: Chronic myeloid leukemia is a cancer of the white blood cells characterized by the increased and unregulated growth of predominantly myeloid cells in the bone marrow. This study aimed to determine the effect of chronic myeloid leukemia on Dental caries and Oral health status including Gingivitis, Loss of attachment, Plaque index and Calculus index as well as evaluation of salivary flow rate and salivary interleukins-6 and tumor necrosis factor-?. Material and methods: Study group consisted of (75) subjects, (25) were newly diagnosed with chronic myeloid leukemia, (25) were taking medications (Glevic), and (25) were control subjects, all ag

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Applied Science Reports
Facial Acne Therapy by Using Pumpkin Seed Oil with Its Physicochemical Properties
...Show More Authors

The herbal remedy individually or in combination with standard medicines has been used in diverse medical treatises for the cure of different diseases. Pumpkin seed oil is one of the recognized edible oil and has substantial medicinal properties due to the presence of unique natural edible substances. Inflammation is an adaptive response that is triggered by noxious stimuli and conditions, which involves interactions amongst many cell types and mediators, and underlies many pathological processes. Unsaturated fatty acids (UFAs) can influence inflammation through a variety of mechanisms, and have been indicated as alternative anti-inflammatory agents to treat several inflammatory skin disorders. Pumpkin seed oil is rich in (UFAs), that its t

... Show More
Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Spectrophotometric Determination of Nifedipine in Pharmaceutical Tablets Using Batch and Flow Injection Method Via Diazotization Coupling Reaction
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
FIA– Spectrophotometric methods for the determination of Naringenin in supplements and urine samples using diazotization coupling reactions
...Show More Authors

Direct FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and u

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (82)
Crossref (72)
Scopus Clarivate Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Synthesis New Liquid Selective Electrodes of Ciprofloxacin Hydrochloride for Determination Ciprofloxacin in Pure form and Pharmaceuticals Preparation.
...Show More Authors

New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0

... Show More
View Publication Preview PDF
Scopus (8)
Scopus Crossref
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
Normal and Reverse Flow Injection- Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations Using 2, 4-Dinitrophenylhydrazine
...Show More Authors

Simple and sensitive batch and flow injection methods (normal and reverse flow injection analysis (nFIA and rFIA)) for spectrophotometric determination of vancomycin hydrochloride (VHC) in pharmaceutical preparations were proposed and optimized. Both methods are based on the oxidative - coupling reaction between vancomycin hydrochloride and 2,4-Dinitrophenylhydrazine (DNPH) in the presence of sodium periodate in alkaline medium to form a yellow water-soluble product that is stable and has a maximum absorption at 461 nm. Beer’s law was obeyed over the range of 1- 40, 0.5-120 and 0.5-150 μg.mL-1; the limits of detection were 0.537, 0.0823 and 0.233 μg.mL-1 for batch, normal and reverse flow injection methods respectively. The sampling

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering And Development
Comparison Study of (urinary & serum) AST Activity from Patients with type 2 diabetes
...Show More Authors

Aspartate aminotransferase was purified from urine and serum of patients with type 2 diabetes in a 2 steps procedure involving dialysis bag and sephadex G-25 gel filtration (column chromatography). The enzyme was purified 346.23 fold with 1467% yield and 3.46 fold with 142.85% yield in urine and serum of patients with type 2 diabetes respectively. The purified enzyme showed single peak. The results of this study revealed that AST activity of type 2 diabetes urine and serum increased significantly (p<0.001) compared with control group.