BACKGROUND: Acute coronary syndrome (ACS) is the clinical manifestation of acutely diminished coronary arterial blood supply. The rate of increase of intraventricular pressure during isovolumetric contraction (left ventricular dP/dt) represents the rate of change of pressure during ejection. OBJECTIVE: The aim of this study is to evaluate the usefulness of the rate of increase of intraventricular pressure during isovolumetric contraction (dP/dt) in assessment of left ventricular function in patients with acute coronary syndrome and its relation to certain clinical and echocardiographic features. PATIENTS AND METHODS: The study is a cross sectional study including 50 patients with an established diagnosis of acute coronary syndrome. The study was performed in Baghdad Teaching Hospital during the period between 2/2/2013 and 5/3/2014. History was taken from all patients and recoded using a specially prepared questionnaire paper. Left ventricular internal dimensions at end diastole (LVIDd) and end systole (LVIDs) were measured using M-mode echocardiography to asses left ventricular systolic function (ejection fraction). Pulse Doppler tracing of the transmitral flow velocities and tissue Doppler image (TDI) mitral annular velocities were obtained from the apical four-chamber view to assess left ventricular diastolic function. Doppler-derived dP/dt was determined from mitral regurgitation (MR) spectral flow RESULTS: The study included 50 patients (31 males and 19 females, mean age of 65.26 ± 5 years). Low dP/dt values were found in 42 patients (84%). Low dP/dt values were found more in the age group (51-60 yrs) (p value < 0.05). The mean age of patients with low dP/dt (<1000) was (65.62 ± 5yrs) and that of patients with normal dP/dt (≥ 1000) was (63.38 ± 5 yrs) with no significant difference (p value > 0.05). Low dP/dt value was significantly associated with smoking and positive family history and not significantly associated with male sex, hypertension, and diabetes mellitus. No significant association was found between low dP/dt value and type of presentation of acute coronary syndrome (p value > 0.05) or ejection fraction (p value > 0.05). It was significantly associated with LV diastolic dysfunction, left atrial size, left atrial pressure, and left ventricular size (p value < 0.05). CONCLUSION: The use of dP/dt is useful for evaluating left ventricular function in patients with acute coronary syndrome.
Abstract
In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at d
... Show MoreIn this paper, a novel coronavirus (COVID-19) model is proposed and investigated. In fact, the pandemic spread through a close contact between infected people and other people but sometimes the infected people could show two cases; the first is symptomatic and the other is asymptomatic (carrier) as the source of the risk. The outbreak of Covid-19 virus is described by a mathematical model dividing the population into four classes. The first class represents the susceptible people who are unaware of the disease. The second class refers to the susceptible people who are aware of the epidemic by media coverage. The third class is the carrier individuals (asymptomatic) and the fourth class represents the infected ind
... Show MorePorous silicon (PS) layers were formed on n-type silicon (Si) wafers using Photo- electrochemical Etching technique (PEC) was used to produce porous silicon for n-type with orientation of (111). The effects of current density were investigated at: (10, 20, 30, 40, and50) mA/cm2 with etching time: 10min. X-ray diffraction studies showed distinct variations between the fresh silicon surface and the synthesized porous silicon. The maximum crystal size of Porous Silicon is (33.9nm) and minimum is (2.6nm) The Atomic force microscopy (AFM) analysis and Field Emission Scanning Electron Microscope (FESEM) were used to study the morphology of porous silicon layer. AFM results showed that root mean square (RMS) of roughness and the grain size of p
... Show MoreBased on the needs of the scientific community, researchers tended to find new iterative schemes or develop previous iterative schemes that would help researchers reach the fixed point with fewer steps and with stability, will be define in this paper the multi_implicit four-step iterative (MIFSI) which is development to four-step implicit fixed point iterative, to develop the aforementioned iterative scheme, we will use a finite set of projective functions ,nonexpansive function and finite set from a new functions called generalized quasi like contractive which is an amalgamation of quasi contractive function and contractive like function , by the last function and a set of sequential organized steps, we will be able to prove the existen
... Show MoreThe paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.
This current research aims to identify the effectiveness of a training program in developing moral intelligence and mutual social confidence among middle school students. The researcher made a number of hypotheses for this purpose to achieve the goal of the research.
The researcher relied on the (Al Zawaida 2011) scale prepared according to Coles (1997), including (60) items, and the mutual social trust scale for (Nazmi 2001) based on Roter's theory including (38) items.  
... Show MoreThe present study aims at exploring tow cultural intelligence scales of preparatory school students. It also aims at finding out the statistically significant differences according to gender and specification. Accordingly, the present study seeks to answer the following questions:
- Is there cultural intelligence of the preparatory school students?
- Is there any statistically significant differences according to gender and specification variables?
- Is there a scale more effective than cultural intelligence scales?
The stratified random sampling method is used to for selecting the sample of (216) students of scientific and humanistic specifications from
... Show MoreThe present experimental work is conducted to examine the influence of adding Alumina (Al2O3) nanoparticles and Titanium oxide (TiO2) nanoparticles each alone to diesel fuel on the characteristic of the emissions. The size of both Alumina and Titanium oxide nanoparticles which have been added to diesel fuel to obtain nano-fuel is about 20 nm and 25 nm respectively. Three doses of (Al2O3) and (TiO2) were prepared (25, 50, and 100) ppm. The nanoparticles mixed with gas oil fuel by mechanical homogenous (manual electrical mixer) and ultrasonic processor. The study reveals that the adding of Aluminum oxide (Al2O3) and Titanium oxide (TiO2) to g
... Show MoreIn this work a hybrid composite materials were prepared containing matrix of polymer (polyethylene PE) reinforced by different reinforcing materials (Alumina powder + Carbon black powder CB + Silica powder). The hybrid composite materials prepared are: • H1 = PE + Al2O3 + CB • H2 = PE + CB + SiO2 • H3 = PE + Al2O3 + CB + SiO2 All samples related to electrical tests were prepared by injection molding process. Mechanical tests include compression with different temperatures and different chemical solutions at different immersion times The mechanical experimentations results were in favour of the samples (H3) with an obvious weakness of the samples (H1) and a decrease of these properties with a rise in temperature and the increasing
... Show More