As modern radiotherapy technology advances, radiation dose and dose distribution have improved significantly. As part of a natural evolution, there has recently been renewed interest in therapy, particularly in the use of heavy charged particles, because these types of radiation serve theoretical advantages in all biological and physical aspects. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with Breast Tissue were calculated by using Beth-Bloch equation, Zeigler's formula and SRIM software, also the Range and Liner Energy Transfer (LET) and Breast Thickness As well as Dose and Dose equivalent for this particle were calculated by using Mat lab language for (0.01-200) MeV alpha energy
Nonalcoholic fatty liver disease (NAFLD) is a common liver disease that ranges from simple steatosis to nonalcoholic steatohepatitis (NASH). So far, the underlying mechanism remains poorly understood. Here, we show that hepatic carboxylesterase 2 (CES2) is markedly reduced in NASH patients, diabetic
Breast cancer is one of the most important malignant diseases all over the world. The incidence of breast cancer is increasing around the world and it is still the leading cause of cancer mortality An Approximately 1.3 million new cases were diagnosed worldwide last year. With areas rising increasing, risk factors for breast cancer including obesity, early menarche, alcohol and smoking, environmental contamination and reduced or late birth rates become more prevalent. In Iraq, breast cancer ranks first among types of cancers diagnosed in women. This study was conducted on one hundred twenty women with breast cancer that was evaluated and investigated for the possible role of the risk factors on the development of breast cancer in females. T
... Show MoreCarbohydrate antigen 19-9 (CA 19-9) levels were measured in sera and tissues of 40 patients with breast cancer (01), 8 patients with prostate cancer (G2)and 12 patients with thyroid cancer (G3), by the enzyme linked immunosorbent assay (ELISA) technique.
The patients were admitted to Medical City Hospitals (Baghdad Teaching Hospital and Nursing Home Hospital). The sera were taken just before surgery, where the specimens were taken immediately after surgery and kept in saline solution at -20°C until the time of homogenizing process.
The results of CA 19-9 levels in sera were (16.309±7.143; 31.281±0.766;
11.5±0.707 U/ml respectively compared with serum CA 19-9 level of control group G4 which was 7.74
... Show MoreA novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.
In this study Isolated Pathogenic bacteria which causes Conjunctivitis in Children with ages between less than 3 year to17 years, admitted to Ibn Al-Haitham Eye Specialist Hospital. 102 cases were collected which include 69 Male Formed (68%) and 33 Female Formed (32%). The result of the recent study shows that the highest percentage of Male was 21% for 1113year ages and the lowest percentage was 3% for less than 3 year to 5 year ages. In Female the highest percentage was 15% for 9-11year ages and the lowest percentage was 1% for 1517year ages. In this study fifty tow isolates were identified, Gram Positive Bacteria were Predominant compared with Gram Negative Bacteria. With 32 isolates which formed (62%) whereas the number o
... Show MoreA biconical antenna has been developed for ultra-wideband sensing. A wide impedance bandwidth of around 115% at bandwidth 3.73-14 GHz is achieved which shows that the proposed antenna exhibits a fairly sensitive sensor for microwave medical imaging applications. The sensor and instrumentation is used together with an improved version of delay and sum image reconstruction algorithm on both fatty and glandular breast phantoms. The relatively new imaging set-up provides robust reconstruction of complex permittivity profiles especially in glandular phantoms, producing results that are well matched to the geometries and composition of the tissues. Respectively, the signal-to-clutter and the signal-to-mean ratios of the improved method are consis
... Show More