Thyroid hormones, triiodothyronine (T3) and thyroxin (T4) play an important role in growth, development, and physiology of the kidney. The kidney has a central role in metabolism and clearance of these hormones as well as thyroid – stimulating hormone (TSH). Chronic renal failure (CRF) is a state of irreversible deceleration in renal function results in alterations in internal milieu, which affects the synthesis and secretory rate of hormones. To evaluate the thyroid hormone levels in non-dialyzed patients with chronic renal failure (CRF); 24 patients with CRF aged 30-70 years, mean±S.d. (48.458 ± 13.569) and 48 healthy volunteers who served as controls aged 30-70 years (43.104 ± 12.387) were studied for their thyroid function status using enzyme-linked immunosorbent assay(ELISA). The study showed significant increase (p<0.05) in the serum triiodothyronine (T3), thyroxin (T4) and thyroid stimulating hormone (TSH) levels in 25%, 20%, and 25% of CRF patients respectively as compared to the healthy groups; while 75% of CRF patients showed non significant low levels (p>0.05) for both T3 and TSH and 80% for T4. Also there was a high positive relation between TSH, T3, T4 levels respectively with both age and gender of chronic renal failure patients. The results suggest that patients with CRF have a state of thyroid dysfunction.
The banking system considered as one of the most important intermediate circle between creditor and debtors it is mean the most important funding rings in economic activity, whether finance takes the a consumer or investment form and therefore it is the main base to stimulate economic activity both on the demand side, both consumption and investment and therefore of the main motivating factors for economic growth.
The banking system depends in achieve its goals on the grants and loan recovery, or what is known credit process and according to what the importance referred to the role of the banking system, it is important to ensure the safety and efficiency of the mechanisms of banking device and safety is
... Show MoreBackground: Crohn's disease (CD) is an immunological disorder associated with chronic inflammatory process of several unspecific regions of gastrointestinal tract but frequently detected in the terminal Ilium and proximal colon or both. This disease frequently presented with various oral manifestations as a consequence of inflammatory process of the disease, nutritional deficiency or medications side effects. Several therapeutic approaches have been developed for CD management that are targeting the inflammatory process and directed at controlling the host immune response. Immunosuppressants such as Azathioprine and anti-TNF α agents as well as the combination of them have been widely used as an effective therapeutic modality with a bett
... Show MorePsoriasis is a dermatological, chronic, immune-mediated condition. Psoriasis symptoms are not associated with physical burden only, but it may also have psychosocial effects on patients, diminished cognitive control, poor body image and impairments in everyday life. The value of quality of life is important since improving it is the principal goal for non-curative disease. The aim of the current study was to evaluate quality of life in a sample of Iraqi patients with psoriasis. This study is a cross-sectional study that involved 300 already diagnosed psoriasis patients who attended to the center of Dermatology and Venereology, Medical City/Baghdad. The mean age of patients was (35.156 ±10.549 years). The Arabic version of Dermatology Li
... Show MoreThe research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.
Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL
Abstract
This paper follows the growing interest and continuity of Islamic finance products worldwide, which has encouraged the formulation of financial institutions based on the concepts of Islamic Sharia in many countries of the world and is no longer limited to Islamic countries only, and Not exclusive to Muslims which is due to Islamic finance services and their ability to apply in non-Islamic societies, and perhaps what encouraged the development and progress of this industry Islamic history, which was attended by many different models With the development of trade's share between different countries as well as trips carried out by Muslims
... Show MoreSn(II) complex of the type, [Sn(SMZ)2]Cl2 was synthesized by the interaction of Sulfamethoxazole ligand and Tin Chloride, the complex was confirmed on the basis of results of elemental analyses, FT-IR, UV-Vis, molar conductance (Ëm). The elemental analysis data, suggests the stoichiometry to be 1:2 (metal: ligand) and determination of the formula of a coordination a complex formed between the Sn(II) ion and the SMZ using Job’s method of continuous variations. The study of (Ëm), indicated the electrolytic nature type 1:2. The [Sn(SMZ)2]Cl2 was screened for antibacterial activity against Gram-ve (Escherichia coli and Gram+ve (Staphylococcus aureus) and (Candida albicans) antifungal. The IR spectral data suggested that the coordination sit
... Show MoreA batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92
... Show MoreThis study was attempted to determine optimum conditions, for Glutathione s-Transferase enzyme, in sera of three groups diabetic patients type1 depending on duration of disease without complications compared with control group. The aim of this study was to find optimum conditions were determined such as (pH, Substrate Concentration, Temperature, Incubation time, Enzyme concentration, and effect of(0.15M)(0.25M) of mono divalent compounds). And to find the kinetics parameters in the three groups of diabetic patients when compared with control. It was found optimum pH(8.5,4.5,2.5,6.5).Temperatures(20cº,40cº,50cº,30cº). Incubation times (7min, 4min, 4min, 5min) substrate concentrations (12µl, 10µl, 5µl, 10µl) enzyme concentra
... Show MoreBackground: Assessment of function of the right side of the heart in cases of left ventricular dysfunction has been widely studied but the sensitive and specific echocardiographic parameter to be tested is still a matter of controversy. Right ventricular function is related to left ventricular function by ventricular independence so function of both should be assessed carefully. The objective of this study was to evaluate the effects of left ventricular systolic dysfunction on right ventricular systolic and diastolic functions and pulmonary pressure using conventional and tissue Doppler echocardiography. Patients and Methods: Sixty patients (39 males and 21 females) with heart failure due to left ventricular systolic dysfunction
... Show MoreA fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.