A simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma
... Show MoreAbstract
The study aims to identify the extent to which the applied colleges at the University of Technology and Applied Sciences meet the comprehensive quality standards in light of the national education strategy for the 2040 Vision in the Sultanate of Oman. To do this, the researchers used the descriptive approach. They used a questionnaire as a tool for data collection that was applied to (237) administrators, academics, and support functions. The study found that the extent to which the applied colleges at the University of Technology and Applied Sciences meet the comprehensive quality standards in the light of the National Education Strategy 2040 in the Sultanate of Oman recorded a high range. The study als
... Show MoreAbstract
This paper represents a study of the effect of the soil type, the drilling parameters and the drilling tool properties on the dynamic vibrational behavior of the drilling rig and its assessment in the drilling system. So first, an experimental drilling rig was designed and constructed to embrace the numerical work.
The experimental work included implementation of the drill-string in different types of soil with different properties according to the difference in the grains size, at different rotational speeds (RPM), and different weights on bit (WOB) (Thrust force), in a way that allows establishing the charts that correlate the vibration acceleration, the rate of penetration (ROP), and the power
... Show MoreIn the present study ten samples of bottled water from Baghdad conservative were taken to measure the concentration of radon gas by using nuclear track detector LR-115.The result obtained are varying from(0.033)to(0.007)pCi.l-1and these values are very low than the allowed limits (5) pCi.l-1, and specific activity from bottled water has been calculated which was vary from (0.00027)to(0.00126) Bq.l-1 and these values are very low than allowed limits (0.0123) Bq.l-1 that mean the bottled water was treated with good treatment to decrease the side effect of radon
In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma
... Show MoreThe present study deals with successive stages of productive
operations happened to produce a production within each stage befo re it moves to the next one. ll cou ld be deduced that this study is an extension to what bas been mentioned in (1 ) .ln (I), the optimum distribution of di!Terent jobs of workers and machines in the productive operations has been st ud ied whi le the study invol ves the optimum schedule for the succession of these operations presuming that thay have already been distributed on machines and workers (2).A mathematical form has been put for this study to define the "Object.ive Function "
... Show MoreA simple, sensitive, accurate and low cost effective spectrophotometric method has been developed for the determination of Tetracycline and Doxycycline in pure and pharmaceutical formulations. The method is based on the reaction of methyldopa with 4-aminoantipyren (4-AAP) in presence of potassium ferriecyanide (PFC) in an alkaline medium. Two optimization methods were applied to determine the optimum conditions of oxidizing coupling reaction variables; univariate and design of experiment (DOE) method. The conditions effecting the reaction; pH, buffer Volume, reagent concentration, oxidant concentration, type of buffer, order of addition, time of reaction and stability were optimized . Under univariate and design
... Show MoreChloroquine and Hydroxychloroquine drugs are widely prescribed for malaria disease. Since the end of 2019, humans have been under threat due to a disease called (COVID-19), which was first reported in China. Many methodical approaches have been reported to quantify chloroquine and hydroxychloroquine in blood, urine, plasma, serum, and pharmaceutical dosage form. Some of these techniques are spectrophotometry, liquid chromatography with a mass detector, gas chromatography, and ultra-performance, high-performance liquid chromatography (HPLC), in addition to electrochemical methods. This literature review discusses various analytical methods for the determining hydroxychloroquine and chloroquine.
Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e
... Show More