Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Ghrelin and Obestatin Levels as a Novel Marker in Iraqi Obese Children
...Show More Authors

Obesity is an escalating health problem in developing countries. One to ten children worldwide are overweight in a report showed by the International Obesity Task Force. Ghrelin, orexigenic peptide, has 28 amino acids, it is considered the greatest remarkable promotion in the last two decades for understanding the physiological changes of action regu­lating food intake and hunger. Obestatin is a 23-amino acid peptide nearly connected to ghrelin that secures from substitutio

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
the aspect of the radiation superposed on the soliton pulse propagated in single mode optical fiber
...Show More Authors

the first part of the research involves investigate the aspect of the radiation superposed on the one bright soliton pulse propagated on ideal single mode

View Publication Preview PDF
Publication Date
Mon Jul 25 2022
Journal Name
International Journal Of Health Sciences
Ca242 as a potential prognostic marker in colorectal cancer Iraqi patients
...Show More Authors

Background: Colorectal cancer is the third most common cancer-related mortality worldwide, and its prevalence is increasing among many nations.  Aim of the study: Investigate the predictive value of carbohydrate antigen 242 (CA242) in comparison to the CEA biomarker and to estimate the significance of CA242 as prognosis maker in colorectal cancer patients. Methods: a case-control study with a total of 150 individuals, 100 patients (59 males, 41 females) and 50 healthy controls (26 males, 24 females). using an enzyme-linked immunosorbent (ELISA) to determine the serum levels of CA242 and CEA. The study was carried out at the gastroenterology consultation clinic of the oncology teaching hospital between November 2020 and February

... Show More
View Publication
Crossref
Publication Date
Tue Mar 24 2020
Journal Name
Mintage Journal Of Pharmaceutical & Medical Sciences
CD44 AS A TUMOR MARKER DIAGNOSTIC, THE ROLE IN CANCER PROGRESSION
...Show More Authors

Publication Date
Sun Jul 01 2012
Journal Name
American Journal Of Veterinary Research
Effect of brachycephalic, mesaticephalic, and dolichocephalic head conformations on olfactory bulb angle and orientation in dogs as determined by use of in vivo magnetic resonance imaging
...Show More Authors
Abstract<p><bold>Objective</bold>—To determine the effect of head conformation (brachycephalic, mesaticephalic, and dolichocephalic) on olfactory bulb angle and orientation in dogs by use of in vivo MRI.</p><p><bold>Animals</bold>—40 client-owned dogs undergoing MRI for diagnosis of conditions that did not affect skull conformation or olfactory bulb anatomy.</p><p><bold>Procedures</bold>—For each dog, 2 head conformation indices were calculated. Olfactory bulb angle and an index of olfactory bulb orientation relative to the rest of the CNS were determined by use of measurements obtained from sagittal T2-weighted MRI images.</p><p><bold>R</bold></p> ... Show More
View Publication
Scopus (38)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparison of Estimation Sonic Shear Wave Time Using Empirical Correlations and Artificial Neural Network
...Show More Authors

Wellbore instability and sand production onset modeling are very affected by Sonic Shear Wave Time (SSW). In any field, SSW is not available for all wells due to the high cost of measuring. Many authors developed empirical correlations using information from selected worldwide fields for SSW prediction. Recently, researchers have used different Artificial Intelligence methods for estimating SSW. Three existing empirical correlations of Carroll, Freund, and Brocher are used to estimate SSW in this paper, while a fourth new empirical correlation is established. For comparing with the empirical correlation results, another study's Artificial Neural Network (ANN) was used. The same data t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Using Ultrasonic Pulse Velocity Test to Assess the Effect of Water-Cement Ratio on the Compressive Strength of Concrete
...Show More Authors

This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University.  The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The effect of triggering on the output performance of diode direct face pumping for disc laser in pulse mode
...Show More Authors

The triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Determination of time-dependent coefficient in inverse coefficient problem of fractional wave equation
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Use of Ascetic Fluid Cholesterol as a Marker to Differentiate between Types of Ascetic Fluid
...Show More Authors

Background:- Cholesterol is high in ascetic fluid due
to malignancy and other causes of exudates.
Objective:-To use cholesterol as a marker to
differentiate between exudative and transudative
ascetic fluid and to compare that with other routine
parameters.
Methods:-Twenty eight patients were included in this
study 17 females with mean age of 41.9 years, 11
males with mean age of 48.2 years. The patients were
divided in group I suspected transudate, and group II
suspected exudate according to history and clinical
examination.
Ascetic fluid samples were sent for total protein,
albumin, and cholesterol measurement blood samples
were sent for serum protein and albumin measurement.
Results:-In this

... Show More
View Publication Preview PDF