Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Effect of the documentary credit opening procedures on The obligate of time limits prescribed by the contract
...Show More Authors

This research aims to analyze the effect between letter of credit opening  and implementation procedures which considered one of the most important Foreign services submitted by bank institutions to their customers on Time contracted time limit commitment contract by some Iraqi commercial banks, descriptive analytical method used in This research The questionnaires designed a tool main research to gather information to get to know the effect ,  Seventy questionnaire forms were distributed, sixty seven forms were analyzable , The answers were analyzed by the arithmetic mean and standard deviation and test the level of influence between variables simple linear regression. The result showe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 21 2026
Journal Name
Journal Of Physical Education
A Study of Actual Training Time Administration in Bedra Specialized Weightlifting Club
...Show More Authors

View Publication
Publication Date
Mon Mar 30 2026
Journal Name
Iraqi Journal Of Science
A modified time series model using conditional and unconditional estimations with applications to a real dataset
...Show More Authors

Modern statistical techniques offer a range of methodologies for modelling time series data, with conditional and unconditional approaches providing complementary insights that enhance overall model accuracy. This article introduced a modified ARIMA model employing conditional and unconditional parameter estimates. The methodology for the new model based on novel methods is provided. The prediction process, one and two steps ahead, is covered in detail, and a novel algorithm is presented. The best model is picked based on various measurement criteria, such as coefficient of determination (R2), root mean squared error (RMSE), and mean absolute scaled error (MASE). The suggested model is applied to a monthly petrol sales dataset (Jan

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Apr 14 2024
Journal Name
Kufa Journal For Agricultural Sciences
Growth and production of three potato cultivars as affected by organic foliar nutrition
...Show More Authors

Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Preparation and Characterization of Lead Oxide Nanoparticles by Laser Ablation as Antibacterial Agent
...Show More Authors

In this work, lead oxide nanoparticles were prepared by laser ablation of lead target immersed in deionized water by using pulsed Nd:YAG laser with laser energy 400 mJ/pulse and different laser pulses. The chemical bonding of lead oxide nps was investigated by Fourier Transform Infrared (FTIR); surface morphology and optical properties were investigated by Scanning Electron Microscope (SEM) and UV-Visible spectroscopy respectively, and the size effect of lead oxide nanoparticles was studied on its antibacterial action against two types of bacteria Gram-negitive (Escherichia coli) and Gram-positive (Staphylococcusaurus) by diffusion method. The antibacterial property results show that the antibacterial activity of the Lead oxide NPs was

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (13)
Scopus Crossref
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Robotics And Control (jrc)
Design and Implementation of a Backstepping Time Varying Sliding Mode Control for the Angular Velocity Control of a Hydraulic Rotary Actuator
...Show More Authors

The Backstepping Sliding Mode Control is a control technique used for controlling nonlinear systems. In this paper, the performance of the backstepping sliding mode controller schemes for the angular velocity control for a rotary actuator of an angular velocity control system that utilizes a novel hydraulic flow control method called inlet throttling was investigated. For the angular velocity dynamic, a linear state feedback with suitable high gain is designed as the virtual controller, where steady state error can be made arbitrarily small according to the gain value. A time varying sliding variable is then selected based on the designed virtual controller. The resulting control design is robust, and the maximum error of the angular veloci

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Sep 04 2020
Journal Name
Al-kindy College Medical Journal
Association of Echocardiographic Epicardial Fat Thickness and Carotid Intima Media Thickness with the Severity of Coronary Artery Disease
...Show More Authors

Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and ablation time on the formation of aluminum nanoparticles by nanosecond laser ablation of aluminum target in ethanol
...Show More Authors

In this work we study the influence of the laser pulse energy and ablation time on the aluminum nanoparticles productivity during nanosecond laser ablation of bulk aluminum immersed in liquid.
Aluminum nanoparticles were synthesized by pulsed laser ablation of Al targets in ethanol for 3-8 minutes using the 1064 nm wavelength of a Nd:YAG laser with energies of 300-500 mJ per pulse.The laser energy was varied between 300 and 500 mJ/pulse, whereas the ablation time was set to 5 minutes. UV-Visible absorption spectra was used for the characterization and comparison of products.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Design a Fault Tolerance for Real Time Distributed System
...Show More Authors

This paper designed a fault tolerance for soft real time distributed system (FTRTDS). This system is designed to be independently on specific mechanisms and facilities of the underlying real time distributed system. It is designed to be distributed on all the computers in the distributed system and controlled by a central unit.

Besides gathering information about a target program spontaneously, it provides information about the target operating system and the target hardware in order to diagnose the fault before occurring, so it can handle the situation before it comes on. And it provides a distributed system with the reactive capability of reconfiguring and reinitializing after the occurrence of a failure.

View Publication Preview PDF
Publication Date
Mon Aug 30 2021
Journal Name
Al-kindy College Medical Journal
Diagnostic Evaluation of Uterine Artery Doppler Imaging for the Prediction of Early Abnormal Pregnancy
...Show More Authors

Objective: to assess the predictive value of Doppler imaging of the uterine artery in the identification of early intrauterine abnormal pregnancy as compared to a normal intrauterine pregnancy. Subjects and methods: one hundred and twenty pregnant ladies, at their 6-12 weeks of gestation, with a singleton pregnancy were included in this population-based case-control study. Thirty women with a missed miscarriage, 30 with hydatidiform mole, 30 with a blighted ovum, and 30 as a control group, without risk factors, underwent Doppler interrogation of the uterine arteries. Resistive index (RI), pulsatility index (PI), and the systolic/diastolic ratio (S/D) were measured for both sides. The t-test, or ANOVA test when appropriate, was

... Show More
Crossref