Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2007
Journal Name
Journal Of Economics And Administrative Sciences
The analysis of time series considers one of the mathematical and statistical methods in explanation of the nature phenomena and its manner in a specific time period.
...Show More Authors

The analysis of time series considers one of the mathematical and statistical methods in explanation of the nature phenomena and its manner in a specific time period.

Because the studying of time series can get by building, analysis the models and then forecasting gives the priority for the practicing in different fields, therefore the identification and selection of the model is of great importance in spite of its difficulties.

The selection of a standard methods has the ability for estimation the errors in the estimated the parameters for the model, and there will be a balance between the suitability and the simplicity of the model.

In the analysis of d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Impact of dome projection on operative steps during clipping of a ruptured pure posteriorly directed posterior communicating artery aneurysms
...Show More Authors

Background: Ruptured posterior communicating artery (PCoA) aneurysms are common; they usually present with subarachnoid haemorrhage (SAH) and oculomotor nerve palsy. The aneurysmal dome projection may influence the safety access and aneurysmal neck clipping. Here, we discuss additional intraoperative steps that may be required to widen the surgical field to ensure safe surgical clipping of a rupture pure posteriorly directed PCoA aneurysm. Case description: A previously healthy 38-year-old male reported sudden severe headache and disturbed level of consciousness with a Glasgow coma scale (GCS) of 13. His initial computed tomography (CT) scan of the head showed SAH in the basal cistern. 3D-constructed CT angiography (CTA) revealed a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 22 2021
Journal Name
Plos One
Awareness and preparedness of healthcare workers against the first wave of the COVID-19 pandemic: A cross-sectional survey across 57 countries
...Show More Authors
Background

Since the COVID-19 pandemic began, there have been concerns related to the preparedness of healthcare workers (HCWs). This study aimed to describe the level of awareness and preparedness of hospital HCWs at the time of the first wave.

Methods

This multinational, multicenter, cross-sectional survey was conducted among hospital HCWs from February to May 2020. We used a hierarchical logistic regression multivariate analysis to adjust the influence of variables based on awareness and preparedness. We then used association rule mining to identify relationships between HCW confidence in handling suspected

... Show More
View Publication
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Jan 20 2011
Journal Name
Journal Of Planner And Development
Architectural void is a revolution in the formation of the facades of digital architecture
...Show More Authors

Architecture has evolved through the ages as forms, relationships, materials and mechanisms according to the data of each era and up to the era of digital technology, where the change in proportions and aesthetic dimensions of contemporary architectural formation due to the capabilities of digitization has created innovative plastic properties using the void formation in the facades and the introduction of void as a formative and aesthetic element, which led to The emergence of new creative concepts and ideas that contradict traditional ideas and are consistent with the spirit of the times, led to a revolution in the world of architectural form at the level of (architectural ideas and the generation of shapes, materials and construction

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
اخفاء البیانات في الملف الصوتي من نوع موجة(wave): اخفاء البیانات في الملف الصوتي من نوع موجة(wave)
...Show More Authors

الخلاصة:
ة k تعتبر عملیة تشفیر البیانات الصوتیة من التكنولوجیا المألوفة لخزن ونقل الاشارات الصوتیة. العلامة المائی
ات k اق المعلوم k مح بالح k ذا تس k وتیة وھك k ارات الص k طة الاش k ة بواس k ات المنقول k تعطي القوة في عدم التحسس بوجود البیان
القیمة بالمحتوى مثل اسم المؤلف او الفنان او حقوق الطباعة المتعلقة بالبیانات.
ة k وع موج k ن ن k وتي م k ف ص k ي مل k ص ف k وع ن k ن ن k ة م k ة المائی k اء العلام k نة لاخف k ة محس k ث خوارز

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
A Digital-Based Optimal AVR Design of Synchronous Generator Exciter Using LQR Technique
...Show More Authors

In this paper a new structure for the AVR of the power system exciter is proposed and designed using digital-based LQR. With two weighting matrices R and Q,  this method produces an optimal regulator that is used to generate the feedback control law. These matrices are called state and control weighting matrices and are used to balance between the relative importance of the input and the states in the cost function that is being optimized. A sample power system composed of single machine connected to an infinite- bus bar (SMIB) with both a conventional and a proposed Digital AVR (DAVR) is simulated. Evaluation results show that the DAVR damps well the oscillations of the terminal voltage and presents a faster respo

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
International Journal Of Applied Engineering Research
A Proposed Method for Generating a Private Key Using Digital Color Image Features
...Show More Authors

In this paper, the goal of proposed method is to protect data against different types of attacks by unauthorized parties. The basic idea of proposed method is generating a private key from a specific features of digital color image such as color (Red, Green and Blue); the generating process of private key from colors of digital color image performed via the computing process of color frequencies for blue color of an image then computing the maximum frequency of blue color, multiplying it by its number and adding process will performed to produce a generated key. After that the private key is generated, must be converting it into the binary representation form. The generated key is extracted from blue color of keyed image then we selects a c

... Show More
Publication Date
Mon Sep 01 2008
Journal Name
Al-khwarizmi Engineering Journal
New Adaptive Data Transmission Scheme Over HF Radio
...Show More Authors

Acceptable Bit Error rate can be maintained by adapting some of the design parameters such as modulation, symbol rate, constellation size, and transmit power according to the channel state.

An estimate of HF propagation effects can be used to design an adaptive data transmission system over HF link. The proposed system combines the well known Automatic Link Establishment (ALE) together with variable rate transmission system. The standard ALE is modified to suite the required goal of selecting the best carrier frequency (channel) for a given transmission. This is based on measuring SINAD (Signal plus Noise plus Distortion to Noise plus Distortion), RSL (Received Signal Level), multipath phase distortion and BER (Bit Error Rate) fo

... Show More
View Publication Preview PDF