Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 24 2019
Journal Name
University Of Thi-qar Journal
Assessment of the Performance of Stone Columns through the Seismic Wave Test: A Review
...Show More Authors

The geophysical testing is increasingly being employed in many geotechnical applications. It is preferred in monitoring the mechanical characteristics of the ground because of its economy, not time consuming and non-destructive nature. Seismic wave test is one of the geophysical methods which showed a potential in observing the general behaviour of the reinforced soil with stone columns. Findings in most cases showed that the seismic wave measurements was integrated with or compared to the conventional tests such as standard penetration test or cone penetration test. There was a noticeable success in identifying the enhancement achieved to the ground upon the strengthening with the column, specifically when the associated surveys can produc

... Show More
View Publication Preview PDF
Publication Date
Wed May 08 2024
Journal Name
Journal Of Mathematics And Computer Science
How does media coverage affect a COVID-19 pandemic model with direct and indirect transmission?
...Show More Authors

In this paper, a compartmental differential epidemic model of COVID-19 pandemic transmission is constructed and analyzed that accounts for the effects of media coverage. The model can be categorized into eight distinct divisions: susceptible individuals, exposed individuals, quarantine class, infected individuals, isolated class, infectious material in the environment, media coverage, and recovered individuals. The qualitative analysis of the model indicates that the disease-free equilibrium point is asymptotically stable when the basic reproduction number R0 is less than one. Conversely, the endemic equilibrium is globally asymptotically stable when R0 is bigger than one. In addition, a sensitivity analysis is conducted to determine which

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Early Outcome of Bifurcational Coronary Artery Stenting
...Show More Authors

BACKGROUND : Bifurcational coronary lesions are
frequent and amounts to almost one fifth of routine
practice concerning up to 15 – 20 % of cases .
Revascularization by percutaneous coronary
intervention ( PCI ), of bifurcational lesion has
become easier by stenting yet it remains a frequent
challenge.
OBJECTIVE : To evaluate the success and hospital
complications of two most frequent technique of stent
deployment in bifurcational PCI.
METHODS : We prospectively analysed the data of
140 consecutive patients with bifurcational PCI at
Ibn_Al-Bitar Hospital for cardiac surgery for the
period from July 2008 to July 2009 .
Depending on whether the side branch was stented or
not, the patient has fa

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 01 2014
Journal Name
Pigmentary Disorders
Vitiligo: Skin Malignancies and Tumor Suppressive Marker P53
...Show More Authors

KE Sharquie, AA Noaimi, AR Bandar, SY Mohsin, Pigmentary Disorders, 2014 - Cited by 5

View Publication
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
‘Peacock tail’ Clipping Technique for a Giant Middle Cerebral Artery Aneurysm: A Technical Note
...Show More Authors

Background: Giant middle cerebral artery (MCA) aneurysms are surgically challenging lesions. Because of the complexity and variability of these aneurysms, a customized surgical technique is often needed for each case. In this article, we present a modified clip reconstruction technique of a ruptured complex giant partially thrombosed middle cerebral artery aneurysm.

Case description: The aneurysm was exposed using the pterional approach. Following proximal control, the aneurysm sac was decompressed. Then, we applied permanent clips to reconstruct the aneurysm neck. The configuration of the aneurysm mandated a tailored clipping pattern to account for resi

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Estimation the blast wave pressure effecters by apply Remote Sensing (RS) and Geographic Information System (GIS) techniques
...Show More Authors

After the year 2003 terrorist attacks knock Baghdad city capital of Iraq using bomb explosion various, shook the nation, and made public resident of Baghdad aware of the need for better ways to protect occupants, assets, and buildings cause the terrorist gangs adopt style burst of blast to injury vulnerability a wider range form, and many structures will suffer damage from air blast when the overpressure concomitant the blast wave, (i.e., the excess over the atmospheric pressure 14.7 pounds per square inch at standard sea level conditions are about one-half pound per square inch or more(
to attainment injury. Then, the distance to which this overpressure level will extend depends primarily on the energy yield (§1.20) of the burst of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Iet Colloquium On Millimetre-wave And Terahertz Engineering &amp; Technology 2015
Millimetre wave semiconductor based isolators and circulators
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Wed Dec 28 2022
Journal Name
Periodicals Of Engineering And Natural Sciences
Histological and immunohistochemical study of thyroid gland in Caucasian squirrel (Sciurus anamalus) (Gmelin, 1778) by using marker (Anti-Thyroglobulin, Code IR5090)
...Show More Authors

The current study is designed to investigate the histological and immunohistochemical characteristics of the thyroid gland in adult male Sciurus anamalus. This study found that the thyroid gland of the Caucasian squirrel is located in the neck area, below the larynx, on both sides of the trachea. It has two lobes (right and left) with cylindrical shape. The histological studies revealed that the thyroid gland is surrounded by a capsule which consists of connective tissue and forming of two layers which are outer layer and inner layer, and a layer of adipose tissue appears overlapping the outer layer. The inner tissue of the gland consists of follicles with different shapes and sizes, and is lined with simple cuboidal epithelial tissue (foll

... Show More
Publication Date
Fri Dec 02 2022
Journal Name
Periodicals Of Engineering And Natural Sciences
Histological and immunohistochemical study of thyroid gland in Caucasian squirrel (Sciurus anamalus) (Gmelin, 1778) by using marker (Anti-Thyroglobulin, Code IR5090)
...Show More Authors

The current study is designed to investigate the histological and immunohistochemical characteristics of the thyroid gland in adult male Sciurus anamalus. This study found that the thyroid gland of the Caucasian squirrel is located in the neck area, below the larynx, on both sides of the trachea. It has two lobes (right and left) with cylindrical shape. The histological studies revealed that the thyroid gland is surrounded by a capsule which consists of connective tissue and forming of two layers which are outer layer and inner layer, and a layer of adipose tissue appears overlapping the outer layer. The inner tissue of the gland consists of follicles with different shapes and sizes, and is lined with simple cuboidal epithelial tissue (foll

... Show More
Publication Date
Wed Jun 01 2011
Journal Name
Journal Of The College Of Basic Education
A Proposed Steganographic Method in Digital Media
...Show More Authors

WA Shukur, journal of the college of basic education, 2011 The aim of this research is designing and implementing proposed steganographic method. The proposed steganographic method don’t use a specific type of digital media as a cover but it can use all types of digital media such as audio, all types of images, video and all types of files as a cover with the same of security, accuracy and quality of original data, considering that the size of embedded data must be smaller than the size of a cover. The proposed steganographic method hides embedded data at digital media without any changing and affecting the quality of the cover data. This means, the difference rate between cover before hiding operation and stego is zero. The proposed steg

... Show More
View Publication