Electronic properties such as density of state, energy gap, HOMO (the highest occupied molecular orbital) level, LUMO (the lowest unoccupied molecular orbital) level and density of bonds, as well as spectroscopic properties like infrared (IR), Raman scattering, force constant, and reduced masses for coronene C24, reduced graphene oxide (rGO) C24O5and interaction between C24O5and NO2gas molecules were investigated. Density functional theory (DFT) with the exchange hybrid function B3LYP with 6-311G** basis sets through the Gaussian 09 W software program was used to do these calculations. Gaussian view 05 was em
... Show MoreDensity data of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperatures (288.15, 293.15, 298.15) k have been used to estimate the apparent molar volume (Vθ), limiting apparent molar volume (Vθ˚) experimental slope (Sv) and the second derivative of limiting partial molar volume [δ2 θ v° /δ T2] p .The viscosity data have been analyzed by means of Jones –Dole equation to obtain coefficient A, and Jones – Dole coefficient B, Free activation energy of activation per mole of solvent, Δμ10* solute, Δμ20* the activation enthalpy ΔH*,and entropy, ΔS*of activation of viscous flow. These results have been discussed
... Show MoreThere are many techniques for face recognition which compare the desired face image with a set of faces images stored in a database. Most of these techniques fail if faces images are exposed to high-density noise. Therefore, it is necessary to find a robust method to recognize the corrupted face image with a high density noise. In this work, face recognition algorithm was suggested by using the combination of de-noising filter and PCA. Many studies have shown that PCA has ability to solve the problem of noisy images and dimensionality reduction. However, in cases where faces images are exposed to high noise, the work of PCA in removing noise is useless, therefore adding a strong filter will help to im
... Show MoreDensities
ï² and viscosity
ï¨ of serine in 20, 40, and 60% (w/w) dimethyl sulfoxide (DMSO)-water mixtures were measured at 298.15, 303.15 and 308.15k. From these experimental data, apparent molal volume v ï¦ , limiting apparent molal volume v ï¦ o , the slop v S , transfer volume v ï¦ o(tr), Jones-Dole coefficients A and B were calculated. The results are
v ï¦ odiscussed the solute-solvent and solute-solute interaction, and showed that serine behaves as structure-breaker in aqueous DMSO solvent
Density data of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperatures (288.15, 293.15, 298.15) k have been used to estimate the apparent molar volume (Vθ), limiting apparent molar volume (Vθ˚) experimental slope (Sv) and the second derivative of limiting partial molar volume [δ2 θ v° /δ T2] p .The viscosity data have been analyzed by means of Jones –Dole equation to obtain coefficient A, and Jones –Dole coefficient B, Free activation energy of activation per mole of solvent, Δμ10* solute, Δμ20* the activation enthalpy ΔH*,and entropy, ΔS*of activation of viscous flow. These results have been discussed in terms of solute –solvent interaction and making/breaking ability of so
... Show MoreA Stereomicroscopic Evaluation of Four Endodontic Sealers Penetration into Artificial Lateral Canals Using Gutta-Percha Single Cone Obturation Technique, Omar Jihad Banawi*, Raghad
Background: Acute radiodermatitis is a common side effect during and after radiotherapy course in breast cancer patients treated by radiotherapy. This study assess the frequency of acute radiodermatitis and record the predictive factors for acute radiodermatitis. Patients and Methods: A descriptive case series study conducted at Baghdad, Iraq from August 2020 to September 2021. 70 female scheduled for radiotherapy sessions enrolled in this study. sociodemographic data were recorded and Skin examination before radiotherapy and weekly till the end of the radiotherapy sessions was done to report the frequency, risk factors, clinical picture and grades of acute radiodermatitis based on The National Cancer Institute’s Common Terminology Crite
... Show More