Preferred Language
Articles
/
fhdE35IBVTCNdQwCpsI5
The correlation of alveolar trabecular bone microstructure with bone density measured by cone-beam computed tomography (CBCT) and implant stability
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Correlation of Serum Lipoproteins with the Activity of Acute Lymphoblastic Leukaemia
...Show More Authors

Background: the activity of acute lymphoblastic leukemia had been observed to correlate with levels of serum lipoproteins

Objective: to evaluate the correlation of serum levels of different types of lipoproteins with activity of the disease in patients with acute lymphoblastic leukemia.

Type of the study: A prospective study.

Methods: A study included patients diagnosed as acute lymphoblastic leukemia, their serum levels of lipoproteins at time of diagnosis, and on relapse were obtained for comparison.

Results: there is significant inverse correlation of activity of acute lymphoblastic leukemia with serum total cholesterol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 05 2022
Journal Name
F1000research
Enhancement of surface properties of polyetheretherketone implant material by fractional laser texturing
...Show More Authors

Background: Polyetheretherketone (PEEK) is a promising implant material due to its superior biomechanical strength. However, due to its hydrophobic nature and lack of cellular adhesion properties, it has poor integration with bone tissue. Methods: A fractional CO2 laser was used with various parameters for surface texturing of PEEK substrate to enhance its surface properties. An optical microscope and field-emission scanning electron microscope (FESEM) were used to examine the surface morphology of untextured and laser-textured samples. Energy dispersive X-ray spectroscopy (EDX) was performed to determine the effect of the laser on the microstructure of PEEK. Surface microroughness, atomic force microscopy (AFM), and wettability were invest

... Show More
View Publication Preview PDF
Crossref (4)
Scopus Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Dental Hypotheses
Comparative Evaluation of Marginal Microleakage Between Bulk-Fill, Preheated Bulk-Fill, and Bulk-Fill Flowable Composite Resins Above and Below Cemento-Enamel Junction Using Micro-Computed Tomography: An In Vitro Study
...Show More Authors

Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil

... Show More
View Publication
Scopus (11)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Visibility of mandibular canal on CBCT cross-sectional images in comparison with panoramic radiograph: Retrospective study
...Show More Authors

Scopus (3)
Scopus
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Effect of Lanthanum Addition on the Microstructure of Mg-4Al Alloy
...Show More Authors

 This research was to determine the effect of rare earth metal (REM) on the as-cast microstructure of Mg-4Al alloy. The rare earth metal used here is Lanthanum to produce Mg-4Al-1.5La alloy. The microstructure was characterized by optical microscopy. The phases of this alloy were identified by X-ray diffraction. The microstructure of Mg-4Al consists of α-Mg and grain boundaries with precipitated phase particles. With the addition of Lanthanum, three distinct phases were identified in the X-ray diffraction patterns of the as cast Mg-4Al-1.5La:  Mg, Al11La3, Al4La. The Mg17Al12 phase was not detected. The addition of Lanthanium increases the hardness and dec

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Al-kindy College Medical Journal
The Correlation of Serum Periostin Level with Disease Severity in Patients with Covid -19
...Show More Authors

Background: Coronavirus disease 2019 (COVID-19) is an emerging zoonotic disease caused by the new respiratory virus SARS-CoV2. It has a tropism in the lung tissues where excess target receptors exist. Periostin plays a role in subepithelial fibrosis associated with bronchial asthma. Since the Coronavirus's target is the human respiratory system, Periostin has been recently described as a valuable new biomarker in the diagnosis and evaluation of disease in patients with COVID-19 lung involvement. Objectives: To assess the level of Periostin in the serum of COVID-19 patients and to correlate its role in disease severity and prognosis. Subjects and Methods: Periostin serum levels were measured for 63 patients attending three main COVID

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The accuracy of ridge mapping procedure in determining the alveolar ridge width
...Show More Authors

Background: Post-extraction alveolar ridge resorption is unavoidable phenomenon ending with insufficient ridge width. Measuring the physical dimensions of the available bone before implant surgery is an important aspect of diagnosis and treatment planning. Bone height can be calculated from radiographs, while bucco-lingual ridge width can be measured by conventional tomography, CT scanning and ridge mapping.

Radiographic techniques have certain disadvantages. Therefore the ridge mapping technique was used as an option for determining alveolar ridge width.

The purpose of this study was to compare the validity of alveolar ridge width measurements obtained with ridge mapping technique before surgical flap reflection against

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Active Vibration Control of Cantilever Beam by Using Optimal LQR Controller
...Show More Authors

Many of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.  

In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The structural and mechanical properties of ion beam
...Show More Authors

the structrual and mechanical properties of thin Ni films of different thicknesses deposited on coring glass substrate using lonbeam sputtering(IBS) technique under vacuum torr have been studied the TEM and electron

View Publication Preview PDF