Preferred Language
Articles
/
fhdE35IBVTCNdQwCpsI5
The correlation of alveolar trabecular bone microstructure with bone density measured by cone-beam computed tomography (CBCT) and implant stability
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Familial Pulmonary Alveolar Microlithiasis: A Rare Case Report with Emphasis on Imaging Findings
...Show More Authors

ABSTRACT Pulmonary alveolar microlithiasis is rare infiltrative pulmonary disease characterized by intra-alveoli deposition of microliths. We present a familial case of an adult female with complaint of progressive shortness of breath on exertion. Chest radiograph showed innumerable tiny dense nodules, diffusely involving both lungs mainly the lower zones. High-resolution CT scan illustrated widespread intra-alveolar microliths, diffuse ground-glass attenuation areas and septal thickening predominantly in the basal regions. Chest radiograph is all that is needed for the diagnosis of this case but CT scan was done to demonstrate the extent and severity of this disease

View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Visibility of mandibular canal on CBCT cross-sectional images in comparison with panoramic radiograph: Retrospective study
...Show More Authors

Scopus (3)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Al-kindy College Medical Journal
The Correlation of Serum Periostin Level with Disease Severity in Patients with Covid -19
...Show More Authors

Background: Coronavirus disease 2019 (COVID-19) is an emerging zoonotic disease caused by the new respiratory virus SARS-CoV2. It has a tropism in the lung tissues where excess target receptors exist. Periostin plays a role in subepithelial fibrosis associated with bronchial asthma. Since the Coronavirus's target is the human respiratory system, Periostin has been recently described as a valuable new biomarker in the diagnosis and evaluation of disease in patients with COVID-19 lung involvement. Objectives: To assess the level of Periostin in the serum of COVID-19 patients and to correlate its role in disease severity and prognosis. Subjects and Methods: Periostin serum levels were measured for 63 patients attending three main COVID

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Dental Hypotheses
Comparative Evaluation of Marginal Microleakage Between Bulk-Fill, Preheated Bulk-Fill, and Bulk-Fill Flowable Composite Resins Above and Below Cemento-Enamel Junction Using Micro-Computed Tomography: An In Vitro Study
...Show More Authors

Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Active Vibration Control of Cantilever Beam by Using Optimal LQR Controller
...Show More Authors

Many of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.  

In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The structural and mechanical properties of ion beam
...Show More Authors

the structrual and mechanical properties of thin Ni films of different thicknesses deposited on coring glass substrate using lonbeam sputtering(IBS) technique under vacuum torr have been studied the TEM and electron

View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Experimental Evaluation of the Strut-and-Tie Model Applied to Deep Beam with Near-Load Openings
...Show More Authors

It is commonly known that Euler-Bernoulli’s thin beam theorem is not applicable whenever a nonlinear distribution of strain/stress occurs, such as in deep beams, or the stress distribution is discontinuous. In order to design the members experiencing such distorted stress regions, the Strut-and-Tie Model (STM) could be utilized. In this paper, experimental investigation of STM technique for three identical small-scale deep beams was conducted. The beams were simply supported and loaded statically with a concentrated load at the mid span of the beams. These deep beams had two symmetrical openings near the application point of loading. Both the deep beam, where the stress distribution cannot be assumed linear, and the ex

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 01 2025
Journal Name
Saudi Medical Journal
Spectrum and classification of ATP7B variants with clinical correlation in children with Wilson disease
...Show More Authors

View Publication
Publication Date
Sun Oct 01 2023
Journal Name
History Of Medicine
Correlation of Afamin with oxidative stress in GDM
...Show More Authors

It is becoming a public health issue to predict which expectant women will develop gestational diabetes mellitus (GDM). The goal of this case control research is to investigate the role of maternal oxidative stress levels in the first, second, and third trimesters, as well as other factors, in the development of gestational diabetes mellitus (GDM). Methods Between October and December 2021, 142 women participated in this research. The 101 GDM patients were split into three groups based on their gestation (T1, T2, and T3), and 41 healthy pregnant women were chosen as the comparison group. TAS and TOS levels of oxidative stress and XO were calculated using a Spectrophotometer for colorimetric techniques; fasting and random sugar levels, as

... Show More