Background: Prolapsed intervertebral disc is an important and common cause of low backache. MRI has now become universally accepted investigation for prolapsed intervertebral disc. We, however, regularly come across situations, when MRI shows diffuse disc bulges, even at multiple levels, which cannot be correlated clinically and when such cases are operated, no significant disc prolapse is found resulting in negative exploration. Objective: To evaluate the role of M.R.I. finding not only for diagnosis of disc herniation at lumbar region but also for localization the level of herniation Methods: A prospective study on seventy five symptomatic low backache and MRI confirmed prolapsed intervertebral disc patients at lumbo-sacral region were operated on, all of the cases required excision of disc through posterior approach in knee elbow position. The time between MRI taken and surgery was two weeks, from which the data were taken in a questioner forma which include name , age ,gender , occupation , chief complaint , duration, MRI findings and intra operative finding , from June 2011 to October 2013 at Al- Kindy teaching hospital . Results: In our study 75 patients were diagnosed by clinical examination and MRI finding to have disc herniation at lumbar region . The female more than male ( 36 females , 12 males) and the ratio was 5-1, the accuracy of MRI against intra operative finding in deciding the provisional diagnosis as disc herniation was 68% .The commonest site was L4-5 disc herniation 43 patients (57.3 % ) , and L5-S1 prolapse is the next common disc herniation level 27 patient (36 % ) , L3-L4 disc herniation was two cases (2.7 %) and L4-L5 ,L5-S1 disc herniation was 3 cases (4% ). Conclusion: The most common level was L4-5 followed by L5S1.The MRI is more accurate in diagnosis of the lumbosacral disc herniation and its level in single one is more than
The brief description to the theory of propagation of electromagnetic waves in plasma was done. The cutoff and resonance regions have been showed. The principles of plasma heating at electron cyclotron resonance (ECRH) method have been mentioned. The numerical simulation to three different station: Tosca station in United Kingdom, ISX-B station in USA and T-10 station in Russia had been done. The optical depth and the friction of energy absorbed A have been calculated. The simulation results indicate that both and A are increase with size of the tokamak and it is possible to obtain full absorption in large tokamak.
Background: Nasal obstruction is common in otorhinolaryngology outpatient visitors. The diagnosis of such compliant is by history, clinical examination and diagnostic procedures. Nasal endoscopy and computerized tomography scan are common diagnostic investigations. Nasal obstruction is either anterior or posterior (nasal septal deviations, hypertrophied turbinate pathological cyst, polyps, mass etc), or postnasal obstruction (hypertrophied turbinate, adenoid hypertrophy, nasopharyngeal cyst or nasopharyngeal tumors).
Aim of study: Prospective study to compare endoscopic finding and computerized tomography of nose, paranasal sinuses and postnasal space as diagnostic methods for nasal obstruction and other nose, p
... Show MoreThis paper investigated in the numerical simulation model to calculate the Earth magnetic field components at north provinces of Najaf city (Longitude 44.316 o -44.3592o E and Latitude 32.0508o - 32.0256o N). The components of the Earth magnetic field (total intensity (F), horizontal intensity (H), declination (D), inclination (I), the north component(X), the east component(Y), and Down component(Z)) were found by using spherical harmonic world magnetic model (WMM2010). A great deal of anomaly has been discovered in all components of the Earth magnetic field at the selected region (Long. 44.345o-44.335o E, Lat.32.042o-32.032o N) using Kriging method.
... Show MoreBackground: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o
... Show MoreA LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.
Background: Most primary hypothyroidism patients also experience inefficiency and irregularity. It is possible to understand the significance of myo-inositol in treating the thyroid gland by relating it to the synthesis of thyroid hormones. Study aimed to estimate serum of inositol 1,4,5-triphosphate (IP3) in primary hypothyroidism disorder and through that level it can shed light on whether it is accused of inactivity of the thyroid gland and at the same time open the doors for the use as a treatment.
Subject and Methods: The study was taken from the analytical cross-sectional design.120 subjects were divided into three groups, the first group included 40 healthy subjects, the s
... Show More In this work a Nd:YVO4 thin disc laser setup is designed and fabricated. The disk laser system
is designed to be compact. The laser crystal was pumped by a 808 nm diode laser. The effect of input
current and pulse frequency on the output energy at pulse operation mode, and the effect of the input
current on the output power at CW mode operation are tested. At the pulsed mode, the output energy
increased linearly with the input current and decreased with pulse frequency. The threshold current
increased with increasing pulse frequency increasing. The maximum output energy from the thin disc
laser was 0.98 μJ at 1.3 kHz frequency, with 0.49A. A minimum threshold current for CW mode of
operation. The maximum outpu
Background: Coronary Artery Disease (CAD) is one of the largest causes of mortality worldwide. Clopidogrel, antiplatelet drug, has been widely used for management of CAD. The current study aimed to investigate the effect of clopidogrel on the oxidative stress in CAD patients. Methods: One hundred CAD patients, who were followed-up for 5 days after receiving clopidogrel, and 50 healthy volunteers were included in this study. Parameters include catalase (CAT), total antioxidant capacity (TAC), total oxidant capacity (TOC), total protein, albumin, and globulins were determined before and after treatment with clopidogrel. Results: CAT, TAC, and Tp were significantly decreased (P<0.0001) in CAD patients compared to healthy control and
... Show MoreGestational diabetes mellitus is glucose intolerance of varying degree with onset or first detection duringpregnancy,it can causelong and short term morbidities in both the mother and the child, such as shoulder dystocia,preeclampsia, and high blood pressure. The most powerful endogenous vasoconstrictor peptide, urotensin II, andits receptor are involved in the etiology of gestational diabetes mellitus.Aim of the study: The study’s goal was to see if there is a link between Urotensin II levels and insulin resistancein pregnant women with gestational diabetes.Patients and method: A case-control study that was conducted in obstetrics and gynecology department atBaghdad Teaching hospital from the first of January 2019 to the end of D
... Show More