This paper investigated in the numerical simulation model to calculate the Earth magnetic field components at north provinces of Najaf city (Longitude 44.316 o -44.3592o E and Latitude 32.0508o - 32.0256o N). The components of the Earth magnetic field (total intensity (F), horizontal intensity (H), declination (D), inclination (I), the north component(X), the east component(Y), and Down component(Z)) were found by using spherical harmonic world magnetic model (WMM2010). A great deal of anomaly has been discovered in all components of the Earth magnetic field at the selected region (Long. 44.345o-44.335o E, Lat.32.042o-32.032o N) using Kriging method. This anomaly can be attributed either to oil rich region or cracking in the Earth crust.
ln this paper we study and analysis the total intensity (P) .and the horizontal component (H) of the geomagnetic field at the location na ly Brazilian Anomaly (Lat 25S, long 4S·"W) in which the geomagnetic field intensity has a minimum value. We examine the relationship. between the { F , H) with altitude at a certain latitude, and
.relationship between ( F,H ) with the latitude at the certain altitude
.We study also the nature of the secular variation of the
... Show MoreTo add more details about the effect of the axial magnetic field on the plasma profile, the breakdown voltage of air was investigated at low pressure (9-15 Pa) in the presence of axial magnetic field (0.01-0.04T). The air was ignited by a DC voltage between two plain electrodes of aluminum separated by a distance (8.5cm). The measurements showed that the discharge voltage decreases to a minimum value, then returns to increase over the minimum with increasing the magnetic field strength, at all pressures in the range. It was also observed that a maximum decrease in the discharge voltage is obtained near the minimum of Paschen curve from the right side. The decrease in the discharge voltage was caused mainly by the effect of magnetic
... Show MoreThe magnetic field effect on the current-voltage characteristic curves of glow discharge in argon at low pressures has been experimentally investigated. The electrical discharge was ignited in a stainless steel tapered chamber of a nominal volume of 0.5m3 immersed inside a water-cooled coil capable of delivering a magnetic field of strength B of up to 0.42T. Three water-cooled electrodes were inserted into the chamber up to a point where their tips were 20cm away from the surface of the central column of the chamber. An enhancement of the electric field configuration within the region of the electrode assembly was performed by threading one of the electrodes with stainless circular discs(80mm and 140mm in diameter) in various forms(attac
... Show MoreFour major factories (Petroleum Refineries Company, Detergents Plant, Thermal Power Plant, and Gaseous Power Plant) are located to the north of Baiji City. They release pollutants in form of gases, liquids and solids; they find their way to the surrounding environment. To assess the environmental pollution of the area, 18 samples of surface soil distributed around the industrial establishments were collected and analyzed to determine the concentration of polycyclic aromatic hydrocarbons (PAH) components which are often targets in the environmental checking. Identification and quantification of the 16 PAHs components was accomplished using High Performance Liquid Chromatography (HPLC) had a model Shimadzu LC-10 AVP. The total concentratio
... Show MoreTo assess the environmental pollution of the soil at north Baiji City, the concentration of As, Se, Cr, Co, Cu, Cd, Sb, Mn, Mo, Ni, Pb, V, U, Sr, Ba, Ag, Rb, Li, Sn, Bi, Tl and Zn were determined in 18 sites. Results showed that the range concentrations of metal in mg/kg were Mo (0.84-2.15), Cu (17.62-78.77), Pb (9.89-19.19), Zn (39.5-374.7), Ag (0.064-0.14), Ni (90.7-210), Co (12.8-26.6), Mn (407-863), As (4-7.1), Cd (0.18-0.37), Sb (0.38-0.77), Bi (0.06-0.17), V (74-281), Cr (128-287), Li (15.3-24.4), Tl (0.14-0.24), Sn (0.6-1.7), Rb (28-51.2), U (1.2-1.5), Se (0.3-0.6), Ba (173-310), Sr (218-1270). Based on enrichment factor (EF) of trace elements, Mo, Cu, Pb, Mn, Bi, U, V, Li, Sn, Rb, Ba and Tl were showed deficiency to minimal enric
... Show More
Abstract
Due to the momentum of winning in the streets of the city of Baghdad as a result of the large number of checkpoints so felt researcher to conduct a field visit to find out the main reasons that led to this congestion and to find practical solutions to mitigate wastage winning the arrival time citizen to where you want the least possible time.
This research aims to overcome the difficulties experienced by citizens to reach their places of work and reduce waste at the time of service and waiting time as well as reduce the cost of waiting.
Has emerged study a set of conclusions, including the use of model queue (G / G / C) and the mome
... Show MoreIn this paper, 3D simulation of the global coronal magnetic field, which use observed line of sight component of the photosphere magnetic field from (MDI/SOHO) was carried out using potential field model. The obtained results, improved the theoretical models of the coronal magnetic field, which represent a suitable lower boundary conditions (Bx, By, Bz) at the base of the linear force-free and nonlinear force free models, provides a less computationally expensive method than other models. Generally, very high speed computer and special configuration is needed to solve such problem as well as the problem of viewing the streamline of the magnetic field. For high accuracy special mathematical treatment was adopted to solve the computation comp
... Show More The present study investigates the main parameters effect on the solenoid design as converging lens of charged particle beam passing through it. These parameters are solenoid magnetic field (B), solenoid radius (Ro) and the solenoid total length (L). The result indicates that the solenoid system is very sensitive to the change of these parameters. The solenoid acts as converge lens but may convert to diverging lens at some conditions. The best design obtained at (L=1100 mm, B=5000 gauss and Ro=150 mm).
This article presents test results documentation for four grouted ground anchors embedded in sandy soil. Three anchors were trial, while one was a working anchor. One trial anchor is instrumented with eight resistance-type strain gauges glued on the corrugated pipe and embedded within the grouted body. An acceptance test was made for all anchors to determine the working load. Acceptance criteria suggested by the Post-Tensioning Institute were applied, and the working anchor did not pass the creep criterion, so it was taken out of service. The strain measurements indicated that the compression stresses were generated along the free length, while the tension stresses were generated alon
Hydrocarbon production might cause changes in dynamic reservoir properties. Thus the consideration of the mechanical stability of a formation under different conditions of drilling or production is a very important issue, and basic mechanical properties of the formation should be determined.
There is considerable evidence, gathered from laboratory measurements in the field of Rock Mechanics, showing a good correlation between intrinsic rock strength and the dynamic elastic constant determined from sonic-velocity and density measurements.
The values of the mechanical properties determined from log data, such as the dynamic elastic constants derived from the measurement of the elastic wave velocities in the material, should be more a